PROBLEM

CAUSE

CORRECTION

No soft water

1. No salt in the storage tank.

Refill with salt and then use RECHARGE NOW feature.

No soft water & dis-
play is blank

1. Transformer unplugged at wall outlet, or

power cable disconnected from back of
electronic board or transformer malfunction.

Check for loss of power and correct.  Reset electronic
controls and then use RECHARGE NOW feature.

2. Fuse blown, circuit breaker popped, or cir-

cuit switched off (See “Power Outage
Memory” on Page 11).

Replace fuse, reset circuit breaker, or switch circuit on,
and then use RECHARGE NOW feature.

3. Electronic control board malfunction.

Replace electronic control board (See Page 23).

No soft water & salt
level not dropping

1. Salt storage tank “bridged”.

Refer to “Breaking a Salt Bridge” section to break.

2. Bypass valve(s) in “bypass” position.

Move bypass valve(s) to “service” position.

No soft water & salt
storage tank full of
water,
water running to
drain while unit is in
the soft water cycle

1. Dirty, plugged or damaged nozzle & venturi

assembly

Take apart, clean and inspect nozzle & venturi (See
“Cleaning the Nozzle & Venturi” section.

2. Inner valve fault causing leak.

Replace seals and rotor.

3. Valve drain hose is plugged.

Hose must not have any kinks, sharp bends or any water
flow blockage (See “Valve Drain Requirements” section.

4. Valve drain line and Salt Storage Tank

overflow drain connected together by a tee.

Disconnect tee and run separate drain lines.

5. Low or high system water pressure (low

pressure may disrupt brine draw during
recharge, high pressure may cause inner
valve parts failure).

If pressure is low, increase well pump output to a mini-
mum 20 psi.  If daytime pressure is over 100 psi, add a
pressure reducing valve in the supply pipe to the soften-
er.  Contact a licensed plumber.

6. Brine float dirty or broken.

Clean or replace Brine Valve Float Assembly.

7. Leak between valve and resin tank.

Replace o-rings between resin tank and valve.

Water hard some-
times

1. Incorrect time set.

Check and change time setting.

2. Incorrect water hardness set.

Refer to “Set Water Hardness” section to set correctly.

3. Incorrect model code programmed.

Refer to “Program the Water Softener” section to set cor-
rectly.

4. Hot water being used when softener is

regenerating.

Avoid using hot water while the softener is regenerating,
as the water heater will fill with hard water.

5. Possible increase in water hardness.

Test untreated water for hardness and iron, and program
the water softener accordingly (See “Set Water
Hardness”) section to set.

6. Leaking faucet or toilet valve.  Excessive

water usage.

A small leak can waste hundreds of gallons of water in a
few days.  Fix all leaks and always fully close faucets.

Iron in water

1. Clear water iron in water supply.

Test untreated water for hardness and iron, and program
the water softener accordingly (See “Set Water
Hardness”) section to set.

2. Iron in soft water.

Clean resin bed with Resin Bed Cleaner.  Follow instruc-
tions on package.

3. Bacterial or organic bound iron.

Cannot be treated by water softener.

Resin in house hold
plumbing

1. Crack in distributor or riser tube.

Replace resin tank assembly.

Salt storage tank
leaking

1. Crack in brine tank.

Replace salt storage tank assembly.

Motor stalled or
clicking

1. Motor malfunction or internal valve fault

causing high torque on motor.

a. Replace rotor/seal.
b. Replace motor & switch.

Error code E1, E3 or
E4 appears

1. Fault in wiring harness or connections to

position switch.

Replace wiring harness or connections to position switch.

2. Fault in switch.

Replace switch.

3. Fault in valve causing high torque.

Replace rotor/seal.

4. Motor inoperative.

Replace motor.

Error code E5

1. Electronic control malfunction.

Replace electronic control board.

18

Troubleshooting Guide

PROBLEM

CAUSE

CORRECTION

No soft water

1. No salt in the storage tank.

Refill with salt and then use RECHARGE NOW feature.

No soft water & dis-
play is blank

1. Transformer unplugged at wall outlet, or

power cable disconnected from back of
electronic board or transformer malfunction.

Check for loss of power and correct.  Reset electronic
controls and then use RECHARGE NOW feature.

2. Fuse blown, circuit breaker popped, or cir-

cuit switched off (See “Power Outage
Memory” on Page 11).

Replace fuse, reset circuit breaker, or switch circuit on,
and then use RECHARGE NOW feature.

3. Electronic control board malfunction.

Replace electronic control board (See Page 23).

No soft water & salt
level not dropping

1. Salt storage tank “bridged”.

Refer to “Breaking a Salt Bridge” section to break.

2. Bypass valve(s) in “bypass” position.

Move bypass valve(s) to “service” position.

No soft water & salt
storage tank full of
water,
water running to
drain while unit is in
the soft water cycle

1. Dirty, plugged or damaged nozzle & venturi

assembly

Take apart, clean and inspect nozzle & venturi (See
“Cleaning the Nozzle & Venturi” section.

2. Inner valve fault causing leak.

Replace seals and rotor.

3. Valve drain hose is plugged.

Hose must not have any kinks, sharp bends or any water
flow blockage (See “Valve Drain Requirements” section.

4. Valve drain line and Salt Storage Tank

overflow drain connected together by a tee.

Disconnect tee and run separate drain lines.

5. Low or high system water pressure (low

pressure may disrupt brine draw during
recharge, high pressure may cause inner
valve parts failure).

If pressure is low, increase well pump output to a mini-
mum 20 psi.  If daytime pressure is over 100 psi, add a
pressure reducing valve in the supply pipe to the soften-
er.  Contact a licensed plumber.

6. Brine float dirty or broken.

Clean or replace Brine Valve Float Assembly.

7. Leak between valve and resin tank.

Replace o-rings between resin tank and valve.

Water hard some-
times

1. Incorrect time set.

Check and change time setting.

2. Incorrect water hardness set.

Refer to “Set Water Hardness” section to set correctly.

3. Incorrect model code programmed.

Refer to “Program the Water Softener” section to set cor-
rectly.

4. Hot water being used when softener is

regenerating.

Avoid using hot water while the softener is regenerating,
as the water heater will fill with hard water.

5. Possible increase in water hardness.

Test untreated water for hardness and iron, and program
the water softener accordingly (See “Set Water
Hardness”) section to set.

6. Leaking faucet or toilet valve.  Excessive

water usage.

A small leak can waste hundreds of gallons of water in a
few days.  Fix all leaks and always fully close faucets.

Iron in water

1. Clear water iron in water supply.

Test untreated water for hardness and iron, and program
the water softener accordingly (See “Set Water
Hardness”) section to set.

2. Iron in soft water.

Clean resin bed with Resin Bed Cleaner.  Follow instruc-
tions on package.

3. Bacterial or organic bound iron.

Cannot be treated by water softener.

Resin in house hold
plumbing

1. Crack in distributor or riser tube.

Replace resin tank assembly.

Salt storage tank
leaking

1. Crack in brine tank.

Replace salt storage tank assembly.

Motor stalled or
clicking

1. Motor malfunction or internal valve fault

causing high torque on motor.

a. Replace rotor/seal.
b. Replace motor & switch.

Error code E1, E3 or
E4 appears

1. Fault in wiring harness or connections to

position switch.

Replace wiring harness or connections to position switch.

2. Fault in switch.

Replace switch.

3. Fault in valve causing high torque.

Replace rotor/seal.

4. Motor inoperative.

Replace motor.

Error code E5

1. Electronic control malfunction.

Replace electronic control board.

18

Troubleshooting Guide

PROBLEM

CAUSE

CORRECTION

No soft water

1. No salt in the storage tank.

Refill with salt and then use RECHARGE NOW feature.

No soft water & dis-
play is blank

1. Transformer unplugged at wall outlet, or

power cable disconnected from back of
electronic board or transformer malfunction.

Check for loss of power and correct.  Reset electronic
controls and then use RECHARGE NOW feature.

2. Fuse blown, circuit breaker popped, or cir-

cuit switched off (See “Power Outage
Memory” on Page 11).

Replace fuse, reset circuit breaker, or switch circuit on,
and then use RECHARGE NOW feature.

3. Electronic control board malfunction.

Replace electronic control board (See Page 23).

No soft water & salt
level not dropping

1. Salt storage tank “bridged”.

Refer to “Breaking a Salt Bridge” section to break.

2. Bypass valve(s) in “bypass” position.

Move bypass valve(s) to “service” position.

No soft water & salt
storage tank full of
water,
water running to
drain while unit is in
the soft water cycle

1. Dirty, plugged or damaged nozzle & venturi

assembly

Take apart, clean and inspect nozzle & venturi (See
“Cleaning the Nozzle & Venturi” section.

2. Inner valve fault causing leak.

Replace seals and rotor.

3. Valve drain hose is plugged.

Hose must not have any kinks, sharp bends or any water
flow blockage (See “Valve Drain Requirements” section.

4. Valve drain line and Salt Storage Tank

overflow drain connected together by a tee.

Disconnect tee and run separate drain lines.

5. Low or high system water pressure (low

pressure may disrupt brine draw during
recharge, high pressure may cause inner
valve parts failure).

If pressure is low, increase well pump output to a mini-
mum 20 psi.  If daytime pressure is over 100 psi, add a
pressure reducing valve in the supply pipe to the soften-
er.  Contact a licensed plumber.

6. Brine float dirty or broken.

Clean or replace Brine Valve Float Assembly.

7. Leak between valve and resin tank.

Replace o-rings between resin tank and valve.

Water hard some-
times

1. Incorrect time set.

Check and change time setting.

2. Incorrect water hardness set.

Refer to “Set Water Hardness” section to set correctly.

3. Incorrect model code programmed.

Refer to “Program the Water Softener” section to set cor-
rectly.

4. Hot water being used when softener is

regenerating.

Avoid using hot water while the softener is regenerating,
as the water heater will fill with hard water.

5. Possible increase in water hardness.

Test untreated water for hardness and iron, and program
the water softener accordingly (See “Set Water
Hardness”) section to set.

6. Leaking faucet or toilet valve.  Excessive

water usage.

A small leak can waste hundreds of gallons of water in a
few days.  Fix all leaks and always fully close faucets.

Iron in water

1. Clear water iron in water supply.

Test untreated water for hardness and iron, and program
the water softener accordingly (See “Set Water
Hardness”) section to set.

2. Iron in soft water.

Clean resin bed with Resin Bed Cleaner.  Follow instruc-
tions on package.

3. Bacterial or organic bound iron.

Cannot be treated by water softener.

Resin in house hold
plumbing

1. Crack in distributor or riser tube.

Replace resin tank assembly.

Salt storage tank
leaking

1. Crack in brine tank.

Replace salt storage tank assembly.

Motor stalled or
clicking

1. Motor malfunction or internal valve fault

causing high torque on motor.

a. Replace rotor/seal.
b. Replace motor & switch.

Error code E1, E3 or
E4 appears

1. Fault in wiring harness or connections to

position switch.

Replace wiring harness or connections to position switch.

2. Fault in switch.

Replace switch.

3. Fault in valve causing high torque.

Replace rotor/seal.

4. Motor inoperative.

Replace motor.

Error code E5

1. Electronic control malfunction.

Replace electronic control board.

Call for service

Call for service

12

Содержание PVI Aqua Solve Family

Страница 1: ...INSTALLATION MANUAL Aqua Solve Family AQS 9 Aqua Solve Large AQS 14 400498 05 15...

Страница 2: ...er is on the underside of the salt lid 2 Remove all packaging parts from inside the unit 3 If you need to remove the valve cover for ease of installation follow the instructions carefully To remove va...

Страница 3: ...1 If ordered with softener Please Remember Only use tablet or pellet salt in your softener 3 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 IDENTIFYING MAJOR PARTS OF YOUR WATER SOFTENER NO Description Quantity...

Страница 4: ...occur Do not attempt to treat water over 49 C Freezing or hot water damage will void your warranty Avoid installing in direct sunlight Excessive sun heat may cause distortion or other damage to non m...

Страница 5: ...metre INSTALLATION OF YOUR WATER SOFTENER PLANNING AND SITING THE INSTALLATION The installation of a water softener is relatively easy but we recommend that this work is undertaken by an authorised ag...

Страница 6: ...ight ends may be connected to isolating valves or elbow unions Fit the filter discs into the straight union end of the inlet outlet hoses DRAIN OUTLET OVERFLOW CONNECTION Insert the rubber grommet int...

Страница 7: ...utlet THE UNIT WORKS ON 24V ONLY DO NOT CONNECT WITHOUT THE TRANSFORMER 7 STEP BY STEP GUIDE TO PLUMBING THE SOFTENER CONTINUED CONNECT TRANSFORMER 1 Connect the power cable leads to the two terminals...

Страница 8: ...ot show in the display press the SELECT MENU button a few times until they do 1 Press the p UP or q DOWN buttons to set the present time Up moves the display ahead down sets the time back FIG 19 B SET...

Страница 9: ...set salt level each time salt is added to the water softener To set this monitor system If you completed the previous step the words SET FIG 21 Recommended Not recommended C SET RECHARGE REGENERATION...

Страница 10: ...HT initiated FIG 25 RECHARGE NOW At times of greater than normal water use such as when you have guests you could run out of conditioned water before the next scheduled recharge If this happens you ma...

Страница 11: ...e the resin bed is not recharged and hard water will result If the storage tank is full of salt it is difficult to tell if you have a salt bridge A bridge may be underneath loose salt Take a broom han...

Страница 12: ...e See Valve Drain Requirements section 4 Valve drain line and Salt Storage Tank overflow drain connected together by a tee Disconnect tee and run separate drain lines 5 Low or high system water pressu...

Страница 13: ...el code 2 Press the p UP button a few times if necessary to display a flashing SoS 3 Press the SELECT MENU button and the elec tronic controller will restart 4 Set the present time hardness etc as des...

Страница 14: ...14 NOTES...

Страница 15: ...NOTES 15...

Страница 16: ......

Отзывы: