background image

© 2016 Wavetronix LLC. All rights reserved. Protected in the US by patents viewable at www.wavetronix.com/en/legal/patents. Protected by Canadian Patent Nos. 2461411; 

2434756; 2512689; and European Patent Nos. 1435036; 1438702; 1611458. Other US and international patents pending. Wavetronix, SmartSensor, Click, Command and all associated 

logos are trademarks of Wavetronix LLC. All other product or brand names as they appear are trademarks or registered trademarks of their respective holders. Product specifications 

are subject to change without notice. This material is provided for informational purposes only; Wavetronix assumes no liability related to its use.

WX-500-0317

Click 

Channels-Alerts-Zones

 on the main menu and then click the 

Setup 

Channels-Alerts-Zones

 button.

Enable a channel by clicking the 

Enabled

 checkbox.

Select 

Simple

 from the 

Type

 drop-down list. To see information about other 

channel types, see the 

SmartSensor Advance User Guide

.

Adjust the size of the zone by using the 

Range (feet):

 up/down arrows or by manu-

ally grabbing the zone’s blue arrows and dragging them anywhere on the roadway. 

If your installation has criteria for the range, speed and ETA, it should be changed 

here. If not, contact the engineer responsible for the intersection. Click the 

Speed

 

and 

ETA

 checkboxes to activate the Speed and ETA parameters.

Click 

OK

 to save the channel settings.

If you are not seeing detections appear at the desired distance, contact Wavetronix Technical Services.

9

  Set up a simple channel

Go to 

Tools >

 

Backup/Restore

 and specify where you want the backup file to be stored, then click 

Back-up Sensor Setup

To use a backup file, use the 

Restore Sensor Setup

 option on the same screen.

11

  Set up sensors on the Click 650

Before connecting the Click 650 to your network, you need to set the 

static IP address, subnet mask and default gateway (these numbers may 

be assigned by your IT personnel). You will set these using the OLED 

menu on the faceplate.

Navigate down to Network Setup and push the 

Accept

 (green check 

mark) button to open the networking screen (shown right).

Set your desired IP address by following these steps: use the left and right arrow keys to highlight a 

number, then use the up and down arrow keys to change that number. Then move to the next number. 

Repeat until all the numbers are changed.

Press the right key one last time to navigate down to the subnet mask line. Repeat steps 2 and 3 for the 

subnet mask and default gateway. When you’re done with all three, push the green check mark button to 

confirm your changes.

Connect an Ethernet cable to the RJ-45 jack on the faceplate of the device to connect your Click 650 to 

your network.

Connect to the web interface to configure the Click 650. Using the web interface, you’ll be able to map sen-

sor channels to detector channels and monitor sensor connections.

10

  Create a backup