7
EN
7. Compatible thermostats
Digital Wireless Heat & Cool
Analogic Wireless Heat & Cool
Programmable Wireless Heat & Cool
8. Technical characteristics
9. Dimensions
49 mm
49 mm
83 mm
Environment:
Operating temperature
Shipping and storage temperature
Thermal safety temperature (relay opening)
0°C to 40°C
-10°C to +50°C
When > 85°C (back to standard mode when < 65°C)
Power supply
230VAC 50Hz with European plug socket
Electrical protection
Cat. II - IP20
Output
Maximum Résistive Load Relay
Relay 10 A Max
230V 50Hz
Radio Frequency & RF
Receiving distance
868,3 MHz < 10mW (Bidirectional communication)
30m in residential environment (100m in open field)
EU declaration of conformity
Hereby, Watts Electronics declares that the
equipment is in compliance with the relevant
Community harmonization legislation
Low voltage (LVD) - Directive 2014/35/EU
Electromagnetic compatibility (EMC) - Directive 2014/30/EU
Radio equipment - Directive 2014/53/EU
Restriction of the use of certain hazardous substances (RoHS)
- Directive 2011/65/EU
The full text of the EU declaration of conformity is available on
wattswater.eu
Product is in compliance with
Classification
Contribution
UE 811/2013 and 2010/30/UE
IV
2%