5 Installation
To find the ideal mounting height of the charger.
4 NEMA Plug-in Outlet
This section introduces how to install a NEMA outlet if you do not have
one already.
Switch off the circuit breaker of the electrical outlet before installing
your charger.
When installing a NEMA 14-50 outlet, ensure that the ground pin is
facing up as shown per the diagram.
Ensure you have the correct permits for this electrical installation.
The power supply cable length is limited to 11.8” (30 cm).
WARNING
IMPORTANT
NEMA 14-50P
NEMA 6-50P
240V
To reduce the risk of fire, connect only to a circuit with a branch
circuit over-current protection of 50 A in accordance with ANSI/
NFPA 70 (US) C22.2 NO.280-13 (Canada).
CAUTION
Risk of shock. Turn off the power to the outlet at the circuit breaker
until the installation is completed.
DANGER
120V
120V
240V
120V
120V
X
y
X
y