Introduction

 

This meter measures AC/DC Voltage, AC/DC Current, Resistance, Capacitance, 
Frequency (electrical & electronic), Diode Test, and Continuity plus Thermocouple 
Temperature. It features a waterproof, rugged design for heavy duty use. Proper use and 
care of this meter will provide many years of reliable service. 
 

What’s included in Kit

 

Wavecom 89 True RMS Multimeter 

 

One pair of test probes and accessories 

 

Temperature probe 

 

This Instruction Booklet 

 

Protective case 

Safety

 

This symbol adjacent to another symbol, terminal or operating 
device indicates that the operator must refer to an explanation in the 
Operating Instructions to avoid personal injury or damage to the 
meter. 

This 

WARNING

 symbol indicates a potentially hazardous situation, 

which if not avoided, could result in death or serious injury. 

This 

CAUTION

 symbol indicates a potentially hazardous situation, 

which if not avoided, may result damage to the product. 

This symbol advises the user that the terminal(s) so marked must 
not be connected to a circuit point at which the voltage with respect 
to earth ground exceeds (in this case) 1000 VAC or VDC. 

This symbol adjacent to one or more terminals identifies them as 
being associated with ranges that may, in normal use, be subjected 
to particularly hazardous voltages. For maximum safety, the meter 
and its test leads should not be handled when these terminals are 
energized. 

This symbol indicates that a device is protected throughout by 
double insulation or reinforced insulation. 

 

 
PER IEC1010 OVERVOLTAGE INSTALLATION CATEGORY 

OVERVOLTAGE CATEGORY I 

Equipment  of  OVERVOLTAGE  CATEGORY  I  is  equipment  for  connection  to  circuits  in  which 
measurements are taken to limit the transient overvoltages to an appropriate low level. 
Note 

– Examples include protected electronic circuits. 

OVERVOLTAGE CATEGORY II 

Equipment  of  OVERVOLTAGE  CATEGORY  II  is  energy-consuming  equipment  to  be  supplied  from 
the fixed installation. 
Note 

– Examples include household, office, and laboratory appliances. 

OVERVOLTAGE CATEGORY III 

Equipment of OVERVOLTAGE CATEGORY III is equipment in fixed installations. 
Note 

– Examples include switches in the fixed installation and some equipment for industrial use with 

permanent connection to the fixed installation. 

OVERVOLTAGE CATEGORY IV 

Equipment of OVERVOLTAGE CATEGORY IV is for use at the origin of the installation. 
Note 

– Examples include electricity meters and primary over-current protection equipment

 

 

WARNING 

CAUTION 

MAX 
1000V

 

Содержание 89

Страница 1: ...A VAC VDC MAX MIN TEMP CAP TEMP True RMS Industrial Multimeter MODEL WAVECOM 89 Wavecom Instruments Pty Ltd 257 Grange Road FINDON SA 5023 P 61 08 8243 3500 F 61 08 8243 3501 sales wavecom com au www...

Страница 2: ...acent to one or more terminals identifies them as being associated with ranges that may in normal use be subjected to particularly hazardous voltages For maximum safety the meter and its test leads sh...

Страница 3: ...EXTREME CAUTION when working with high voltages 3 DO NOT measure voltage if the voltage on the COM input jack exceeds 600V above earth ground 4 NEVER connect the meter leads across a voltage source w...

Страница 4: ...e on rear of unit Note Input Jacks for test probes are a firm fit to prevent dislocation Take care to fully insert banana plug into jack Symbols and Annunciators Auto power off Continuity Diode test B...

Страница 5: ...Risk of Electrocution The probe tips may not be long enough to contact the live parts inside some 240V outlets for appliances because the contacts are recessed deep in the outlets As a result the read...

Страница 6: ...FREQUENCY DUTY CYCLE MEASUREMENTS CAUTION Do not make 20A current measurements for longer than 30 seconds Exceeding 30 seconds may cause damage to the meter and or the test leads 1 Insert the black te...

Страница 7: ...continuity on circuits or wires that have voltage on them 1 Set the function switch to the CAP position 2 Insert the black lead banana plug into the negative COM jack Insert the red test lead banana...

Страница 8: ...ve the batteries and unplug the line cords 1 Set the rotary function switch to the CAP position 2 Insert the black test lead banana plug into the negative COM jack Insert the red test lead banana plug...

Страница 9: ...the minimum reading and will update only when a new min occurs 3 To exit MAX MIN mode press and hold the MAX MIN key for 2 seconds RELATIVE MODE The relative measurement feature allows you to make mea...

Страница 10: ...chemicals cleaning solvents or detergents 5 USE ONLY FRESH BATTERIES OF THE RECOMMENDED SIZE AND TYPE Remove old or weak batteries so they do not leak and damage the unit 6 IF THE METER IS TO BE STOR...

Страница 11: ...the battery 4 Remove the six A screws securing the rear cover 5 Gently remove the old fuse and install the new fuse into the holder 6 Always use a fuse of the proper size and value 0 8A 1000V fast blo...

Страница 12: ...ranges are specified from 5 of range to 100 of range DC Current 600 A 0 1 A 1 0 reading 3 digits 6000 A 1 A 60mA 0 01mA 600mA 0 1mA 6A 0 001A 1 5 reading 3 digits 10A 0 01A 20A 30 sec max with reduced...

Страница 13: ...999MHz 0 001MHz 40MHz 01MHz Sensitivity 0 8V rms min 20 to 80 duty cycle and 100kHz 5Vrms min 20 to 80 duty cycle and 100kHz Frequency electrical 10 00 400Hz 0 01Hz 0 5 reading Sensitivity 15Vrms Dut...

Страница 14: ...is displayed Auto Power Off 15 minutes approximately with disable feature Polarity Automatic no indication for positive Minus sign for negative Measurement Rate 2 times per second nominal Low Battery...

Страница 15: ...15...

Страница 16: ...Road FINDON SA 5023 Ph 61 08 8243 3500 Fax 61 08 8243 3501 Email sales wavecom com au Web www wavecom com au Melbourne 772A Station Street BOX HILL VIC 3128 Ph 61 03 9897 4711 Fax 61 03 9897 4766 Ema...

Отзывы: