31
June 2001
Part No. 920525 Rev A
4. MECHANICAL PARTS
4.1.
NOZZLE BOOT (PROXIMITY “REED” SWITCH STYLE BOOT)
The nozzle boot assembly, used on the dispenser models covered in this manual, uses a
proximity “Reed” switch and magnet for ON/OFF dispenser activation. The nozzle boot
can be assembled in either the Lift-to-Start or the Push-to-Start configuration.
4.1.1.
Lift-to-Start Version
The nozzle boot switch assembly (see section 10) consists of a proximity reed
switch attached to the rear of the nozzle boot casting. A magnet is contained in
the Lift-to-Start lever and when the lever is lifted to the ON position the magnet
is brought into alignment with the proximity switch, turning the switch ON.
There is no adjustment for the switch.
Check the operation of the nozzle switch as follows:
1. Authorize the dispenser and remove the nozzle from the nozzle boot. Lift
the nozzle hook lever fully upward to make sure the switch turns ON. An
ON switch will be indicated by the unit price displays of the unselected
products going OFF or displaying dashes.
2. Lower the Lift-to-Start lever to the down position and check that the switch
turns OFF. An OFF switch is indicated by the unit price displays of the unse-
lected products coming back ON.
4.1.2.
Push-to-Start Version
The nozzle boot switch assembly (see section 10)) consists of a proximity reed
switch attached to the side of the nozzle boot casting and a magnetic actuator
shaft inserted into a spring-loaded flipper within the nozzle boot. When the
nozzle is removed, the flipper rotates and aligns the magnetic shaft with the
proximity switch, turning the switch ON. There is no adjustment for the switch.
Check the operation of the nozzle switch as follows:
1. Authorize the dispenser and remove the nozzle from the nozzle boot to
make sure the switch turns ON. An ON switch will be indicated by the
lighted Push-to-Start buttons and the unit price displays blinking.
2. Insert nozzle slowly into the nozzle boot and check that the switch turns
OFF. An OFF switch is indicated by the lighted Push-to-Start buttons
turning OFF and the unit price displays stop blinking.
Содержание 3/VISTA series
Страница 1: ...S E R V IC E 3 Vista Series Blending and Non Blending Dispensers ...
Страница 3: ...June 2001 Part No 920525 Rev A 3 Vista Series Blending and Non Blending Dispensers Service ...
Страница 4: ...Part No 920525 Rev A June 2001 ...
Страница 13: ...9 June 2001 Part No 920525 Rev A 3 BOARD LAYOUTS INDICATORS AND PINOUTS ...
Страница 27: ...23 June 2001 Part No 920525 Rev A FIGURE 3 1 COMPUTER BOARD ...
Страница 28: ...24 Part No 920525 Rev A June 2001 FIGURE 3 2 ISB BOARD ASSY ...
Страница 29: ...25 June 2001 Part No 920525 Rev A FIGURE 3 3 RELAY BOARD ...
Страница 30: ...26 Part No 920525 Rev A June 2001 FIGURE 3 4 24VOLT DIST BOARD ...
Страница 31: ...27 June 2001 Part No 920525 Rev A FIGURE 3 5 WAYNE VAC CONTROL BOARD ...
Страница 32: ...28 Part No 920525 Rev A June 2001 FIGURE 3 6 DUAL CAT BOARD ...
Страница 33: ...29 June 2001 Part No 920525 Rev A ...
Страница 34: ...30 Part No 920525 Rev A June 2001 ...
Страница 36: ...32 Part No 920525 Rev A June 2001 ...
Страница 44: ...40 Part No 920525 Rev A June 2001 ...
Страница 74: ...70 Part No 920525 Rev A June 2001 ...
Страница 75: ...71 June 2001 Part No 920525 Rev A 8 PROCEDURES FOR UPLOADING AND DOWNLOADING FILES ...
Страница 76: ...72 Part No 920525 Rev A June 2001 FIGURE 8 1 SERVICE TERMINAL SCREENS THAT APPEAR ON THE LAPTOP ...