manualshive.com logo in svg
background image

Operation & Maintenance Manual

AquaSolve

®

Anti-Scale Systems
Chemical-Free, Salt-Free  
Scale Prevention

M8408-COM (12GPM)
M8410-COM (20 GPM)

© 2019 PVI

PVI Industries

  •  3209 Galvez Avenue  •  Fort Worth, TX 76111

USA:

 T: (817) 335-9531 • Toll Free: (800) 784-8326 • PVI.com

Technical Support

  •  (800) 433-5654  •  Mon-Fri, 8 am - 5 pm EST

Manufacturing ASME Commercial Water Heaters Since 1961

IOM-M8408_M8410-COM_EN

Important: Read this Manual BEFORE using this equipment. Failure  
to read and follow all safety and use information can result in death, 
serious personal injury, property damage, or damage to the  
equipment. Keep this Manual for future reference.

Содержание PVI AquaSolve M8408-COM

Страница 1: ...5 9531 Toll Free 800 784 8326 PVI com Technical Support 800 433 5654 Mon Fri 8 am 5 pm EST Manufacturing ASME Commercial Water Heaters Since 1961 IOM M8408_M8410 COM_EN Important Read this Manual BEFO...

Страница 2: ...e require adjustments AquaSolve Benefits Chemical free scale prevention and protection converts hardness minerals to harmless inactive microscopic crystals making AquaSolve an effec tive alternative t...

Страница 3: ...uaSolve there are some unique requirements for using AquaSolve in conjunction with other forms of water treatment 1 AquaSolve must be the last stage in the treatment chain Do not install any filters a...

Страница 4: ...scaling While silica tends to have a less significant effect on scale formation than other miner als it can act as a binder that makes water spots and scale residue outside the plumbing system difficu...

Страница 5: ...o isolate the tank for servicing A full bypass should be installed so that the full service flow can be routed around the system as needed for servicing NOTICE Install Piping Connect the inlet and out...

Страница 6: ...f these objects protect remove them or use the outlet hose to drain option 6 Connect the outlet of the AquaSolve system to the cold water supply to the building 7 Open the supply valve to the AquaSolv...

Страница 7: ...ng the media You need to take it out in small bites If you let the whole pipe hose fill with media it will plug up You need to let slugs of water flush out the pipe as you go 11 When all the old media...

Страница 8: ...ring any part or parts to our satisfaction that prove defective within the warranty period stated above Such replacement parts will be delivered to the owner F O B nearest factory at no cost excluding...