![Wayne 3/VISTA series Скачать руководство пользователя страница 55](http://html1.mh-extra.com/html/wayne/3-vista-series/3-vista-series_service-manual_878416055.webp)
51
June 2001
Part No. 920525 Rev A
F25 - Local Preset By Button Configuration
Sub-function numbers are in the format .0X where X = the selected configuration parameters defined as follows:
.00
Preset button #1 operation mode
1 = Money
2 = Volume
.01
Preset button #2 operation mode
1 = Money
2 = Volume
.02
Preset button #3 operation mode
1 = Money
2 = Volume
.03
Preset button #1 money/volume limit, 0-999999
.04
Preset button #2 money/volume limit, 0-999999
.05
Preset button #3 money/volume limit, 0-999999
F26 - VAP Configuration
Sub-function numbers are in the format .0X where X = the selected configuration parameters defined as follows:
.00 ORVR
control
1 = Enabled
2 = Disabled
F27 - Side A Dispenser Configuration
.00
Button input for Local Authorize function, 0-8, where 0 = not supported
F28 - Side B Dispenser Configuration
.00
Button input for Local Authorize function, 0-8, where 0 = not supported
F29 - Side A Liter Flow Rate Configuration
.0N
Maximum slow flow rate, 3-50 (units of 1/10 Liters/min.)
.1N
Minimum slow flow rate, 0-50 (units of 1/10 Liters/min.), 0 = no minimum
.2N
Maximum fast flow rate, 10-180 (units of Liters/min.)
.3N
Minimum fast flow rate, 0-180 (units of Liters/min.), 0 = no minimum
N
Logical nozzle
F30 - Side B Liter Flow Rate Configuration
.0N
Maximum slow flow rate, 3-50 (units of 1/10 Liters/min.)
.1N
Minimum slow flow rate, 0-50 (units of 1/10 Liters/min.), 0 = no minimum
.2N
Maximum fast flow rate, 10-180 (units of Liters/min.)
.3N
Minimum fast flow rate, 0-180 (units of Liters/min.), 0 = no minimum
N
Logical nozzle
F31 - Side A Gallon Flow Rate Configuration
.0N
Maximum slow flow rate, 1-10 (units of 1/10 Gallons/min.)
.1N
Minimum slow flow rate, 0-10 (units of 1/10 Gallons/min.), 0 = no minimum
Содержание 3/VISTA series
Страница 1: ...S E R V IC E 3 Vista Series Blending and Non Blending Dispensers ...
Страница 3: ...June 2001 Part No 920525 Rev A 3 Vista Series Blending and Non Blending Dispensers Service ...
Страница 4: ...Part No 920525 Rev A June 2001 ...
Страница 13: ...9 June 2001 Part No 920525 Rev A 3 BOARD LAYOUTS INDICATORS AND PINOUTS ...
Страница 27: ...23 June 2001 Part No 920525 Rev A FIGURE 3 1 COMPUTER BOARD ...
Страница 28: ...24 Part No 920525 Rev A June 2001 FIGURE 3 2 ISB BOARD ASSY ...
Страница 29: ...25 June 2001 Part No 920525 Rev A FIGURE 3 3 RELAY BOARD ...
Страница 30: ...26 Part No 920525 Rev A June 2001 FIGURE 3 4 24VOLT DIST BOARD ...
Страница 31: ...27 June 2001 Part No 920525 Rev A FIGURE 3 5 WAYNE VAC CONTROL BOARD ...
Страница 32: ...28 Part No 920525 Rev A June 2001 FIGURE 3 6 DUAL CAT BOARD ...
Страница 33: ...29 June 2001 Part No 920525 Rev A ...
Страница 34: ...30 Part No 920525 Rev A June 2001 ...
Страница 36: ...32 Part No 920525 Rev A June 2001 ...
Страница 44: ...40 Part No 920525 Rev A June 2001 ...
Страница 74: ...70 Part No 920525 Rev A June 2001 ...
Страница 75: ...71 June 2001 Part No 920525 Rev A 8 PROCEDURES FOR UPLOADING AND DOWNLOADING FILES ...
Страница 76: ...72 Part No 920525 Rev A June 2001 FIGURE 8 1 SERVICE TERMINAL SCREENS THAT APPEAR ON THE LAPTOP ...