background image

© 2019 tekmar  564_Q - 10/19

3 of 16

•  Improper installation and operation of this thermostat could result in damage to the 

equipment and possibly even personal injury or death.

•  This thermostat is not intended for use as a primary limit control. Other controls that 

are intended and certified as safety limits must be placed into the control circuit.

Thermostat Location

Consider the following:

•  Interior wall. Keep dry. Avoid potential 

leakage onto the control.

•  No draft, direct sun, or other cause 

for inaccurate temperature readings. 

•  Away from equipment, appliances, 

or other sources of electrical 
interference.

•  Approximately 5 feet (1.5 m) off the 

finished floor.

•  The maximum length of wire is 500 

feet (150 m).

Installation

Please be aware local codes may require this thermostat to be installed or connected by 
an electrician.

Ensure power to connecting equipment is off. To prevent the risk of 
personal injury and/or death, make sure power is not applied to the ther-
mostat or HVAC Interface Module until they are fully installed and ready 
for configuration. All work must be done with power to the circuit being 
worked on turned off.

1. Remove the old thermostat

If more than 2 wires are present, identify the Red & Common wires for use when connecting 
the Invita WiFi Thermostat. Additional wires should be secured in a way that prevents them 
from touching the circuit board or terminals on the Invita after the R & C wires are connected.

Содержание Tekmar Invita 564

Страница 1: ...umidifier dehumidifier HRV ERV ventilator Need more information Refer to the User Brochure for information on using the thermostat and app Refer to the Voice Control Manual for details on voice control features Refer to the Operation Manual for in depth installation and operation details Scan to open Invita webpage All literature is available from tekmarControls com Invita Invita WiFi Thermostat 5...

Страница 2: ... failure to act which could result in property damage or damage to the equipment This is a safety alert symbol The safety alert symbol is shown alone or used with a signal word DANGER WARNING or CAUTION a pictorial and or a safety message to identify hazards When you see this symbol alone or with a signal word on your equipment or in this Manual be alert to the potential for death or serious perso...

Страница 3: ...ately 5 feet 1 5 m off the finished floor The maximum length of wire is 500 feet 150 m Installation Please be aware local codes may require this thermostat to be installed or connected by an electrician Ensure power to connecting equipment is off To prevent the risk of personal injury and or death make sure power is not applied to the ther mostat or HVAC Interface Module until they are fully insta...

Страница 4: ...rmostat Align the 2 notches at the top of the base plate with the holes on the top of the thermostat then rotate on the hinge point down to close 4 Attach the thermostat to back plate Locate the HVAC Interface Module so that it can connect to the other end of the existing wire from the thermostat After removing the cover secure the HVAC Interface Module to the wall the HVAC equipment chassis or HV...

Страница 5: ...tage heating 2 stage cooling fan and 2 accessories Heat pump dual fuel systems Up to 4 stage heating 2 stage cooling fan reversing valve and 1 accessory Accessory options Humidifier dehumidifier HRV ERV ventilator W Air Conditioner or Heat Pump HVAC Interface Module Hot Water Tank Watts FloodSafe Water Detector Shutoff HRV ERV Ventilator Optional Outdoor Sensor Invita WiFi Thermostat Furnace Humid...

Страница 6: ...art 15B Jumpers Set J1 to on to power Rc Set J2 to on to power Rh2 Set J3 to on to power Rh1 Y1 Y2 G ACC1 ACC2 O B AWAY WATER LEAK DETECTED Rh1 W1 Rh2 W2 Rc Y1 Y2 G S1 S2 SEN COM S3 RH 3V3 WATER LEAK DETECTOR R J2 R J1 R ON J1J2J3 OFF Designed and assembled in Canada tekmarControls com Power 21 30 V ac dc 5 VA Class 2 Relay 30V ac dc 2A Class 2 Circuts Meets Class B ICES 003 FCC Part 15B Jumpers S...

Страница 7: ...ng Unit The thermostat operates the heat pump when the outdoor air temperature is above the balance point setting and switches to the furnace when below Up to 2 Stage Heat Pump with 2 Stage Dual Fuel HVAC Interface Module 564 Rh1 C R W1 Acc1 Acc1 Rh2 W2 Rc Y1 G Y2 To T Stat AWAY S1 S3 S2 Water Detect RH 3V3 SEN COM Acc2 O B Acc2 O B W1 C W2 R Y1 G Y2 O B 70 Air Handling Unit Essential Settings Hea...

Страница 8: ...air quality and recovers heat from exhaust air Essential Settings Accessory Relay 1 Ventilation HRV ERV Ventilator External Jumper Wires R to Acc1 R to O B HVAC Interface Module 564 Rh1 C R W1 Acc1 Acc1 Rh2 W2 Rc Y1 G Y2 HUM HUM To T Stat AWAY S1 S3 S2 Water Detect RH 3V3 SEN COM Acc2 O B Acc2 O B Humidifier The thermostat operates a humidifier to increase relative humidity Humidifier Essential Se...

Страница 9: ...r instead Room Sensor To T Stat AWAY S1 S3 S2 Water Detect RH 3V3 SEN COM V Com Rh Sen tekmar Humidity Temperature Sensor 086 The Watts FloodSafe Water Detector Shutoff LFWDS prevents catastrophic water damage in the event of a water heater leak The thermostat provides an email notification in the event that the FloodSafe Water Detector Shutoff LFWDS detects a water and shuts off the supply line t...

Страница 10: ...grayed out until a related setting is changed Step by step instructions for connecting to WiFi downloading the app and adjusting other common settings are included in the User Brochure For detailed information on thermostat oper ation refer to the operation manual available from the Invita WiFi Thermostat 564 product page tekmarControls com Invita Thermostat Settings Invita WiFi Thermostat Display...

Страница 11: ...ew energy use MENU SELECTION AWAY SCHEDULE DISPLAY TIME WIFI SETUP FAN WIFI Connected Press the button to enter the settings menu Settings menu Back to Settings menu Set min and max temperatures Set the humidifier and dehumidifier settings requires a humidifier or dehumidifier to be installed Set the ventilator run time requires an HRV or ERV Setup temperature and humidity high and low alert notif...

Страница 12: ...e system fan options 20 23 Select humidifier and dehumidifier options 21 22 Select window frost protection options This prevents moisture and frost on windows in the winter 24 Select the time to switch between heating to cooling and vice versa RELAYS 2 Heat 3 Time Delay 1 min Heat 4 Differential 3 0 F Cool 2 Differential 2 0 F Cool 2 Time Delay 1 min Y Min Run Time 2 00 min Heat 4 Time Delay 1 min...

Страница 13: ...ntial Select differential Heat 3 Time Delay Select time Heat 4 Differential Select differential Heat 4 Time Delay Select time Cool 2 Differential Select differential Cool 2 Time Delay Select time Y Min Run Time Select time Y Min Off Time Select time Dual Fuel Off On Accessory Relay 1 Off Humidifier Dehumidifier Ventilation HP Loop Valve Accessory Relay 2 Off Humidifier Dehumidifier HP Reversing Va...

Страница 14: ...s Display Indoor use only 4 to 122 F 20 to 50 C RH 90 non condensing HVAC Interface Module 40 to 122 F 40 to 50 C RH 90 non condensing outdoor use requires mounting in a NEMA 3 enclosure Environmental Do not use in presence of ammonia animal barns Power supply 21 30 V ac 6 VA Class 2 Relays 30 V ac 2 A Class 2 Circuits Humidity sensor 0 to 90 4 RH RH Output 3 3 V dc humidity sensor power 3 0 mA ma...

Страница 15: ...the Internet and be registered to a mobile app account For details on setting up and using the voice control features of you Invita WiFi Thermostat refer to the Voice Control Manual available from tekmarControls com Voice Controls Amazon Alexa and all related logos are trademarks of Amazon com Inc or its affiliates Google Google Home Android Google Play and other related marks and logos are tradem...

Страница 16: ...ser to its customers which are differ ent from or in excess of the tekmar Limited Warranty are the Purchaser s sole responsibility and obligation Purchaser shall indemnify and hold tekmar harmless from and against any and all claims liabilities and damages of any kind or nature which arise out of or are related to any such representations or warranties by Purchaser to its customers The pass throug...