STEP 6I7
– Tuesday Backwash: To regenerate on Tuesday use the UP or DOWN button until the arrow
points to Regen. If the arrow does not point to Regen a regeneration will not occur on Tuesday. Press
SET HOUR to go to STEP 7I7.
STEP 7I7
– Wednesday Backwash: To regenerate on Wednesday use the UP or DOWN button until the
arrow points to Regen. If the arrow does not point to Regen a regeneration will not occur on Wednesday.
Press SET HOUR to go to STEP 8I7.
STEP 8I7
– Thursday Backwash: To regenerate on Thursday use the UP or DOWN button until the arrow
points to Regen. If the arrow does not point to Regen a regeneration will not occur on Thursday. Press
SET HOUR to go to STEP 9I7.
STEP 9I7
– Friday Backwash: To regenerate on Friday use the UP or DOWN button until the arrow points
to Regen. If the arrow does not point to Regen a regeneration will not occur on Friday. Press SET HOUR
to go to STEP 10I7.
STEP 10I7
– Saturday Backwash: To backwash on Saturday use the UP or DOWN button until the arrow
points to Regen. If the arrow does not point to Regen a regeneration will not occur on Saturday. Press
SET HOUR to exit Installer Displays & Settings.
NOTE: If all arrows are turned off in d1-d7, Days to Regen in the User Displays will always read 7
and a regeneration will never occur.
User Displays
General Operation
When the system is operating one of two displays will be shown. Pressing UP or DOWN button will alter-
nate between the displays. One of the displays is always the current time of day (to the nearest hour).
The second display is the days remaining until the next backwash. If the days remaining is equal to one,
a backwash will occur at the next preset regeneration time. The user can scroll between displays as
desired.
If the system has called for a backwash that will occur at the preset time of backwash, the arrow will
point to Regen.
Regeneration Mode
Typically a system is set to regenerate at a time of low water usage. An example of a time with low water
usage is when a household is asleep. If there is a demand for water when the system is backwash,
untreated water will be used.
STEP 6I7
STEP 7I7
STEP 8I7
STEP 9I7
STEP 10I7
Return to
Normal Mode
SET
HOUR
Regen
Min. Fill
Regen
Hour
Time-Hour
PM
Days To Regen
SET
HOUR
Regen
Min. Fill
Regen
Hour
Time-Hour
PM
Days To Regen
SET
HOUR
Regen
Min. Fill
Regen
Hour
Time-Hour
PM
Days To Regen
SET
HOUR
Regen
Min. Fill
Regen
Hour
Time-Hour
PM
Days To Regen
SET
HOUR
Regen
Min. Fill
Regen
Hour
Time-Hour
PM
Days To Regen
or
SET
HOUR
Regen
Min. Fill
Regen
Hour
Time-Hour
PM
Days To Regen
SET
HOUR
Regen
Min. Fill
Regen
Hour
Time-Hour
PM
Days To Regen
SET
HOUR
Regen
Min. Fill
Regen
Hour
Time-Hour
PM
Days To Regen