Page 13
The following steps should be followed to change the cartridges.
Cartridge Replacement
Cartridge replacement is made easy with the Watts Kwik Change system. The cartridge heads contain
built in check valves and shutoff valves so that the cartridges can be changed without shutting off the
water supply or the storage tank. The head are also hinged to allow easy access to the cartridges.
Note: A small amount of water may be released when changing cartridges.
NOTE:
This reverse osmosis system contains replaceable components critical to the effi ciency of
the system. Replacement of the reverse osmosis component should be with one of identical
specifi cations, as defi ned by the manufacturer, to assure the same effi ciency and contaminant
reduction performance. Periodic inspection and following proper system maintenance is critical
for continued performance.
Step 1 Rotate the cartridge 1/4 turn counter clockwise.
Step 2 Remove the cartridge and dispose of it.
Step 3 Remove the protective cap from the new cartridge.
Step 4 Orient the cartridge with the label facing to the left ( 9 o’clock postion).
Step 5 Push the cartridge into the head and rotate it clock wise 1/4 turn.
Step 6 Wipe up any spill water.
The Sediment cartridge, and Pre carbon cartridge should be changed every six
months.
The RO membrane cartridge should be changed every one or two years.
The Post carbon cartridge should be changed once a year.