INSTALLATION MANUAL

Figure 3: Effl uent Pump in Septic Tank

1.  This installation must be in accordance with the National 

Electric Code and all applicable local codes and ordinances.

2.  For sump applications, follow typical sump installation 

instructions. For effl uent applications, continue to step 3.

3.  Clean the basin of all debris. 

4.  Set the pump on a solid, level surface.  Do not place pump 

directly on clay, earth, gravel or sand.  A brick or block may 
be installed under the pump to provide a solid base.

5.  Verify the fl oat switch has at least 1 inch clearance to the 

side wall of the basin and is free to move throughout its 
movement.

6.  If optional control device or fl oat is used, follow mounting 

instruction supplied with device or fl oat. 

7.  Install discharge plumbing according to local, regional and 

state codes.  Do not reduce the discharge pipe size below 
that which is provided on the pump.

8.  Drill a 1/8 in. “weep” hole in the discharge pipe 1 in. 

above the pump discharge.  Water stream will be visible 
from the hole when the pump is running.  The hole must 
be cleaned periodically.

9.  Install a union to allow easy removal of the pump for 

cleaning and service.    

10.  Install a check valve (required) to prevent back-fl ow.  It 

should be installed above the union.  

11.  A gate valve or ball valve should be installed above the 

check valve as required by local, regional or state codes.

12.  Connect remaining discharge pipe.  The remainder of 

the discharge line should be as short as possible with a 
minimum number of turns.

13.  Secure cords to discharge pipe to prevent possible 

switch entanglement. Use cable or zip ties to secure the 
power cords. 

14.  Connect pump power supply cord to a properly grounded 

receptacle.

15.  Fill the basin with water. The pump will start when the 

water level has reached the switch-on level.  Verify the 
pump is operating normally.

16. Install cover

TYPICAL EFFLUENT INSTALLATION

1.  Discharge Outlet Pipe

7.  Septic Tank

2. Junction 

Box

8. Effl uent Pump

3.  Pump/Switch Wires

9.  Brick or Block

4. Union

10. 

Discharge 

Pipe

5. Effl uent Inlet Pipe

11.  Check Valve

6. Switches

1

3

4

6

9

2

10 11

8

7

5

Printed on 100% Recycled Paper

Содержание 200000-015

Страница 1: ...ected with a ground fault circuit interrupter GFCI All wiring must be performed by a qualified licensed electrician and comply with the National Electric Code and all applicable local codes and ordina...

Страница 2: ...debris that could interfere with the operation of the switch IT IS RECOMMENDED TO USE A CHECK VALVE with this pump to prevent the back flow of fluid after each pump cycle DO NOT INSTALL OR OPERATE TH...

Страница 3: ...undation so any remaining water will drain away and not freeze 3 TYPICAL SUMP INSTALLATION 1 This installation must be in accordance with the National Electric Code and all applicable local codes and...

Страница 4: ...discharge Water stream will be visible from the hole when the pump is running The hole must be cleaned periodically 9 Install a union to allow easy removal of the pump for cleaning and service 10 Ins...

Страница 5: ...ng instruction supplied with device or float 9 Install a sealed basin cover to prevent debris from falling into the basin personal injury and contain gases and odors 10 A union should be installed abo...

Страница 6: ...protector and may restart unexpectedly Protector tripping is an indication of motor overloading as a result of operating the pump at low heads excessively high or low voltage inadequate wiring incorre...

Страница 7: ...g available at local hardware stores to isolate pump vibration from discharge plumbing Pump will not shut off 1 Switch 2 Switch obstructions 3 Restricted discharge obstruction in piping 4 Excessive in...

Страница 8: ...8 NOTES INSTALLATION MANUAL Printed on 100 Recycled Paper...

Страница 9: ...S CURIT la prise de courant doit tre prot g e avec un disjoncteur de fuite la terre DDFT Tout le c blage doit tre effectu par un lectricien qualifi et se conformer au code national de l lectricit des...

Страница 10: ...UTILISER UN CLAPET DE NON RETOUR avec cette pompe pour pr venir le retour d eau de liquide apr s chaque cycle de pompe NE PAS INSTALLER NI FAIRE FONCTIONNER LA POMPE SI ELLE A T ENDOMMAG E DE TOUTE F...

Страница 11: ...plac sur une pente vers le bas loin de la fondation pour que l eau restante se draine au lieu de geler 11 INSTALLATION TYPIQUE DE PUISARD 1 Cette installation doit tre conforme au Code national d lect...

Страница 12: ...ent 9 Installer un raccord union pour permettre d enlever facilement la pompe pour le nettoyage et l entretien 10 Installer un clapet de non retour requis pour viter tout retour d eau Il doit tre inst...

Страница 13: ...cuvette scell e pour emp cher les d bris d y tomber pr venir les blessures et contenir le gaz et les odeurs 10 Un raccord union doit tre install au dessus de la cuvette pour permettre d enlever facil...

Страница 14: ...pourrait red marrer de mani re impr vue Le d clenchement du protecteur est une indication de surcharge du moteur suite l op ration de la pompe faible hauteur de chute tension excessivement haute ou ba...

Страница 15: ...pas 1 Interrupteur d fectueux 2 Obstruction d interrupteur 3 D charge obstru e obstruction dans la tuyauterie 4 Entr e excessive ou pompe non pas de la taille appropri e pour l application 1 Remplacer...

Страница 16: ...16 NOTES MANUEL D INSTALLATION Printed on 100 Recycled Paper...

Страница 17: ...URIDAD el tomacorriente debe ser protegido con un interruptor de descarga a tierra GFCI Todo el alambrado debe ser realizado por un electricista autorizado y calificado y debe cumplir con los C digos...

Страница 18: ...A EL USO DE UNA V LVULA DE RETENCI N con esta bomba para prevenir el reflujo de l quido despu s de cada ciclo de la bomba NO INSTALE NI HAGA FUNCIONAR LA BOMBA SI HA SIDO DA ADA DE CUALQUIER MANERA NO...

Страница 19: ...ientos para que toda agua restante escurra y no se congele 19 INSTALACI N T PICA DE SUMIDERO 1 Esta instalaci n debe realizarse de acuerdo con los C digos el ctricos nacionales y todos los c digos y o...

Страница 20: ...jero El agujero debe limpiarse peri dicamente 9 Instale una uni n para facilitar el retiro de la bomba para limpieza y servicio 10 Instale una v lvula de retenci n requerida para prevenir el reflujo D...

Страница 21: ...n el dispositivo o flotador 9 Instalan una tapa de pileta con sello para impedir la ca da de residuos en la pileta lesiones personales y para contener gases y olores 10 Debe instalarse una uni n arrib...

Страница 22: ...ndica una sobrecarga del motor debido a que la bomba est funcionando con cargas bajas baja restricci n de descarga voltajes excesivamente altos o bajos un cableado inadecuado condiciones incorrectas d...

Страница 23: ...l espiral limpie y o reemplace el impulsor La bomba no se apaga 1 Interruptor defectuoso 2 Obstrucci n del interruptor 3 Descarga restringida obstrucci n en la tuber a 4 Demasiado flujo de entrada o l...

Страница 24: ...24 NOTAS MANUAL DE INSTALACI N Printed on 100 Recycled Paper...

Отзывы: