16.
LeakSmart Water Heater Kit
LeakSmart Water Heater Kit
Problem
What to Check
Leak Sensor becomes wet but LeakSmart Valve
- Locate plug connection between Control
does not close (continued)
Panel and LeakSmart Valve. Unplug the
connection and reconnect, making sure
arrows on the side of plugs line up.
- If an AC Power Adaptor Extension Wire was
used, unplug both ends and reconnect.
- Make sure fresh batteries are in the Control
Panel.
LeakSmart Valve closed but now will not open
- Make sure both sides of Leak Sensor are
dry.
The alarm goes off for no apparent reason
- Leak Sensor is touching metal, or the
concrete is sweating causing high humidity.
Correct the problem by placing the paper
sleeve on the Leak Sensor, or use a paper
towel as a barrier.
Troubleshooting
Manual Operation of LeakSmart Valve
1. Unplug the connection between the Control Panel and the LeakSmart Valve.
2. Pull the plastic motor cover off the LeakSmart Valve and slide it down the wire until it stops at the
plug. Note that no tools are needed to remove the cover.
3. Use a marker and draw a line across the top of the plastic motor housing. This way once the motor
is removed you will know how to reposition it for assembly.
4. Remove the 4 screws using a Phillips head screwdriver.
5. Place thumb and finger on plastic gear and rotate clockwise to open valve or counter clockwise to
close it. Do not use tools to manually open or close valve.
17.