![Wavetronix Click 111 Скачать руководство пользователя страница 8](http://html1.mh-extra.com/html/wavetronix/click-111/click-111_using-manual_3880473008.webp)
8 of 23
WX-501-0552 • 01.22
The switch patterns for the two parameters are identical, but bus 1 is configured using switches 1–4 (S1:1–4) while
bus 2 is configured using switches 5–8 (S1:5–8).
S1: Bus 1 Baud Rate
1
2
3
4
Value
Off
Off
Off
Off
Software mode
Off
Off
Off
On
9600 bps
Off
Off
On
Off
19200 bps
Off
Off
On
On
38400 bps
Off
On
Off
Off
57600 bps
All others
9600 bps
S2: Bus 2 Baud Rate
5
6
7
8
Value
Off
Off
Off
Off
Software mode
Off
Off
Off
On
9600 bps
Off
Off
On
Off
19200 bps
Off
Off
On
On
38400 bps
Off
On
Off
Off
57600 bps
All others
9600 bps
As these tables show, if the switches are in any configuration besides the ones laid out in the first few rows of
these tables, that bus will default to 9600 bps.
If any of the switches are on (flipped up), Hardware mode is selected, meaning the baud rate will be configured
using the DIP switches, and Click Supervisor and the front panel menu will be able to display the current setting,
but not change it. If all switches are off (down), Software mode is selected and only Click Supervisor and the front
panel menu will be able to both display and change the current setting.
Base Channel
This parameter selects how the Click 111 maps the incoming sensor outputs to the card’s outputs. The setting
determines the starting sensor channel that will be mapped to the associated bus’s output channel 1.
Example.
If you have this parameter set to 5 for bus 2, then sensor channel 5 will be mapped to output channel
1 on bus 2. And then the card will count up from there: if the bus has four channels allocated to it, then sensor
channel 6 will be mapped to output 2, sensor channel 7 will be mapped to output 3, and sensor channel 8 will be
mapped to output 4.
Note.
This parameter can also be changed using the front panel menu or Click Supervisor.
The switch patterns for the two parameters are identical, but bus 1 is configured using switches 1–4 (S2:1–4) while
bus 2 is configured using switches 5–8 (S2:5–8).