DESCRIPTION

Jet pumps are single stage domestic water pumps designed for pumping 
potable water in applications where the water is up to 90 feet below 
pump center line. A pressure switch is a standard feature. A built-in 
control valve is available on deep well pumps. Deep well pumps must 
be mounted to either a pre-charged, conventional type, or free standing 
pressure tank. A Wayne jet assembly is required (not included) for 
operation of this pump.

UNPACKING

Inspect this unit before it is used. Occasionally, products are 
damaged during shipment. If the pump or components are 
damaged, return the unit to the place of purchase for replacement, 
or call Customer Support (800-237-0987).

SAFETY SIGNAL WORDS

To help recognize this information, observe the following signal words/
hazard classifications.

  Danger indicates an imminently hazardous  

situation which, if not avoided, WILL result in death or serious injury.

  La mention Danger indique une situation 

dangereuse imminente qui, si elle n’est pas évitée, ENTRAÎNE la mort ou 

des blessures graves.

  Warning indicates a potentially hazardous  

situation which, if NOT avoided, COULD result in death or serious injury.

  La mention avertissement indique une 

situation potentiellement dangereuse qui, si elle n’est pas évitée, risque 

d’entraîner des lésions corporelles graves ou même la mort.

   Caution indicates a potentially hazardous 

situation which, if NOT avoided, MAY result in minor or moderate injury.

 

MISE EN GARDE

   La mention mise en garde indique une 

situation potentiellement dangereuse qui, si elle n’est pas évitée, 

pourrait entraîner des blessures mineures ou modérées.

  Notice indicates important information, that if  

not followed, may cause damage to equipment.

This is the safety alert symbol. It is used to alert you to potential 

bodily injury hazards. Obey all safety messages that follow this symbol 

to avoid possible harm.

NOTE: 

Information that requires special attention.

GENERAL SAFETY INFORMATION

CALIFORNIA PROPOSITION 65

T

his product can expose you to chemicals, including DEHP, 

which is known to the State of California to cause cancer, 

birth defects and reproductive harm. For more information, 

go to www.P65Warnings.ca.gov.

Ce produit peutvous exposer à des produits chimiques, 

notamment du DOP, reconnus par l’État de Californie comme 

étant cancérigènes et à l’origine d’anomalies congénitales 

et de problèmes de l’appareil reproductif. Pour plus de 

renseignements, visiter le site www.P65Warnings.ca.gov.

GENERAL SAFETY

1.  Read all manuals included with this product carefully. Be thoroughly 

familiar with the controls and the proper use of the 
equipment.   

2.  Know the pump application, limitations and potential 

hazards.

  Always install a pressure relief valve to match 

the system pressure rating and the maximum flow rate.

  TOUJOURS installer une soupape de surpression 

correspondant à la pression nominale et au débit maximal du système.

  Do not use to pump flammable or explosive 

fluids such as gasoline, fuel oil, kerosene, etc. Do not use in explosive 

atmospheres. Pump should be used to pump ONLY clear water. Failure to 

follow this warning will result in death or serious injury, and 

void warranty.

  Ne pas utiliser pour pomper des 

fluides inflammables ou explosifs tels que l’essence, le 

mazout, le kérosène, etc. Ne pas utiliser dans des environnements 

explosifs. Pomper UNIQUEMENT de l’eau claire. Le non-respect de cet 

avertissement entraînera la mort ou des blessures graves, annuler la 

garantie..

Содержание CWS Series

Страница 1: ...56 948 846 750 642 516 384 294 234 180 40 840 750 642 528 384 294 234 180 126 72 50 588 444 330 264 234 180 126 72 CWS75 3 4 30 990 906 774 630 510 408 306 246 186 54 40 780 630 510 408 306 246 186 11...

Страница 2: ...qui si elle n est pas vit e pourrait entra ner des blessures mineures ou mod r es Notice indicates important information that if not followed may cause damage to equipment This is the safety alert sy...

Страница 3: ...on annuler la garantie All wiring should be performed by a licensed or certified electrician Tout c blage doit tre r alis par un lectricien agr ou certifi 10 Make sure the line voltage and frequency o...

Страница 4: ...LLATION LOCATION Select a location as close to the water supply as possible Be sure to comply with any state or local codes regarding the placement of the pump The equipment must be protected from the...

Страница 5: ...ng air Sloping the pipe will also aid in priming the pump DRIVEN WELL FIGURE 16 PAGE 13 Drive the point several feet below the water table NOTE A packer type foot valve can be installed in the well Fi...

Страница 6: ...tall the horizontal pipe from the well to the pump Piping from the vertical well pipe to the pump should never be smaller than the well pipes 7 Slope both pipes upward toward the pump to prevent trapp...

Страница 7: ...ainst inside of the well casing It may be necessary to move the jet up and down to seat the cups 6 Install the casing adapter and the horizontal pipes 7 Slope both pipes upward toward the pump to elim...

Страница 8: ...etween the system and the house plumbing to aid in pump removal for servicing and for reducing noise transmitted to the house through the piping 4 Provide a faucet at the lowest point in the system to...

Страница 9: ...round connection must be made at this terminal Figure 9 The ground conductor must not be smaller than the circuit conductors supplying the motor The voltage of power supply must match the voltage of t...

Страница 10: ...endommager la pompe ne pas d marrer le moteur tant que la pompe n a pas t remplie d eau 1 Remove prime plug 2 Fill pump and piping completely full of water 3 Replace the prime plug 4 Close the contro...

Страница 11: ...ssurized water in the system 3 Prime the pump See Priming the Shallow Well or Priming the Deep Well Sections 4 Reconnect the power to the pump NOTE As the pump refills the tank with water the air volu...

Страница 12: ...be orientated during assembly so the two holes are on a horizontal line across the motor shaft Figure 14 18 Push the bellows side of the shaft seal over the impeller hub you can use a little water or...

Страница 13: ...or concrete to prevent cave in D DRIVEN WELL Pipe with a pointed screen is driven into the ground below the water table The depth is usually less than 50 feet Available diameters are 1 through 2 E DR...

Страница 14: ...d 5 Well screen or inlet strainer clogged 5 Clean or replace as necessary 6 Clogged nozzle deep well 6 Pull jet and clear obstruction 7 Air volume control diaphragm ruptured 7 Replace air volume contr...