background image

Please read and save these instructions. Read carefully before attempting to assemble, install, operate or maintain the product described.
Protect yourself and others by observing all safety information. Failure to comply with instructions could result in personal injury and/or
property damage! Retain instructions for future reference.

1

Description

This portable, submersible utility pump
is designed for non-automatic use in
water. The unit is equipped with a 10
ft. 3-prong grounding type power cord.
The pump’s outlet fitting is designed
for convenient discharge through a
garden hose. This pump is 

not

designed for ponds or fountains.

Unpacking

Inspect this unit before it is used.
Occasionally, products are damaged
during shipment. If the pump or
components are damaged, return the
unit to the place of purchase for
replacement. Failure to do so could
result in serious injury or death.

Very Important Safety
Information

Always follow these safety guidelines
to avoid bodily injury or property
damage.

Do not 
use to

pump flammable or
explosive fluids such as
gasoline, fuel oil, kerosene,
etc. Do not use in flammable and/or
explosive atmospheres. Pump should be
used only to pump clear water. Personal
injury and/or property damage could
result.

Risk of 
electric

shock! This pump has not
been investigated for use
in swimming pool areas.
Never place pump in pool while people
are in the water.

Do not handle

pump with wet

hands or when standing in water or on
a damp surface.

Operating Instruction and Parts Manual

GFU Series

320702-001  3/04

1. Wear safety glasses at

all times when working
with pumps.

2. It is strongly

recommended that this unit is
plugged into a Ground Fault Circuit
Interrupter (GFCI) (See 
Figure 1). Consult a local electrician
for installation and availability.

3. Do not use the power cord or

discharge hose to carry or hang the
pump, always use the handle.

Installation

Always disconnect 
the electric supply

before attempting to install, service,
relocate or perform any maintenance. If
the power source is out of sight, lock
and tag in open (off) position to
prevent unexpected power application.
Failure to do so could result in fatal
electrical shock.

Important:

This unit is not designed

for use in septic tanks or underground
vaults to pump raw sewage or
effluents. Never use in hazardous or
explosive locations.

1. This pump has been designed to

attach to a standard garden hose.
Thread the female end of the
garden hose to the male discharge
on the pump (see Figure 2) . 

2. To reduce leakage between the

pump and the hose, place a hose
washer (not included) on the hose
fitting prior to installing the hose to
the pump (see Figure 3).

3. For best performance, unwind hose

before starting the pump. Remove
kinks or bends in the hose to allow
unit to pump unrestricted (see 
Figure 4).

Submersible
Utility Pump

Figure 1

Figure 2

Female
end of
garden
hose

Figure 3

Hose Washer
(not included)

Incorrect 

Correct 

Figure 4

© 2004 Wayne Water Systems

For parts, product & service information

visit 

www.waynepumps.com

REMINDER: Keep your dated proof of purchase for warranty purposes! Attach it to this manual or file it for safekeeping.

Grounding
blade

Содержание 320702-001

Страница 1: ...face Operating Instruction and Parts Manual GFU Series 320702 001 3 04 1 Wear safety glasses at all times when working with pumps 2 It is strongly recommended that this unit is plugged into a Ground Fault Circuit Interrupter GFCI See Figure 1 Consult a local electrician for installation and availability 3 Do not use the power cord or discharge hose to carry or hang the pump always use the handle I...

Страница 2: ...ter or on a wet or damp surface Never touch the pump or discharge piping when unit is operating or fails to operate Always disconnect the pump power cord before handling Risk of electrical shock This pump is supplied with a grounding conductor and grounding type attachment plug Use a grounded receptacle to reduce the risk of fatal electrical shock Never cut off the round grounding prong Cutting th...

Страница 3: ...pe n a pas êté examinée pour l usage dans les endroits de piscines Ne jamais placer la pompe dans une piscine s il y a des personnes dans l eau Ne jamais mani puler la pompe avec les mains trempes ni si vous êtes sur un plancher trempe ou humide 1 Toujours porter des lunettes de sécurité pendant l utilisation des pompes 2 Il est recommandé que ce modèle soit branché dans un interrupteur contre le ...

Страница 4: ...t d essayer d installer de déplacer ou de procéder au service ou à l entretien Manque de suivre ces directives peut résulter en secousse électrique mortelle Cette pompe requiert le service minimal Si la pompe ne fonctionne pas procéder avec les directives de dépannage suivantes 1 Le carter de moteur de la pompe est complètement enfermé et ne requiert pas de service Le démontage du carter de moteur...

Страница 5: ...l uso de esta bomba en piscinas Jamás introduzca la bomba en una piscina cuando haya gente en el agua No manipule la bomba con las manos húmedas o estando parado en el agua o una superficie húmeda 1 Use anteojos de seguridad cada vez que trabaje con bombas 2 Se recomienda enfáticamente que se enchufe esta unidad en un tomacorriente con interruptor de circuito de pérdida a tierra ver Figura 1 Consu...

Страница 6: ...e una bomba o motor de bomba con las manos mojadas o cuando esté parado en el agua o en una superficie húmeda Nunca toque la bomba o la tubería de descarga cuando la unidad esté operando o cese de operar Desconecte siempre el cordón de energía de la bomba antes de manipular Hay riesgo de choque eléctrico Esta bomba está provista de un conductor y un enchufe con conexión a tierra Utilice un tomacor...

Страница 7: ...7 Operating Instructions And Parts Manual Instructions D Utilisation Et Manuel De Pièces Manual de Instrucciones de Operación y Partes www waynepumps com Notes Notes Notas ...

Страница 8: ...c ne pas s appliquer Cette garantie limitée donne à l acheteur des droits légaux précis et vous pouvez avoir d autres droits légaux qui varient d une Province ou d un État à l autre En aucun cas soit par suite d une rupture de contrat de garantie acte dommageable y compris la négligence ou autrement ni Wayne ni ses fournisseurs ne seront tenus responsables pour aucun dommage spécial indirect ou pé...

Отзывы: