background image

 

 

 

REVERSE OSMOSIS 

 

INSTALLATION AND OPERATION MANUAL 

 

Model R4X40 

 
 
 
 
 
 
 
 
 
 
 
 
 
 
 

 
 

 

 

Содержание R4X40

Страница 1: ...REVERSE OSMOSIS INSTALLATION AND OPERATION MANUAL Model R4X40...

Страница 2: ......

Страница 3: ...ty of the end user Successful long term performance of an RO system depends on proper operation and maintenance of the system This includes the initial system startup and operational startups and shut...

Страница 4: ...nt II Controls Indicators and Components III Operation A Installation B Plumbing Connections C Electrical D Startup E Control Function F Operation and Maintenance Log G Troubleshooting IV Replacement...

Страница 5: ...0 ppm TDS and pH 7 Individual membrane productivity may vary 15 May be operated on other feed waters with reduced capacity Percent Rejection is based on membrane manufactures specifications overall sy...

Страница 6: ...suspended solids sediment from the feed water Backwashing the media removes the trapped particles Backwash can be initiated by time or differential pressure Water Softener Used to remove calcium and m...

Страница 7: ...solubility Additionally the solubility is highly pH and temperature dependent Silica fouling can be prevented with chemical injection and or reduction in recovery II CONTROLS INDICATORS and COMPONENT...

Страница 8: ...Figure 1...

Страница 9: ...Figure 2 Controller Connections...

Страница 10: ...he product water line should never be restricted Membrane and or system damage may occur if the product line is blocked 3 Connect the reject water outlet to a drain The reject outlet is located behind...

Страница 11: ...rating data using the log sheet E CONTROL FUNCTION 1 When the on off switch is in the on position the inlet valve opens and the pump runs There is a five second delay between the opening of the inlet...

Страница 12: ...ater TDS The meter will automatically turn it self off after a few seconds The quality meter is powered by two AAA batteries To replace the batteries lift the meter out of the bracket and remove the b...

Страница 13: ...ED WATER TEMP FEED WATER HARDNESS FEED WATER CHLORINE LEVEL PRE FILTER INLET PRESSURE PRE FILTER OUTLET PRESSURE REMARKS Note Change the prefilter when the differential pressure increases by 5 10 psi...

Страница 14: ...and reject Slime in pipes and vessels Shock dosage of sodium bisulfite Continuous feed of low conc bisulfite at reduced pH Peracetic acid sterilization Clean with alkaline anionic surfactant Chlorine...

Страница 15: ...Low feed water temperature Adjust reject valve or replace pump Increase membrane feed pressure or heat the feed water IV REPLACEMENT PARTS LIST A list of common replacement parts is provided below Co...

Страница 16: ...e the end caps The new membranes should be installed in the same orientation as the old membranes Note It is very important that the brine seal does not flip up or roll when installing the membrane br...

Страница 17: ...perating at 50 recovery with a feed water SDI 1 R4X40 1 R4X40 2 R4X40 3 Product GPM 1 5 3 0 4 5 Reject GPM 1 5 3 0 4 5 Nominal flows for systems operating at 50 recovery with a feed water SDI 3 R4X40...

Страница 18: ...0 68 0 86 19 66 2 0 84 18 64 4 0 81 17 62 6 0 79 16 60 8 0 77 15 59 0 74 14 57 2 0 72 13 55 4 0 70 12 53 6 0 68 11 51 8 0 66 10 50 0 64 9 48 2 0 62 8 46 4 0 61 7 44 6 0 59 6 42 8 0 57 5 41 0 55 Multip...