3
2. Display description
3. Technical characteristics
A
(push button)
B
(red/green)
C
(red/blue)
D
(orange)
/
/
/
/
OFF mode
Short press
/
/
/
ON/OFF trigger with bip
/
Green fix
/
/
Comfort mode
with the 2 ouputs opened
(without heating, without cooling)
/
Green 50%
/
/
Reduced mode
with the 2 ouputs opened
(without heating, without cooling)
/
Green 10%
/
/
Antifreeze mode
with the 2 ouputs opened
(without heating, without cooling)
/
/
Red
/
Heating demand
(Heating output closed)
/
/
Blue
/
Cooling demand
(Cooling output closed)
10sec press
/
/
Orange slow flash
RF pairing with a thermostat
or the central unit
/
/
/
Orange quick flash
RF reception
/
/
/
Orange quick flash permanently
RF signal lost
/
Red / green flash
/
/
Error on Thermostat sensor
30sec press
Orange
Blue/red
Orange
Reset of the receiver
Environment. (Temperatures)
Operating /shipping et storage
0°C - +40°C
-10°C to +50°C
Power supply
230Vac 50Hz
Electrical protection
Class II - IP33
Output
Maximum Load
2 x Relay 5A 250VAC
Up to 5A resistive - 250Vac 50Hz (2 wires L,N)
Radio Frequency &
RF Receiving distance
868MHz < 10mW (Bidirectional communication)
Range of approximately 100m in open space
Range of approximately 30m in residential environment
CE Directives
Your product has been designed in conformity
with the European Directives.
EN 60730-1:2017 / EN 60730-2-9:2021 / EN IEC 61000-3-2:2019 + AMD1:2021
EN IEC 61000-3-3:2013 + AMD1:2017 + AMD2:2021 / EN 55014-1:2017
EN 55014-2:2015 / EN 55024:2010 + A1:2015 / ETSI EN 301 489-3 V2.1.1
ETSI EN 301 489-1 V2.2.3 / ETSI EN 300 220-1 V3.1.1 / ETSI EN 300 220-2 V3.2.1
EN IEC 63000:2018 / Regulation (EU) 2015/1188 / Regulation (EU) 2013/813
Classification / Contribution
IV / (2%)
Regulation characteristics
Proportional Integral regulation or Hysteresis regulation. Regulation is defined by
thermostat linked to each channel (see thermostat leaflet)
EN
A
D
B
C