background image

5

STEP 2

Watts Chrome Top Mount  

Faucet Installation 

Gather and identify the faucet pieces.

Step A -

  Remove faucet base and faucet spout from their respective 

plastic bags . From above the sink, feed the faucet tubing 

and toggle bolt down through the 1¼" mounting hole in 

the sink. Ensure that the soft rubber gasket is uniformly 

positioned in between the base of the faucet and the top of 

the sink .

Step B -

  Align the faucet base so that the handle is on the right side 

and the base is sitting flush on the sink top . Turn the handle 

down (towards you) to the “ON” position to reveal the 

tightening screw (located where the spout will be inserted) . 

Using a Phillips head screwdriver, turn the screw clockwise 

until the toggle bolt secures the faucet base snug onto the 

sink top . 

Step C -

  Once the faucet base is securely fastened to the sink top, 

insert the faucet spout into the faucet base until it is fully 

seated. Turn the handle up (away from you) to the “OFF” 

position .

Step D -

  Connect the loose end of the 

3

8

" blue plastic tubing from 

the faucet to the 

1

4

" x 

3

8

" plastic reducing union. Connect 

the 

1

4

" blue tubing from the OUTLET SIDE of the filtration 

unit to the 

1

4

" side of the union.

MiniMuM

MaxiMuM

Mounting Hole Size

1"

1

1

4

"

Torque on Toggle Bolt

5 lb.in. (max)

Adapt-A-Valve™ Installation

Verify contents prior to installation:

( 1 ) - Plastic Adapt-a-Valve™ & Black Collet 

( 1 ) - Brass Adapter no washer 

( 1 ) - Brass Adapter with black washer  

( 1 ) - White rubber washer

Water supply line to the system must be from the cold water 

supply line only. Hot water will severely damage your system.
WARNING:  Do not use Teflon tape with the Adapt-A-Valve™. 

For 

3

8

" Configuration  

For 

1

2

" Configuration  

Step A -

  Turn off the cold water supply to the faucet by turning the 

angle stop valve completely off . 

Step B -

  Open cold water sink faucet to relieve pressure . 

Step C -

  Choosing the configuration that fits your plumbing, at-

tach the Adapt-A-Valve™ as illustrated in the four photos 

above .

STEP 3

Hot

Supply

Cold

Supply

Hot

Supply

Cold

Supply

(With Brass Fittings) 

* Insert White Washer

(Without Brass Fittings) 

1

2

" Configuration

Содержание PWROKC4

Страница 1: ...Faucet Installation 5 Adapt A Valve Installation 5 Drain Saddle Installation 6 Green Tube Connection From RO Module To The Adapt A Valve 6 Reverse Osmosis Module Mounting 6 Red Tube Connection From The Faucet To The Flow Restrictor 6 Check Air Pressure in the Tank 7 Tank Ball Valve Installation 7 Blue Tube Connection From RO Module To The Tank 7 Blue Tube Connection From RO Module To The Faucet 7 ...

Страница 2: ...other materials that cause bad taste and odor are greatly reduced Stage 3 Membrane recommended change 2 5 years Stage 3 is the heart of the reverse osmosis system the RO membrane This semi permeable membrane will ef fectively take out TDS Sodium and heavy metals such as arsenic copper and lead as well as Cysts such as Giar dia and cryptosporidium Because the process of making this high quality dri...

Страница 3: ... filters that can be used if copper tubing fol lows the Reverse Osmosis unit Be sure to follow any state province or local regulations during installation Drill a Hole for the Faucet in a Porcelain Sink Note Most sinks are predrilled with 1 or 1 diameter hole that you can use for your RO faucet If you are already using it for a sprayer or soap dispenser see Step 2 Caution Porcelain sinks are extre...

Страница 4: ...dges be removed before inserting into fitting Fitting grips before it seals Ensure tube is pushed into the tube stop Push the tube into the fitting to the tube stop The collet gripper has stainless steel teeth which hold the tube firmly in position while the O ring provides a perma nent leak proof seal Pull on the tube to check that it is secure It is a good practice to test the system prior to le...

Страница 5: ...to the OFF position Step D Connect the loose end of the 3 8 blue plastic tubing from the faucet to the 1 4 x 3 8 plastic reducing union Connect the 1 4 blue tubing from the OUTLET SIDE of the filtration unit to the 1 4 side of the union Minimum Maximum Mounting Hole Size 1 11 4 Torque on Toggle Bolt 5 lb in max Adapt A Valve Installation Verify contents prior to installation 1 Plastic Adapt a Valv...

Страница 6: ...o plug Step A Locate the drain saddle kit in the parts bag Gather the pieces of the drain saddle 1 Black compression nut 1 Semicircle bracket with opening 2 Screws 1 Foam gasket 2 Nuts for screws 1 Semicircle bracket Step B The small square black foam gasket with a circle cut out of the middle must be applied to the inside of the drain saddle Remove sticky tape backing and stick to the drain saddl...

Страница 7: ...e allowed to fill up fully in order for the ice maker system to work properly Step B Open the RO faucet and leave it open until water begins to trickle out It will come out slowly Step C After water trickles out of the faucet close the RO faucet allowing the storage tank to fill with water It may take 4 to 6 hours to fill the tank completely depending on the pro duction capability of the membrane ...

Страница 8: ...tep D Repeat this procedure for the 2nd filter cartridges When finished flush your tank completely once to remove any natural carbon fines from the RO system Check over the next 24 hours to ensure no leaks are present 6 Month System Maintenance Annual Maintenance Order filter by calling Watts at 1 800 224 1299 Item Needed 7100117 Includes 1 Sediment Filter 1 Membrane 1 Carbon Block Filter 1 GAC Fi...

Страница 9: ...sumer confidence report If you have your own well you will need to have the water evaluated The local health department or the state environmental health agency can provide a list of test kits or certified labs There are two forms of arsenic pentavalent arsenic also called As V As 5 and trivalent arsenic also called As III As 3 In well water arsenic may be pentavalent trivalent or a combination of...

Страница 10: ...e should be 5 7psi See Page 7 4 Noise Water from faucet vent hole or noise from in drain line drain Crimp or restriction Check tubing and straighten or repair as necessary Straighten all drain lines Clear blockage Cut off any excess tubing Drain tube clogged Caused from dishwasher or garbage disposal Disconnect the 3 8 black line at the drain clean the 3 8 black line out with a wire then reconnect...

Страница 11: ... 8 BLACK TUBE DRAIN 8 3 SEDIMENT FILTER 4 PRE CARBON FILTER 5 RO MEMBRANE 6 POST CARBON FILTER 7 17 16 18 1 4 x 1 4 UNION 19 14 ITEM EDP DESCRIPTION 1 7300068 Adapt A Valve 2 7300070 Automatic Shut Off Valve 1 4 QC 3 7100469 Sediment Filter 4 7100109 Carbon Filter 5 7100125 Reverse Osmosis Membrane 6 7100462 Post Carbon Filter 7 7300034 Elbow 1 4 QC X 1 4 Stem 8 7100174 Storage Tank 3 Gal White 9 ...

Страница 12: ...warranties are exclusive and are the only remedies for breach of warranty EXCEPT FOR THE APPLICABLE PRODUCT WARRANTY IF ANY WATTS MAKES NO OTHER WARRANTIES EXPRESS OR IMPLIED TO THE FULLEST EXTENT PERMITTED BY APPLICABLE LAW WATTS HEREBY SPECIFICALLY DISCLAIMS ALL OTHER WARRANTIES EXPRESS OR IMPLIED INCLUDING BUT NOT LIMITED TO THE IMPLIED WARRANTIES OF MERCHANTABILITY AND FITNESS FOR A PARTICULAR...