manualshive.com logo in svg
background image

8

Service continued

Cleaning the Injector and Screen

  1)   Turn off water supply to conditioner: 
    a)  If the conditioner installation has a “three valve” by-pass 

system, first open the valve in the bypass line, then close the 

valves at the conditioner inlet and outlet.

    b)  If the conditioner has an integral by-pass valve, put it in the 

by-pass position. 

    c)  If there is only a shutoff valve near the conditioner inlet, close it.
  2)   Relieve water pressure in the conditioner by stepping the control 

into the backwash position momentarily. Return the control to 

the service position.

  3)   Unplug electrical cord from outlet.
  4)  Remove the two injector cap mounting screws. 
  5)  To replace injector and screen.
    a)  Pull the screen and injector throat/nozzle assembly out of the 

valve body.  

    b)  Insert a new injector throat/nozzle assembly, be sure they are 

sealed tightly. Install a new screen.

    c)  Apply silicone lubricant to new injector cap seal.
  6)  Replace injector cap with two mounting screws. 
  7)  Tighten screws.
  8)   Return by-pass or inlet valving to normal service position. Water 

pressure should now be applied to the conditioner, and any by-

pass line shutoff.

  9)   Check for leaks at all seal areas. Check the drain seal with the 

control in the backwash position.

 10)  Plug electrical cord into outlet.
 11)   Set time of day and cycle the control valve manually to assure 

proper function. Make sure control valve is returned to the ser-

vice position.

 12)   Make sure there is enough salt in the brine tank.
 13)   Start regeneration cycle manually if water is hard.

Содержание PWSYS-WH-SOFT-PRO-SE - 30K

Страница 1: ...ual for future reference Refer to enclosed for operating parameters to ensure proper use with your water supply Table of Contents Pages Important Safety Information Read All 2 Softener Anatomy 3 Specifications 4 Setup 4 Installation 5 6 Control Start up Procedures 7 Service 7 Softener Operation 8 Troubleshooting 9 Water Softener System Parts List 10 Limited Warranty 12 PWSYS SOFT PRO SE PURE WATER...

Страница 2: ...ater freezing in the system causes equipment damage Do not install in direct sunlight Ultraviolet rays from the sun may cause damage Minimum inlet water pressure is 20 psi Maximum inlet water pres sure is 125 psi Use a pressure reducing valve if necessary Sodium used in the water softening process should be considered as part of your overall dietary salt intake Contact physician if you are on a lo...

Страница 3: ...3 Softener Anatomy 1 2 3 6 4 5 7 8 Item Description 1 Valve 2 Bypass 3 Resin Tank 4 Distributor 5 Resin 6 Salt Tank Lid 7 Salt Tank 8 Faceplate Controls Not Shown Brine Valve Assembly ...

Страница 4: ...npack and check the system components for damage or missing parts Where to Install the Softener Consider the following points when determining where to install the water softener Place the system as close as possible to a sewer drain Do not install the softener where it would block access to the water heater or access to the main water shutoff water meter or electri cal panels Keep outside faucets...

Страница 5: ...section will be used as an overflow tube Step 11 7 Locate the barbed drain fitting on the back of the valve 8 Connect and route the valve drain line Use the provided tubing to attach to the valve drain fitting Use the included clamp to keep water pressure from blowing the tubing off of the fitting 9 Locate the other end of the drain tubing at a suitable drain Tie or wire the tube in place at the d...

Страница 6: ...nitize flush and condition your water softener a Remove the brine tank cover and add salt to the tank Use only nugget pellet or coarse solar salt designed for water softener use with a purity of 99 5 or higher b Add three gallons of water to the brine tank for 32K 45K 60K systems and add 5 gallons of water for 90K 120K systems c Remove the brine well cover Pour 1 1 2 ounces of common household ble...

Страница 7: ...remaining brine from the tank and packs the resin bed for softening efficiency 4 Brine Fill Brine is water saturated with large amounts of salt sodium chloride During brine fill water flows into the salt storage area after each regeneration and dissolves salt During the regeneration process hardness ions on the resin beads are replaced or exchanged for sodium ions from the brine solution 5 Service...

Страница 8: ...replace injector and screen a Pull the screen and injector throat nozzle assembly out of the valve body b Insert a new injector throat nozzle assembly be sure they are sealed tightly Install a new screen c Apply silicone lubricant to new injector cap seal 6 Replace injector cap with two mounting screws 7 Tighten screws 8 Return by pass or inlet valving to normal service position Water pressure sho...

Страница 9: ...Clean Control and Add Resin Cleaner to Resin Bed Increase Frequency of Regeneration 5 Loss of Resin Through Drain Line A Air in Water System A Assure that Well System has Proper Air Eliminator control Check for Dry Well Condition B Drain Line Flow Control is too large B Ensure Drain Line Flow Control is Sized Correctly 6 Iron in Conditioned Water A Fouled Resin Bed A Check Backwash Brine Draw and ...

Страница 10: ...mm below top of tank Item Description Not Shown See Service Manual Pro SE Control Valve Assembly 2 Brine Tank 3 4 Brine Well 4 Tank w base 5 Distributor Assembly 6 2310 Safety Brine Valve Assembly Air Check 7 3 8 Brine Line Tube 11 Fitting Tube 375 Nut Brass 12 3 8 Delrin Ferrule 13 Brass Insert 3 8 tube Parts List ...

Страница 11: ...11 ...

Страница 12: ... remedies stated in such warranties are exclusive and are the only remedies for breach of warranty EXCEPT FOR THE APPLICABLE PRODUCT WARRANTY IF ANY WATTS MAKES NO OTHER WARRANTIES EXPRESS OR IMPLIED TO THE FULLEST EXTENT PERMITTED BY APPLICABLE LAW WATTS HEREBY SPECIFICALLY DISCLAIMS ALL OTHER WARRANTIES EXPRESS OR IMPLIED INCLUDING BUT NOT LIMITED TO THE IMPLIED WARRANTIES OF MERCHANTABILITY AND...

Отзывы: