45
February 1997
Part No. 920160 Rev A
A. To clear the error message it is necessary to either cycle the power to the Duplex Computer or enter
option 99, change the data to 3 and exit option programming. Even if the problem is corrected the fault
code will continue to be displayed until one of these procedures is executed.
TABLE 6-10. ELECTRO-MECHANICAL TOTALIZER NOT COUNTING.
Probable Cause
Corrective Action
1.
Defective Electro-Mechanical totalizer
Replace.
2.
Defective cash/credit interface board.
Replace cash/credit interface board.
3.
Defective computer.
Replace the computer assembly.
4.
Defective wiring to totalizer.
Replace harness to J7 on the cash/credit interface board.
4.
Defective wiring between cash/credit
interface board and computer.
Replace harness between J2 on cash/credit interface board
and J4 (J5) on computer.
TABLE 6-11. FAULT CODE 01.
Probable Cause
Corrective Action
Push to start switch open or cash/credit
switch shorted.
1.
Defective push to start or cash/credit
switch assembly.
Check the switch assembly and replace as necessary. See
Table 6-7., item #4.
2.
Defective switch wiring.
Check wiring harness and connectors between the suspect
switch assembly to the lighted cash/credit interface board.
Replace the wiring as necessary.
3.
Defective lighted cash/credit interface
board.
Replace the cash/credit interface board.
4.
Defective computer.
Replace the computer assembly.
TABLE 6-12. FAULT CODE 02
A
.
Probable Cause
Corrective Action
Push-button start option
disabled but switch detected.
1.
Defective wiring.
Check the two wires in the DEM which are connected to the
two wire connector at the lower left corner of the DEM
(where the push to start switch normally is connected). Repair
or replace the wiring as necessary.
2.
Defective lighted cash/credit interface
board.
Replace the cash/credit interface board.
3.
Defective computer.
Replace the computer assembly.
Содержание Dresser Vista 1 Series
Страница 1: ...1 Vista Series Blending and Non Blending Remote Dispensers SERVICE ...
Страница 4: ...Part No 920160 Rev A February 1997 ...
Страница 10: ...viii Part No 920160 Rev A February 1997 ...
Страница 12: ...2 Part No 920160 Rev A February 1997 ...
Страница 22: ...12 Part No 920160 Rev A February 1997 ...
Страница 38: ...28 Part No 920160 Rev A February 1997 ...
Страница 62: ...52 Part No 920160 Rev A February 1997 ...
Страница 76: ...66 Part No 920160 Rev A February 1997 FIGURE 7 8 NOZZLE BOOT ASSEMBLY LIFT TO START ...
Страница 77: ...67 February 1997 Part No 920160 Rev A FIGURE 7 9 NOZZLE BOOT ASSEMBLY PUSH TO START ...
Страница 83: ...73 February 1997 Part No 920160 Rev A APPENDIX A TROUBLESHOOTING FLOWCHARTS ...
Страница 110: ...100 Part No 920160 Rev A February 1997 ...
Страница 111: ...101 February 1997 Part No 920160 Rev A APPENDIX B SERVICE INFORMATION AND CONNECTOR PIN OUTS ...
Страница 128: ...118 Part No 920160 Rev A February 1997 FIGURE B 20 ISB ASSEMBLY CONNECTION PINOUTS FOR MGD Refer to Table B 1 ...
Страница 134: ...124 Part No 920160 Rev A February 1997 ...
Страница 136: ......
Страница 137: ......
Страница 138: ......
Страница 139: ......
Страница 140: ......
Страница 141: ......
Страница 142: ......
Страница 143: ......
Страница 144: ......
Страница 145: ......
Страница 146: ......