Control

The WayCool® control switch is mounted on the outside of one frame leg.

It has the following positions:

OFF

power is off to the blower motor and the pump motor.

LOW VENT

the blower runs at low speed and the pump is OFF.

HIGH VENT

the blower runs at high speed and the pump is OFF. 

Use this setting to quickly dry the cooling pads for removal and cleaning.

LOW COOL

the blower runs at low speed and the pump is on. 

Use this setting for low cooling loads.

HIGH COOL

the blower runs at high speed and the pump is on. 

Use this setting for maximum cooling.

PUMP ONLY

pump is on and the blower is off. Use this 

setting during startup to first saturate the cooling pads, 
then switch to LOW COOL or HIGH COOL to begin cooling.

Control Switch

11

Operation and Maintenance

UNIT PLACEMENT AND OTHER CONSIDERATIONS

The WayCool® should be placed at one end of the
building and an appropriate exhaust fan should be at
the opposite end to pull the cool air from the WayCool®
and discharge the warm air out of the building.

Try to get all the air flowing in the same direction. Do
not direct other fans against the WayCool® as they will
counter the airflow and hinder the cooling effect.

Obstructing the airflow from the WayCool® severely
reduces the cooling effect.

Avoid using ceiling fans as they disrupt the airflow from
the WayCool®.

Use as many exhaust fans as possible to create a
natural draft through the building. This will enhance the
performance of the WayCool®.

Typical Arrangement

Содержание 1HP MFA Series

Страница 1: ...Portable Evaporative Cooler WayCool 1HP MFA Series USER S MANUAL WC 1HPMFA WC 1HPMFA360 WC 1HPMFAOSC WCG 1HPMFA...

Страница 2: ...Splattering in front 14 Leaking from the bottom 14 OPTIONS AND ACCESSORIES 15 Pneumatic wheels 15 Water conditioner and cleaner 15 Air filters 15 Aluminum grates 15 Oscillating spout 16 WARRANTY 17 Ta...

Страница 3: ...oling effect In an evaporative cooler the cellulose cooling pads take the place of your skin water instead of perspiration wets them and a fan moves the air The air blows across the cooling pads and e...

Страница 4: ...t Signal Words are used in conjunction with the safety alert symbol to identify the severity of the warning CAUTION indicates an imminently hazardous situation which if not avoided COULD cause damage...

Страница 5: ...careful and wear gloves when you reach under the frame to inspect the PVC pipes and mesh socks A GFCI Ground Fault Circuit Interrupter is recommended for use with this product If pads and grates are r...

Страница 6: ...ose the unit The blower is hung from the top of the frame and powered by a belt driven 1HP electric motor The blower draws room air through the cooling pads where it picks up moisture and cools by eva...

Страница 7: ...reservoir can also be filled manually with a hose or bucket if a hose connection is impractical Simply remove the cap and pour the water directly into the reservoir When you fill the reservoir manuall...

Страница 8: ...irt builds up water flow to the cooling pads is reduced and performance decreases The clear filter housing is threaded and screws into the filter body for easy removal to access the screen A dirty wat...

Страница 9: ...hen wet Always run the unit with the plastic retaining grates in place and handle them carefully when you clean them Crushed cells reduce the total airflow through the unit and therefore lowers its co...

Страница 10: ...which do not require lubrication A belt tensioner is connected to a bracket on the motor A rubber foot at one end rests against the blower bracket that is attached to the blower casing When the lockin...

Страница 11: ...st saturate the cooling pads then switch to LOW COOL or HIGH COOL to begin cooling Control Switch 11 Operation and Maintenance UNIT PLACEMENT AND OTHER CONSIDERATIONS The WayCool should be placed at o...

Страница 12: ...hand on the pad s inside your other hand on the outside and lifting the pad up and out from the bottom 6 Inspect the entire unit for shipping damage 7 Ensure the fan belt is attached to the motor and...

Страница 13: ...unit make sure there are no obstructions that could disrupt or block the airflow Make sure the unit is level at all times Keep the unit at least three feet away from walls or other obstructions that...

Страница 14: ...cover on the unit 5 Remove the top cover and set it aside 6 Locate the four PVC pipes in the top metal channel Each PVC pipe is secured to the Y connector by a single screw Remove this screw from all...

Страница 15: ...to be present in some water sources Place the tab under the float valve water outlet for fast effictive odor control Place the tab next to the pump for longer lasting odor control CLEANER WayCool cle...

Страница 16: ...e replaced IF SPOUT APPEARS TO JUMP WHILE OSCILLATING 1 The spout may be fastened too tight against the top of the WayCool The nut above the brace should be loosened to allow 1 16 clearance between th...

Страница 17: ...opriate or regular maintenance of the product b Loss of time inconvenience loss of use of the product or other consequential or incidental damages c Parts that need replacement due to normal wear and...

Страница 18: ...www schaeferfan com 2011 Schaefer Ventilation Equipment M WC1HPMFA 9 6 11...

Отзывы: