background image

SmartSensor V

INSTALLER QUICK-REFERENCE GUIDE

2

  Select a mounting height

Determine the offset by 

measuring the distance 

from the nearest detection 

lane to the pole the sensor 

is mounted on.

Find the recommended 

mounting height by using 

this table.

The range of ideal offsets 

is highlighted in gray.

www.wavetronix.com  

801.734.7200

1

  Ensure that all necessary components are available

The components below, all of 

which can be ordered from 

Wavetronix, may be needed 

to install your SmartSensor 

V; for more information on 

any of these, see the 

Wavetro-

nix product catalog

.

Introduction

Complete steps 1–9 to integrate the Wavetronix SmartSensor V into your 

traffic application. If you need technical support or have questions, please 

contact Wavetronix Technical Services at (801) 734-7200. For more infor-

mation, see the 

SmartSensor V User Guide

.

Mount 

bracket

Sensor

Sensor 

cables

Preassembled 

cabinet

Home-

run cable

Offset from first 

Detection Lane 

(ft 

/ m

)

Recommended 

Mounting Height 

(ft 

/ m

)

Minimum  

Mounting Height 

(ft 

/ m

)

Maximum 

Mounting Height 

(ft 

/ m

)

9

 / 2.7

12

 / 3.7

9

 / 2.7

15

 / 4.6

15

 / 4.6

15

 / 4.6

12

 / 3.7

18

 / 5.5

20

 / 6

18

 / 5.5

15

 / 4.6

20

 / 6

25

 / 7.6

20

 / 6

17

 / 5.2

25

 / 7.6

30

 / 9.1

22

 / 6.7

19

 / 5.8

30

 / 9.1

35

 / 10.7

23

 / 7

20

 / 6

35

 / 10.7

40

 / 12.2

25

 / 7.6

22

 / 6.7

40

 / 12.2

45

 / 13.7

27

 / 8.2

23

 / 7

45

 / 13.7

50–80

 / 15–24

30

 / 9.1

25

 / 7.6

must be < offset

Отзывы: