4
Align the sensor to the roadway
1
Tilt the sensor down so that the front is aimed at the center of the detection area, as shown below.
2
Adjust the side-to-side angle
as close to perpendicular to
the flow of traffic as possible.
5
Attach the cable and pole-mount cabinet
To attach the cable to the sensor and the pole:
1
Squeeze about 25% of the silicon dielectric compound into the con-
nector at the base of the sensor. Wipe off any excess.
2
Insert the cable into the connector and twist clockwise until it clicks.
3
To reduce strain, strap the cable to the pole or run it through a con-
duit, leaving a small amount of slack at the top, as shown.
To attach the pole-mount cabinet to the pole:
1
Attach the mounting brackets to the back of the pole-mount box;
thread in the mounting straps.
2
Attach the pole-mount box to the pole using the mounting straps.
3
Run the sensor/homerun cables through the cable grips on the bot-
tom of the pole-mount box.
6
Connect surge protection and power
Standard Vs use the 8-conductor cable. To land this cable from the
sensor to the Click 200 in the pole-mount cabinet, do the following:
1
Disconnect the Click 200 from the DIN rail.
2
Disconnect the green screw terminals on the appropriate side of
the Click 200 and wire the sensor cable as shown at right.
3
Connect the Click 200 to the DIN rail.
4
Connect the ground terminal to the DIN rail and the earth
ground wire to the lug bolt on the bottom of the pole-mount box.
5
Connect the exterior lug bolt to earth ground.
6
Connect 10–30 VDC to the +DC and –DC terminals on the
appropriate side of the Click 200.
Note.
The Click 200 has sides marked PROTECTED and UNPRO-
TECTED; which you use depends on your installation. If you’re un-
sure, consult Chapter 2 of the
SmartSensor V User Guide
or Wavetro-
nix Technical Services.
This image shows wiring into the protected side, as
you would do if you had an underground cable run
connecting the pole-mount box to a traffic cabinet.
-DC (Black)
+DC (Red)
+485 (Stripe)
-485 (Blue)
CTS (Brown)
RTS (Orange)
Drain
TD (Yellow)
RD (Purple)