Wavecom Instruments Portable Appliance Testers Instruction Manual

 

 

 

16 

 

Optional Accessories 

 

WinPATS LogBOOK 

Part No: WCM-WinPATS LogBOOK 

WinPATS LogBOOK PRINT 

Part No: WCM-WinPATS Log PRINT (used with Wavecom Printer) 

Barcode Scanner

 

Part No: WCM-1200 Scanner USB (with LogBOOK only)

 

500mm Earth Strap

 

Part No: TnT-ES 500 

 

WAVECOM Tag Printer

 

Part No: WCM-Wavecom Printer (with LogBOOK only)

 

3-Phase Adaptor 20A

 

Part No: WCM-3Phase-20A

 

3-Phase Adaptor 32A

 

Part No: WCM-3Phase-32A

 

3-Phase Adaptor Multi (20A) (32A)

 

Part No: WCM-3Phase-M 

 

HBC Fuse

 

Part No: WCM-HBC10AM205

 

Test Probe Kit 

Part No: WCM-Probe-Kit 

Rugged Case (L)  

Part No: WCM-HTC-L 

Tag Remover 

Part No: WCM-Kutter 

Laminated Tags 

Part No: WCM-TT-Generic-Tags 

SPECIFICATIONS TNT ®G4- Series 

 

Mains Supply Test 

 

Checks Polarity and continuity of mains supply by LED indicators 

(A-N, A-E, and N-E). (Flashing-        Test Fail indicator) 

 
 
 
 
 

CLASS 1 Earthed Appliance 

 

Appliance Check: Ensures appliance is plugged in and  turned on.

 

Earth Bond Test: 200mA test current. Pass level Less than 1.0 Ω. Measurement: 0.01Ω to 10 Ω.

 

Insulation Test: 500VDC / 250VDC. Pass level Greater than 1M Ω. 

Measurement: 0.1Ω to 10MΩ. 

*See also Leakage Test

 

 

CLASS 2 Double Insulated Appliance

 

Appliance Check: Ensures appliance is plugged in and  turned on.

 

Earth Bond Test: 200mA test current. Pass level Less than 1.0Ω. Measurement: 0.1Ω to 10Ω. 

Insulation  Test:  500VDC  /  250VDC.  Pass  level  greater  than  1MΩ.  Measurement:  0.1Ω  to  10MΩ. 
 

*See also Leakage Test

 

 

Extension Leads 

Earth Bond Test: 200mA test current. Pass level Less than 1Ω. Measurement: 0.01Ω to 10.0Ωs

 

Insulation Test: 500VDC / 250VDC . Pass level Greater than 1MΩ. Measurement: 0.1Ω to 10.0MΩ. 

Continuity Test: 250VAC check continuity and polarity of leads. Displays Pass/Fail. 

Polarity Test: 250VAC check continuity and polarity of leads. Displays Pass/Fail.

 

  

Leakage Test * 

Leakage Current: 0 to 30.0mA at 200 to 265V

 

Earth Leakage Test: 240VAC Mains. Pass level 1, 2.5, 5.0 mA leakage test levels with up to 10Amp load operation.

 

Note 1: 

Pass level for CLASS 1 is 5 mA  

Pass level for CLASS 2 is 1 mA 

Содержание TnT ELB G4-Series

Страница 1: ...ad Findon SA 5023 Phone 61 08 8243 3500 Fax 61 08 8243 3501 Email sales wavecom com au Web www wavecom com au Melbourne Office 772A Station Street Box Hill Victoria 3128 Phone 1300 793 301 Fax 61 03 9...

Страница 2: ...Wavecom Instruments Portable Appliance Testers Instruction Manual 2...

Страница 3: ...ure personal safety The Manufacturer also advises that appliance testing should be conducted by a Competent and suitably trained person as referred to under the current Standard AS3760 2010 as well as...

Страница 4: ...tery power bank DO NOT send this item by any shipping company This includes the power bank by itself or with equipment Please remove the battery power bank first If you have any transportation queries...

Страница 5: ...ipment The knowledge of how to use the relevant testing instruments interpret and record the results for compliance with the Standard Workplace requirements The knowledge to be able to correctly recom...

Страница 6: ...method of construction employs two safety barriers comprising two layers of insulation between dangerous voltages and the user of the equipment The first layer of insulation is formed around the live...

Страница 7: ...ps MAXIMUM Resistive Load only Standard TNT Series units A Leakage Test applies power to the Device under Test DUT and measures the imbalance of leakage current from the DUT between the active and neu...

Страница 8: ...est function ensures that the appliance is plugged into the TnT appliance tester and that it is switched on If the device is not plugged in and the TnT appliance tester detects that no device is prese...

Страница 9: ...components if fitted are checked All labels markings and warning indicators of the maximum load to be connected to the device are legible and intact The insulation is not damaged in any way i e melted...

Страница 10: ...rvice Refer to the Technical Information section to change test voltage Procedure 1 Complete a Visual Inspection Only proceed if test passed 2 Plug device into appliance socket 3 Connect earth clip to...

Страница 11: ...Test Ext Lead Test F3 Please Note A Visual Inspection test must be carried out before any others refer to First Test Section The Lead TEST completes the following sequence as part of its comprehensive...

Страница 12: ...est to be carried out instead The TNT Series appliance testers have been designed to perform these tests The Leakage Test applies power to the Device Under Test and measures any imbalance or leakage c...

Страница 13: ...ncrements The value can be changed by selecting the leakage test time in the options menu See the special functions section of the manual for more details The factory default setting is 20sec The valu...

Страница 14: ...t any time The unit will power down after 20 seconds as factory default Caution This test turns the Equipment ON The power leakage test can handle up to 10 Amp Resistive Load MAX Exceeding this value...

Страница 15: ...screen displays 1 option at a time You can select this option by pressing the return button To select the next item press the F2 button Pressing the F3 button escapes out of the TnT options menu Chang...

Страница 16: ...Ensures appliance is plugged in and turned on Earth Bond Test 200mA test current Pass level Less than 1 0 Measurement 0 01 to 10 Insulation Test 500VDC 250VDC Pass level Greater than 1M Measurement 0...

Страница 17: ...h green and device will power up Otherwise press enter to exit Warning Screen Amps Screen Watts Screen Volts Amps Screen Press the enter key to stop the power mode and return to volts Pressing F3 key...

Страница 18: ...uting systems may draw from a power grid the VA is used to determine the kind of wiring and circuit breakers required to support the computing equipment in question Watts and VA Detailed Explanation T...

Страница 19: ...he USB B port in the rear of the unit with USB A port on power bank using the supplied cable Press the Enter button for 2 seconds until the unit starts up To shut down the unit keep pressing the same...

Страница 20: ...cations worldwide are constantly changing and that Local State and National Regulatory Authorities may also have differing or additional requirements It is strongly recommended the Purchaser check Loc...

Страница 21: ...rder information TA TAGS Part no WCM TA TAG BL GN Y O BLK Colour BL Blue GN Green Y Yellow O Orange BLK Black ATT TAGS Roll of 250 These laminated generic tags come in various colours and in rolls of...

Страница 22: ...th all regulations noting that extensive penalties can be imposed by the relevant authorities for any breach The IATA and other laws and regulations covering the transport of goods are very comprehens...

Страница 23: ...Wavecom Instruments Portable Appliance Testers Instruction Manual 23...

Страница 24: ...liance Testers Instruction Manual 24 Portable Appliance Testers TnT G4 Series www wavecom com au V010613 Note TnT Firmware TnT G4 series in general have the ability to be updated to comply with potent...

Отзывы: