Page 12

 

 

 
 
 
 

 

 

 

 

 
 
 

 
 

 

Connect the Blue Tube from the Faucet to RO Module

Step 26

Step 25

Connect the Red Tube from Airgap Faucet to RO Module

The drain line fl ow control is factory installed inside of the stem elbow on the inside of the 
bracket.

Insert the blue 3/8” tube from the faucet into the port on the system 
marked “FAUCET”.  Make sure the tube is pushed in all the way 
to the tube stop.

Start up Instructions

If system is connected to an ice maker, turn the ice maker off (or do not allow water to fl ow to 
the ice maker) until Step 5 “fl ushing” is complete and the tank has been allowed to completely 
fi ll. Connection from the RO to the ice maker system should have an in-line valve installed 
before the ice maker so it can easily be closed to prevent water fl owing to the ice maker 
during start up and periodic maintenance. Your RO tank must be allowed to fi ll up in order 
for the ice maker system to work properly. (If you are installing an ice maker kit from Watts, 
tee off of the blue line between RO system and faucet).

 After the Tank has fi lled, open the faucet to fl ush the tank completely to remove carbon particles 
from fi nal fi lter.  Repeat this step two more times.  The fourth tank can be used for drinking. 

 

*Note:  The fl ushing of the tank 3 times is only necessary during initial installation. 
This should take about a day to complete.

Open the RO faucet and leave it open until water begins to trickle out, (it will come out 
slowly).

Step 5

Turn on the incoming cold water at the angle stop valve.  Open the needle valve on the brass 
Adapta Valve by turning counter clockwise. Check the system for leaks and tighten any fi tting 
as necessary.  (Check frequently over the next 24 hours to ensure no leaks are present).

Step 4

Step 3

Step 2

Step 1

After water trickles out of the faucet, close the faucet so the tank will fi ll with water.  The tank 
will take 3 to 6 hours to fi ll completely depending on the production capability of the membrane, 
local water temperature and pressure.

Step 27

Identify each cartridge and the proper location on the system by 
matching the colors and description.

Install the Cartridges

Step 28

Insert each cartridge with a 1/4 turn in the clock wise direction.  The cartridge 
is installed properly when the label is facing toward the front of the unit.

         Flow Restrictor inside Drain fi tting 

                       Tank Connection 

Red tube will connect to drain saddle for Non Airgap Faucet. 

Note:

Содержание WQT4RO11-50

Страница 1: ...ase read carefully before proceeding with installation Your failure to follow the instructions or operating parameters may lead to the product s failure and possible damage to property Please save thi...

Страница 2: ...Carbon filter recommended change 6 months The second stage contains a carbon block filter This helps ensure that chlorine and other materials that cause bad taste and odor are greatly reduced Stage 3...

Страница 3: ...or the Faucet in a Stainless Steel Sink 5 Faucet Installation 6 Adapta Valve Installation 7 Reverse Osmosis Module Mounting 7 Air Gap Non Air Gap Installation 8 Drain Saddle Installation 9 Tank Valve...

Страница 4: ...copper tubing is down stream of the RO Be sure to follow any state or local regulations Operational Parameters Note The operating pressure in your home should be tested over a 24 hour period to attai...

Страница 5: ...l or liquid soap to keep the hole saw cool during cutting Step 2 Drill a Hole for the Faucet in a Porcelain Sink Punch a Hole for the Faucet in a Stainless Steel Sink Drill a pilot hole Use a 1 2 Hole...

Страница 6: ...llips head screwdriver turn the screw clockwise until the toggle bolt secures the faucet base snug onto the sink top do not over torque toggle bolt 5lb in max Once the faucet base is securely fastened...

Страница 7: ...en doing maintenance on unit Step 10 Step 12 Attach adapta valve as illustrated in the three photos above choosing the configuration that fits your plumbing When attaching the adapta valve to straight...

Страница 8: ...Page 8 Non Air Gap Faucet Installation Air Gap Faucet Installation...

Страница 9: ...ircle cut out of the middle must be applied to the inside of the drain saddle Remove sticky tape backing and stick to the drain saddle as shown 2 Screws 1 Semi bracket with opening 2 Nuts for screws 1...

Страница 10: ...e parts bag Place nut on the tube first then the sleeve Small taper end of sleeve must point to the end of tube and then insert the brass insert into the end of the tube Insert the black tube into the...

Страница 11: ...Use the Quick Connect Fittings on the RO Module To make a connection the tube is simply pushed into the fitting It is essential that the outside diameter be free of score marks and that burrs and sha...

Страница 12: ...ve carbon particles from final filter Repeat this step two more times The fourth tank can be used for drinking Note The flushing of the tank 3 times is only necessary during initial installation This...

Страница 13: ...component should be with one of identical specifications as defined by the manufacturer to assure the same efficiency and contaminant reduction performance Periodic inspection and following proper sy...

Страница 14: ...ply at the adapta valve Step 7 Allow the RO unit to fill the tank overnight Step 8 Open the faucet and allow the tank to empty and then close the faucet Step 9 Replace the post carbon filter cartridge...

Страница 15: ...on Use If the system will not be used for an extended period more than 2 months perform the following Turn on the water supply at the adapta valve Step 1 Step 2 Step 3 Step 4 Step 5 Turn off the incom...

Страница 16: ...e Page 15 4 Noise from faucet or drain Air gap faucet Inherent sound with air gap faucets Location of drain saddle See diagram for proper location of drain saddle Higher capacity membrane Normal with...

Страница 17: ...Purchase __________ Date of Install ___________ Installed by __________________ Serial No _____________________ Date 1st stage Sediment 6 months 2nd stage Carbon 6 months 4th stage Carbon 1 year 3rd...

Страница 18: ...2 The hardness of the water should not exceed 10 grains per gallon or 170 ppm 3 Maximum incoming iron must be less than 0 2 ppm 4 The pH of the water must not be lower than 2 or higher than 11 5 The i...

Страница 19: ...TORAGE TANK WHITE PLASTIC 7 1 PPSV501222W VAVLE BALL 3 8 x 1 4 FEMALE ELBOW 8 1 WTMFAG C FCT TOP MOUNT CHROME AIRGAP FAUCET 9 1 FU WDF 103 3NSF FCT LONG REACH CHROME NON AIR GAP 10 1 FU AGLR C 3 FCT L...

Отзывы: