background image

22

23

TnT RCD

User Manual

Wavecom

TnT RCD

User Manual

Wavecom

Wavecom Tags & Accessories 

To support our test and print units we offer to you our range of electrical test tags that are made of the highest grade polypropylene 

and polyester label materials. These materials are robust and resistant to tearing and will cope with harsh Australian environments. 
It is recommended in extreme external conditions you use UV resistant tags

 

Wavecom Printable Tags

The test tags/labels we offer come in the full range of colours, each tag comes with a clear white area where a barcode can be 

printed into ensuring easy and accurate scanning, this results in the user being able to conduct fast scanning without issues.

All of the Wavecom tags are suitable for printing using every brand of thermal transfer printers available from around the world. The 

adhesive used on our tags is most aggressive and comes highly recommended for use in the electrical test and tag industry, there 
should be no butterflying once applied.

Order Information:

Lightweight ATT Tags (250 Tags) 

Suitable for most environments

Part no: WCM-ATT-TAGS-(B, BLK, BUR, GN, O, R, Y)

Medium Duty TT Tags (100 Tags) 

Suitable for indoor and outdoor 

use

Part no: WCM-TT-TAGS-(B, BLK, BUR, GN, O, R, Y, RAIN)

Heavy Duty TM Tags (100 Tags) 

Suitable for all but the most 

extreme environments

Part no: WCM-TM-TAGS-(B, BLK, BUR, GN, O, R, Y)

Super Heavy Duty TA Tags (100 Tags) Suitable for all industrial and 

outdoor sites

Part no: WCM-TA-TAGS-(B, BLK, BUR, GN, O, R, Y)

Optional Accessories

500mm Metal Braid for Earthing Appliances

Part No: TnT-ES 500 

3-Phase Adaptor 20A & 32A 5pin + 5pin

Part No: WCM-3PH-MADP 

HBC Fuse

Part No: WCM-HBC10AM205

Isolation Transformer for RCD testing

Part No: WCM-ISOT 

Probe Kit

Part No: WCM-Probe

WinPATS Extended Support (12 months)

Part No: WCM-WinPATS Support

IEC 20amp-10amp Current Limited Adapter Cable

Part No: WCM-IEC2010 

(Suitable for TnT RCD 20A Models Only)

Disclaimer – E&OE

All specifications may be subject to be change by Wavecom Pty. Ltd. without prior notice.

Updated Specifications & Model changes may be found on the Wavecom website: - www.wavecom.com.au

At the time of developing this manual, all care and consideration for accuracy has been implemented. Wavecom accepts no 

responsibility for any errors or omissions in this document. This is partly based on the fact that Electronics & Electrical testing and 

specifications worldwide are constantly changing and that Local, State and National Regulatory Authorities may also have differing or 

additional requirements. It is strongly recommended the Purchaser check Local Regulatory Standards that may be applicable in your 

region.

No part of this document may be Reproduced, Copied, Modified or Utilised in any way or form without the permission of Wavecom 

Instruments in writing.

Notes

Содержание TnT RCD

Страница 1: ...Wavecom User Manual Certificate of Warranty and Product Support Information TnT RCD Portable Appliance Tester ...

Страница 2: ... Tester should be calibrated every 12 months A correctly calibrated tester is essential for ensuring testing accuracy is maintained and for complying with the AS NZS 3760 2010 To book your tester in for calibration go to https www wavecom com au calibration_services php Then send your tester to your nearest calibration service centre For Western Australian customers Wavecom WA Calibrations Unit 2 ...

Страница 3: ...t 19 Leakage Test 20 Earth Continuity Test 20 Integrated Tests 20 No Connection No Test 21 Wavecom Tags 22 Tester Serial WinPATS Coupon Code Purchase Information Rear Cover TnT RCD Portable Appliance Tester IEC Test Lead 500mm Orange USB A to USB B Interface Cable Earth Lead with Alligator Clips 1800mm Black IEC Power Cable 10A units IEC 20 10 Power Cable with Circuit Breaker 20A Units 24 Month Co...

Страница 4: ...ents please contact your dangerous goods adviser and or review the IATA website www iata org publications dgr Pages index aspx This is not intended to constitute legal advice and you should obtain your own professional advice Please contact Wavecom Instruments Pty Ltd for more information Competent Person To ensure that all electrical equipment or devices are inspected tested and tagged correctly ...

Страница 5: ... red and A N is green there is a fault with the Mains Supply You may also see more than one or all of these turn red For more information see Mains Supply Test Page 25 Battery LEDs The battery LED indicators display how much charge is remaining in your TnT RCD Use the table below for reference 100 Battery is fully charged 80 60 40 20 LED 2 will be flashing 0 LED 1 will be flashing TnT RCD Testing ...

Страница 6: ...s a FAIL Tag with a DANGER tag and remove the device from service TnT RCD Testing Menu Main Menu B Use the Enter button to switch between Menu A and Menu B All tests on Menu B require a Mains Power source Power Test Menu B F1 The Power Test is for the purposes of monitoring and performance of equipment The Power Test feature is for single phase appliances only The Power Test allows the user to tur...

Страница 7: ... IEC socket of the TnT RCD then clamp it onto earthed metal on the appliance 5 If testing an RCD plug the IEC 550 Orange Cable into the IEC socket of the TnT RCD then plug it into a socket on your RCD and turn that switch on 6 Navigate to Main Menu B then press F2 to enter the Leakage Test Menu cont 7 Press a function key to start the test F1 Earth Leakage limit set to MAX then 5mA fail F2 Double ...

Страница 8: ...Inspection For details refer to the First Test section If the device passed the Visual Inspection continue with the following instructions if not refer to the First Test section 2 Navigate to Main Menu B and press F3 to enter the RCD Menu then press F1 to select Time Test 3 Press F3 to enter the Time Test options menu to ensure your TnT RCD has the correct settings for the type of RCD cont 4 cont ...

Страница 9: ...plied to the equipment times the current drawn by the equipment Both Watt and VA ratings have a use and purpose The Watt rating determines the actual power purchased from the utility company and the heat loading generated by the equipment Disclaimer Meter Mode is to be used for quick simple indicative electrical parameter measurements Providing reasonably accurate readings without the need to carr...

Страница 10: ...ween the exposed conductive material metal and the TnT RCD appliance tester This is done by means of connecting the earth lead with the crocodile clip probe attached to a GOOD earth point paint coatings will not provide effective connections and the appliance plugged into the TnT RCD appliance testers test socket The Maximum allowable limit is less than 1 0Ω Class 2 Double Insulated Construction D...

Страница 11: ...d this The Supply Mains Test checks the polarity and connectivity of the mains supply by LED s This test is also a part of all the testing functions of this unit If the central N E light is on red and you need to conduct load leakage tests DO NOT CONTINUE If you are carrying out standard Insulation and Earth Bond tests it is generally safe to continue This light will glow if a voltage difference l...

Страница 12: ...but the most extreme environments Part no WCM TM TAGS B BLK BUR GN O R Y Super Heavy Duty TA Tags 100 Tags Suitable for all industrial and outdoor sites Part no WCM TA TAGS B BLK BUR GN O R Y Optional Accessories 500mm Metal Braid for Earthing Appliances Part No TnT ES 500 3 Phase Adaptor 20A 32A 5pin 5pin Part No WCM 3PH MADP HBC Fuse Part No WCM HBC10AM205 Isolation Transformer for RCD testing P...

Страница 13: ...asino Street Welshpool WA 6106 P 08 9353 1943 F 08 9353 4319 E saleswa wavecom com au Wavecom VIC Mark Kennedy M 0430 299 164 P 03 9897 4711 F 08 8243 3501 E service wavecom com au Sold By Date of Purchase Purchase Information Tester Serial Number The TnT RCD is proudly designed and manufactured in Australia by Wavecom ...

Отзывы: