8. 

Critical Settings (Continued)

Display

Range

Access

Description

°F or °C
Default = 
°F 

Installer
User

TEMPERATURE UNITS

Press the 

 or the 

 button to 

change from °F to °C and vice versa.

 Set To:

H1

H1

ADJUST

ADJUST

SUPPLY

OFF or 
On
Default = 
On

Installer

HEAT SUPPLY PUMP

During heating, select whether or not 
the system supply pump should turn 
on or be off to allow a zone group 
pump per manifold.
Available when:

•  A reset control is present on the 

tekmarNet

®

 system.

Set To:

H1

H1

ADJUST

ADJUST

SUPPLY

OFF or 
On
Default = 
OFF

Installer

HEAT SUPPLY PUMP DELAY

During heating, select whether or not 
the system supply pump should be 
delayed by 3 minutes before coming 
on (for thermal motor or wax actuator).
Available when:

•  A reset control is present on the 

tekmarNet

®

 system.

Set To:

On or Off
Default = 
On

Installer

ROOM SENSOR

Select whether the built-in air 

temperature sensor is on or off. 
Available when:
A floor sensor or room sensor is 

installed on the auxiliary sensor 

input.

Set To:

Off, 
Room, 
Outdoor, 
Floor, 
Floor dSP

Installer

AUXILIARY SENSOR

Select the type of auxiliary sensor.
Floor dSP = Show floor sensor reading 

in upper number field. 
Available when:
Auxiliary sensor automatically 

detected.

Set To:

Содержание tekmar tekmarNet 2

Страница 1: ...Location 2 Remove Mounting Base 3 Install Mounting Base Thermostat Base Adaptor Plate 007 Switch Box OR Thermostat Base Wall Exterior Wall Behind Door Interior Wall 5 feet 1 5 m tekmarNet 2 Thermostat...

Страница 2: ...rochure Use at least 65 C conductors ON Sensor 3 4 Setback Scene Lock Not used Not used Unlock O O No Power Switch Setting Location Switch Position Action 1 ON SETBACK Allow thermostat to respond to a...

Страница 3: ...level to Installer Return to Lock setting once installation has been completed Press and hold down both the and buttons for 2 seconds to change from one step to the next Release both buttons once the...

Страница 4: ...fault On Installer HEAT SUPPLY PUMP During heating select whether or not the system supply pump should turn on or be off to allow a zone group pump per manifold Available when A reset control is prese...

Страница 5: ...irez la base de montage 3 Installez la base de montage Mur ext rieur Mur int rieur 5 pi 1 5 m Commutateur bo te OU Base de thermostat Mur Base de thermostat Plaque adaptrice 007 tekmarNet 2 Thermostat...

Страница 6: ...re au thermostat de r pondre au calendrier disponible N cessite Minuterie 033 OFF OFF aucune r ponse de calendrier de marge de recul 2 ON SC NE permettre au thermostat de r pondre des sc nes N cessite...

Страница 7: ...veau d acc s installateur Retour pour Verrouiller r glage une fois l installation termin e Appuyez et maintenez les deux boutons et pendant 2 secondes pour passer d une tape l autre Rel chez les deux...

Страница 8: ...ar d faut OFF Installateur RETARD DE LA POMPE D ALIMENTATION EN CHALEUR Au cours du chauffage s lectionner si oui ou non la pompe d alimentation du syst me doit tre retard e de 3 minutes avant de d ma...

Страница 9: ...je 3 Instalaci n de la base de montaje Base del termostato Placa adaptadora 007 Caja de interruptor O Base del termostato Pared Pared exterior Pared interior 5 pies 1 5 m tekmarNet 2 Thermostat 528 Gu...

Страница 10: ...ESBLOQUEAR desbloquee para acceder a todos los ajustes Desbloquee el acceso durante la instalaci n 4 ON No se utiliza OFF No se utiliza 1 2 3 4 tN2 Manager Module or Wiring Center tN2 tN2 Slab Sensor...

Страница 11: ...cambiar el nivel de acceso a instalador C mbielo nuevamente a Bloquear opci n Lock luego de finalizar la instalaci n Mantenga apretados los botones y por 2 segundos para cambiar de una opci n a la si...

Страница 12: ...acci n seleccione si quiere que la bomba de suministro del sistema se prenda o no y que de esta forma haya una bomba de grupo por zona en cada colector Disponible si El sistema tekmarNet tiene un cont...

Отзывы: