About This Manual

The intent of this manual is to help you in two ways: to provide you with step-by-step instructions for quick and
easy assembly of your product, and to serve as a reference for simple maintenance and questions you may
have regarding your product.

Read ALL instructions carefully before starting your WayCool®. Pay particular attention to all SAFETY
information.

Optional equipment contains necessary instructions for assembly and/or operation.

The WayCool® evaporative cooler is labeled with a serial number. The serial number is located 
inside the unit on the aluminum frame, behind the switch. Removal of the serial number label will 
void all warranties.

All information, illustrations and specifications in this manual are based on the latest product information
available at the time of printing. Product specifications subject to change. We reserve the right to make changes
at any time without notice.

Safety Information

4

Using the equipment for purposes other than specified in this manual may cause personal injury and/or damage
to the equipment.

Safety Alert Symbol

This is a safety alert symbol. When you see this symbol on your equipment, be alert to the potential
for personal injury. This equipment is designed to be installed and operated as safely as possible;
however, hazards do exist.

Signal Words

are used in conjunction with the safety alert symbol to identify the severity of the warning.

CAUTION

indicates an imminently hazardous situation, which, if not avoided, COULD cause damage to your

equipment or equipment failure.

WARNING

indicates a potentially hazardous situation, which, if not avoided, COULD result in death or serious

injury.

Warning and Danger Decals 

have been placed on the equipment to warn of potentially dangerous situations.

Care should be taken to keep this information intact and easy to read at all times. Replace missing or damaged
safety decals immediately. The diagram below shows the proper location of the safety decals as shipped from
the factory.

WARNING!

Interference with the oscillating spout while the unit is operating,
or manually directing the oscillating spout, will cause damage to
the gear motor. Keep oscillating path clear of obstructions.

This warning decal is
found on the top of
oscillating units only.

Start Unit 

-Turn water pump on 5-10

minutes before running blower to wet
evaporative cooling pads.

Shut Down

-Turn pump off and run only

blower until evaporative cooling pads are dry.
This prolongs the life of the pads.

WARRANTY- VOID IF YOU RUN THE
PUMP WITHOUT WATER.

CAUTION - ALWAYS TURN OFF AT
SWITCH AND DISCONNECT POWER
BEFORE REMOVING EVAPORATIVE
COOLING PADS FOR CLEANING OR
INTERNAL MAINTENANCE.

CLEANING 

- Clean pads a minimum of once

every two weeks. Remove pads from unit
and clean with garden hose only. DO NOT
use chemicals or high pressure hose.

netzerotools.com

netzerotools.com

Содержание WC-1HPMFAOSC

Страница 1: ...Portable Evaporative Cooler WayCool 1HP MFA Series USER S MANUAL WC 1HPMFA WC 1HPMFA360 WC 1HPMFAOSC WCG 1HPMFA netzerotools com netzerotools com netzerotools com ...

Страница 2: ...r WCG 1 HPMFA 220 Waycool Evaporative Cooler 220 V Schaefer WC 1 HPMFA 220 Waycool Evaporative Cooler 220 V Schaefer WC 1 HPMFA 360 Waycool Evaporative Cooler Schaefer WCG 1HPMFAOSC Waycool Evaporative Cooler Schaefer WC 1 HPMFAOSC Waycool Evaporative Cooler Schaefer WCG 1HPMFA Waycool Evaporative Cooler Schaefer WC 1HPMFA Waycool Evaporative Cooler netzerotools com netzerotools com ...

Страница 3: ...4 Scale buildup 14 Splattering in front 14 Leaking from the bottom 14 OPTIONS AND ACCESSORIES 15 Pneumatic wheels 15 Water conditioner and cleaner 15 Air filters 15 Aluminum grates 15 Oscillating spout 16 WARRANTY 17 Table of Contents 2 Using this equipment for any other purpose than it was intended or in a way not within the operating recommendations specified in this manual will void the warrant...

Страница 4: ...an evaporative cooler the cellulose cooling pads take the place of your skin water instead of perspiration wets them and a fan moves the air The air blows across the cooling pads and evaporates moisture Heat is drawn from the pads and the air dropping the air temperature and producing the cooling effect The cooled air is then forced through a building or space and displaces the warm air out of bui...

Страница 5: ...re used in conjunction with the safety alert symbol to identify the severity of the warning CAUTION indicates an imminently hazardous situation which if not avoided COULD cause damage to your equipment or equipment failure WARNING indicates a potentially hazardous situation which if not avoided COULD result in death or serious injury Warning and Danger Decals have been placed on the equipment to w...

Страница 6: ... gloves when you reach under the frame to inspect the PVC pipes and mesh socks A GFCI Ground Fault Circuit Interrupter is recommended for use with this product If pads and grates are removed for servicing they must be replaced prior to operating the unit Specifications Height and Width 33 x 33 wide x 54 high with casters and directional spout Shipping Weight 225 pounds Blower double inlet centrifu...

Страница 7: ... blower is hung from the top of the frame and powered by a belt driven 1HP electric motor The blower draws room air through the cooling pads where it picks up moisture and cools by evaporation The blower then discharges the cooled air through the spout It is important the cooled space has sufficient air openings so the warmer air can flow out and be replaced by the cooled air A closed in space or ...

Страница 8: ...so be filled manually with a hose or bucket if a hose connection is impractical Simply remove the cap and pour the water directly into the reservoir When you fill the reservoir manually it can be filled to a higher level but be sure to watch the fill gauge to avoid overfilling and flooding Water Supply System 7 Actual WayCool may vary slightly from unit shown here Fill pipe and cap Water gauge Man...

Страница 9: ...ter flow to the cooling pads is reduced and performance decreases The clear filter housing is threaded and screws into the filter body for easy removal to access the screen A dirty water supply will quickly reduce the unit s performance and the unit will require more frequent cleaning to maintain cooling effectiveness Always try to use a filtered treated water supply A clear vinyl hose connects th...

Страница 10: ...un the unit with the plastic retaining grates in place and handle them carefully when you clean them Crushed cells reduce the total airflow through the unit and therefore lowers its cooling capacity The cooling pad sections two sections per side eight sections total are held by metal channels at the top and bottom of the unit The channels hold the cooling pads in position and form four sidewalls t...

Страница 11: ...uire lubrication A belt tensioner is connected to a bracket on the motor A rubber foot at one end rests against the blower bracket that is attached to the blower casing When the locking nut is backed off the bolt can be turned in to tighten the V belt or backed out to loosen or remove the V belt Do not over tighten the V belt as you can prematurely wear out the bearings The power cord runs down th...

Страница 12: ...cooling pads then switch to LOW COOL or HIGH COOL to begin cooling Control Switch 11 Operation and Maintenance UNIT PLACEMENT AND OTHER CONSIDERATIONS The WayCool should be placed at one end of the building and an appropriate exhaust fan should be at the opposite end to pull the cool air from the WayCool and discharge the warm air out of the building Try to get all the air flowing in the same dire...

Страница 13: ...s inside your other hand on the outside and lifting the pad up and out from the bottom 6 Inspect the entire unit for shipping damage 7 Ensure the fan belt is attached to the motor and blower pulleys and that the belt tension is correct To ensure it is correct press your finger on the belt about halfway between each pulley It should have about 1 2 of play If it is too loose the V belt will slap aro...

Страница 14: ...there are no obstructions that could disrupt or block the airflow Make sure the unit is level at all times Keep the unit at least three feet away from walls or other obstructions that will interfere with airflow into the unit 2 Check the drain cap to be sure it is in place and secure 3 Connect the garden hose to the brass hose adapter Be sure there is a washer in the female end of the hose connect...

Страница 15: ...it 5 Remove the top cover and set it aside 6 Locate the four PVC pipes in the top metal channel Each PVC pipe is secured to the Y connector by a single screw Remove this screw from all four PVC pipes 7 Grip the opposite end of each PVC pipe with pliers and gently twist it out of its Y connector 8 Remove the plastic mesh socks from the PVC pipes and clean them in warm soapy water 9 Direct a jet of ...

Страница 16: ...n some water sources Place the tab under the float valve water outlet for fast effictive odor control Place the tab next to the pump for longer lasting odor control CLEANER WayCool cleaner is recommended to remove scale buildup from the water supply system Follow the instructions on page 13 to clean the unit Refill with water and add one pint of Cooler Cleaner Treatment to the reservoir Operate th...

Страница 17: ...OUT APPEARS TO JUMP WHILE OSCILLATING 1 The spout may be fastened too tight against the top of the WayCool The nut above the brace should be loosened to allow 1 16 clearance between the bottom of the spout and the top of the WayCool 2 If the spout is not too tight the linkage may be damaged Look for visible damage to the linkage rod or the lever If any of the linkage parts are damaged they will ne...

Страница 18: ...ar maintenance of the product b Loss of time inconvenience loss of use of the product or other consequential or incidental damages c Parts that need replacement due to normal wear and tear d Superficial or cosmetic rust or corrosion e Any product whose name plate has been removed Products with warranty periods that differ from the standard 2 year warranty are as follows Poly Housings 25 years Fibe...

Страница 19: ...netzerotools com netzerotools com ...