background image

Occupancy 
sensor lens

LED blinks 
when 
occupancy is 
detected

THE DI-110 PERSONAL SENSOR

The DI-110 personal sensor uses passive 
infrared technology to detect occupancy 
within a workspace. 

When the sensor detects occupancy, 
it automatically turns on the power 
strip’s six controlled outlets. It turns off 
these outlets when it no longer senses 
occupancy in the workspace and the 
user-set 

time delay

 elapses. (See “Time 

Delay Setting.”) 

Uncontrolled outlets are continuously powered by the power strip and 
remain on regardless of occupancy.

Time Delay Setting 

The personal sensor automatically turns off all controlled devices after 
a workspace becomes vacant and a pre-set time interval, or time delay, 
elapses. This setting is user-adjustable. 

Turning the trimpot dial, located on the back on the sensor, clockwise 
or counterclockwise adjusts the time delay. The range for adjustment is 
30 seconds to 30 minutes. 

•  To adjust to 30 seconds (minimum), turn the dial 

completely counterclockwise.

•  To adjust to 30 minutes (maximum), turn the dial 

completely clockwise.

•  To adjust to 15 minutes, turn the dial half way 

between its maximal clockwise and counterclockwise positions.

Note: Use a small screwdriver to make adjustments.

Initial Warm-up 

The personal sensor requires an initial warm-up period of up to two 
minutes whenever the power strip is initially turned on. During this 
time, all connected devices will remain on, regardless of occupancy or 
the time delay setting.

Putting a stop to energy waste.

Min

Max

Содержание IDP-3050-A

Страница 1: ...vides surge protection Its use reduces energy costs and helps the environment by turning power consuming devices off based on occupancy THE POWER STRIP The power strip provides surge protection It also filters noise caused by electromagnetic interference EMI and radio frequency interference RFI Outlets Six of the power strip s eight outlets are controlled by the personal sensor and the remaining tw...

Страница 2: ...indicator labeled Grounded is lit when the wall outlet is properly wired and grounded The surge protection will not operate if the power strip is not properly grounded ON OFF switch Sensor controlled outlets Uncontrolled outlets Diagnostic Lights Both are lit to indicate normal operation Use Sensor Controlled outlets for appliances and items that don t need to be powered while you are away from yo...

Страница 3: ...mes vacant and a pre set time interval or time delay elapses This setting is user adjustable Turning the trimpot dial located on the back on the sensor clockwise or counterclockwise adjusts the time delay The range for adjustment is 30 seconds to 30 minutes To adjust to 30 seconds minimum turn the dial completely counterclockwise To adjust to 30 minutes maximum turn the dial completely clockwise T...

Страница 4: ...ts to be free of defects in materials and workmanship for a period of five 5 years There are no obligations or liabilities on the part of Watt Stopper Legrand for consequential damages arising out of or in connection with the use or performance of this product or other indirect damages with respect to loss of property revenue or profit or cost of removal installation or reinstallation If the Protect...

Отзывы: