Watts PVI AQS-14 Скачать руководство пользователя страница 8

10

Programming the Water Softener

UP button

DOWN button

Low Salt
LED Indicator

Display

SELECT / MENU button

FIG. 16

RECHARGE button

FIG. 18

When the transformer is plugged into the electrical
outlet, a model code and a test number (example:
J2.0), begin to flash in the faceplate display (See
Figure 17).  Then,  “12:00” and the words “SET TIME"
begin to flash.

NOTE:

If “- - - -” shows in the display, press the 

p

UP

or 

q

DOWN button until the model code (See

table below) shows in the display.  Then,
press the SELECT / MENU button to set, and
change to the flashing “SET TIME" display.

A. SET PRESENT TIME OF DAY

If the words “SET TIME" do not show in the display,
press the SELECT / MENU button a few times until
they do.

1

. Press the 

p

UP or 

q

DOWN buttons to set the

present time.  Up moves the display ahead; down
sets the time back.

FIG. 19

B. SET WATER HARDNESS NUMBER

If you completed the previous step, the words “SET
HARDNESS" should show in the display.  Otherwise,
press the SELECT / MENU button several times until
they do.

1

. Press the 

p

UP or 

q

DOWN buttons to set the

hardness of your water supply, in grains per gallon.
The default is 25.  See table below for other units.

2

. When finished setting your water’s hardness num-

ber, press the SELECT / MENU button, and the dis-
play will change to show the “Set Recharge Time”
screen.

FIG. 17

NOTE:

Press buttons and quickly release to slowly
advance the display.  Hold the buttons down
for fast advance.

2

. When the correct time is displayed, press the

SELECT / MENU button, and the display will
change to show the “Hardness” screen.

Model

Code

RBS-9ED

SR9

RBS-14ED

Sr14

RBS-

24ED

S

R24

10

Programming the Water Softener

UP button

DOWN button

Low Salt
LED Indicator

Display

SELECT / MENU button

FIG. 16

RECHARGE button

FIG. 18

When the transformer is plugged into the electrical
outlet, a model code and a test number (example:
J2.0), begin to flash in the faceplate display (See
Figure 17).  Then,  “12:00” and the words “SET TIME"
begin to flash.

NOTE:

If “- - - -” shows in the display, press the 

p

UP

or 

q

DOWN button until the model code (See

table below) shows in the display.  Then,
press the SELECT / MENU button to set, and
change to the flashing “SET TIME" display.

A. SET PRESENT TIME OF DAY

If the words “SET TIME" do not show in the display,
press the SELECT / MENU button a few times until
they do.

1

. Press the 

p

UP or 

q

DOWN buttons to set the

present time.  Up moves the display ahead; down
sets the time back.

FIG. 19

B. SET WATER HARDNESS NUMBER

If you completed the previous step, the words “SET
HARDNESS" should show in the display.  Otherwise,
press the SELECT / MENU button several times until
they do.

1

. Press the 

p

UP or 

q

DOWN buttons to set the

hardness of your water supply, in grains per gallon.
The default is 25.  See table below for other units.

2

. When finished setting your water’s hardness num-

ber, press the SELECT / MENU button, and the dis-
play will change to show the “Set Recharge Time”
screen.

FIG. 17

NOTE:

Press buttons and quickly release to slowly
advance the display.  Hold the buttons down
for fast advance.

2

. When the correct time is displayed, press the

SELECT / MENU button, and the display will
change to show the “Hardness” screen.

Model

Code

RBS-9ED

SR9

RBS-14ED

Sr14

RBS-

24ED

S

R24

10

Programming the Water Softener

UP button

DOWN button

Low Salt
LED Indicator

Display

SELECT / MENU button

FIG. 16

RECHARGE button

FIG. 18

When the transformer is plugged into the electrical
outlet, a model code and a test number (example:
J2.0), begin to flash in the faceplate display (See
Figure 17).  Then,  “12:00” and the words “SET TIME"
begin to flash.

NOTE:

If “- - - -” shows in the display, press the 

p

UP

or 

q

DOWN button until the model code (See

table below) shows in the display.  Then,
press the SELECT / MENU button to set, and
change to the flashing “SET TIME" display.

A. SET PRESENT TIME OF DAY

If the words “SET TIME" do not show in the display,
press the SELECT / MENU button a few times until
they do.

1

. Press the 

p

UP or 

q

DOWN buttons to set the

present time.  Up moves the display ahead; down
sets the time back.

FIG. 19

B. SET WATER HARDNESS NUMBER

If you completed the previous step, the words “SET
HARDNESS" should show in the display.  Otherwise,
press the SELECT / MENU button several times until
they do.

1

. Press the 

p

UP or 

q

DOWN buttons to set the

hardness of your water supply, in grains per gallon.
The default is 25.  See table below for other units.

2

. When finished setting your water’s hardness num-

ber, press the SELECT / MENU button, and the dis-
play will change to show the “Set Recharge Time”
screen.

FIG. 17

NOTE:

Press buttons and quickly release to slowly
advance the display.  Hold the buttons down
for fast advance.

2

. When the correct time is displayed, press the

SELECT / MENU button, and the display will
change to show the “Hardness” screen.

Model

Code

RBS-9ED

SR9

RBS-14ED

Sr14

RBS-

24ED

S

R24

When the transformer is plugged into the electrical
outlet, a model code and a test number (example:
J2.0), begin to flash in the faceplate display (See
Figure 17). Then, “12:00” and the words “SET TIME”
begin to flash.
NOTE:  If “- - - -” shows in the display, press the   UP 

or   DOWN button until the model code (See 
table below) shows in the display. Then, 
press the SELECT/MENU button to set, and 
change to the flashing “SET TIME” display.

A. SET PRESENT TIME OF DAY

If the words “SET TIME” do not show in the display,
press the SELECT/MENU button a few times until
they do.
1.   Press  the   UP or   DOWN buttons to set the 

present time. Up moves the display ahead; down 
sets the time back.

B. SET WATER HARDNESS NUMBER

If you completed the previous step, the words “SET
HARDNESS” should show in the display. Otherwise,
press the SELECT/MENU button several times until
they do.

10

Programming the Water Softener

UP button

DOWN button

Low Salt
LED Indicator

Display

SELECT / MENU button

FIG. 16

RECHARGE button

FIG. 18

When the transformer is plugged into the electrical
outlet, a model code and a test number (example:
J2.0), begin to flash in the faceplate display (See
Figure 17).  Then,  “12:00” and the words “SET TIME"
begin to flash.

NOTE:

If “- - - -” shows in the display, press the 

p

UP

or 

q

DOWN button until the model code (See

table below) shows in the display.  Then,
press the SELECT / MENU button to set, and
change to the flashing “SET TIME" display.

A. SET PRESENT TIME OF DAY

If the words “SET TIME" do not show in the display,
press the SELECT / MENU button a few times until
they do.

1

. Press the 

p

UP or 

q

DOWN buttons to set the

present time.  Up moves the display ahead; down
sets the time back.

FIG. 19

B. SET WATER HARDNESS NUMBER

If you completed the previous step, the words “SET
HARDNESS" should show in the display.  Otherwise,
press the SELECT / MENU button several times until
they do.

1

. Press the 

p

UP or 

q

DOWN buttons to set the

hardness of your water supply, in grains per gallon.
The default is 25.  See table below for other units.

2

. When finished setting your water’s hardness num-

ber, press the SELECT / MENU button, and the dis-
play will change to show the “Set Recharge Time”
screen.

FIG. 17

NOTE:

Press buttons and quickly release to slowly
advance the display.  Hold the buttons down
for fast advance.

2

. When the correct time is displayed, press the

SELECT / MENU button, and the display will
change to show the “Hardness” screen.

Model

Code

RBS-9ED

SR9

RBS-14ED

Sr14

RBS-

24ED

S

R24

1.    Press  the   UP or   DOWN buttons to set the 

hardness of your water supply, in grains per gallon. 
The default is 25. See below for conversion:

   Conversion PPM to Grains 

Setting= ppm x 0.0584

2.   When finished setting your water’s hardness number, 

press the SELECT/MENU button, and the display 
will change to show the “Set Recharge Time” 
screen.

NOTE:  Press buttons and quickly release to slowly 

advance the display. Hold the buttons 
down for fast advance.

2.  When the correct time is displayed, press the 

SELECT/MENU button, and the display will 
change to show the “Hardness” screen.

AQS-9

AQS-14

8

Содержание PVI AQS-14

Страница 1: ...INSTALLATION MANUAL Aqua Solve Family AQS 9 Aqua Solve Large AQS 14 400498 05 15 ...

Страница 2: ...ber is on the underside of the salt lid 2 Remove all packaging parts from inside the unit 3 If you need to remove the valve cover for ease of installation follow the instructions carefully To remove valve cover pull towards you slowly taking care not to pull off the wire connections Please note that the valve cover is connected to the valve motor so cannot be removed fully Please Remember Only use...

Страница 3: ...11 If ordered with softener Please Remember Only use tablet or pellet salt in your softener 3 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 IDENTIFYING MAJOR PARTS OF YOUR WATER SOFTENER NO Description Quantity Part No 1 Easy Install Tees incorporates check value 1 pair G0817 2 Drain Overflow Tubing 1 7208718 3 Overflow Elbow 1 1103200 4 Overflow Grommet 1 9003500 5 Hose Clips 2 900431 6 Water Hardness Test...

Страница 4: ...s occur Do not attempt to treat water over 49ºC Freezing or hot water damage will void your warranty Avoid installing in direct sunlight Excessive sun heat may cause distortion or other damage to non metallic parts Maximum allowable inlet water pressure is 4 76 bar If the daytime pressure exceeds 4 76 bar a pressure reducing valve is recommended adding a pressure reducing valve may reduce the flow...

Страница 5: ... metre INSTALLATION OF YOUR WATER SOFTENER PLANNING AND SITING THE INSTALLATION The installation of a water softener is relatively easy but we recommend that this work is undertaken by an authorised agent Where possible the water softener should be sited close to the rising main allowing for any required hard water draw off points i e drinking tap and outside tap Keep the drain run as short as pos...

Страница 6: ...aight ends may be connected to isolating valves or elbow unions Fit the filter discs into the straight union end of the inlet outlet hoses DRAIN OUTLET OVERFLOW CONNECTION Insert the rubber grommet into the overflow socket situated 2 3 of the way up the rear of the water softener cabinet Only insert the overflow adaptor using the silicone grease provided once the grommet is secure Cut two lengths ...

Страница 7: ...outlet THE UNIT WORKS ON 24V ONLY DO NOT CONNECT WITHOUT THE TRANSFORMER 7 STEP BY STEP GUIDE TO PLUMBING THE SOFTENER CONTINUED CONNECT TRANSFORMER 1 Connect the power cable leads to the two terminals on the transformer NOTE Check to be sure all lead wire connections are secure on the back of the faceplate CAUTION Be sure all wiring is away from the valve gear and motor area which rotates during ...

Страница 8: ...not show in the display press the SELECT MENU button a few times until they do 1 Press the p UP or q DOWN buttons to set the present time Up moves the display ahead down sets the time back FIG 19 B SET WATER HARDNESS NUMBER If you completed the previous step the words SET HARDNESS should show in the display Otherwise press the SELECT MENU button several times until they do 1 Press the p UP or q DO...

Страница 9: ...t set salt level each time salt is added to the water softener To set this monitor system If you completed the previous step the words SET FIG 21 Recommended Not recommended C SET RECHARGE REGENERATION START TIME If you completed the previous step the words SET RECHARGE TIME should show in the display Otherwise press the SELECT MENU button several times until they do 11 FIG 20 C SET RECHARGE REGEN...

Страница 10: ...GHT initiated FIG 25 RECHARGE NOW At times of greater than normal water use such as when you have guests you could run out of conditioned water before the next scheduled recharge If this happens you may want to initiate an immediate regeneration as follows 1 Press the RECHARGE button and hold for 3 seconds until the words RECHARGE NOW flash in the display The softener enters the fill cycle of rege...

Страница 11: ...ne the resin bed is not recharged and hard water will result If the storage tank is full of salt it is difficult to tell if you have a salt bridge A bridge may be underneath loose salt Take a broom handle or like tool and hold it next to the water softener Measure the dis tance from the floor to the rim of the water softener Then gently push the broom handle straight down into the salt If a hard o...

Страница 12: ...ge See Valve Drain Requirements section 4 Valve drain line and Salt Storage Tank overflow drain connected together by a tee Disconnect tee and run separate drain lines 5 Low or high system water pressure low pressure may disrupt brine draw during recharge high pressure may cause inner valve parts failure If pressure is low increase well pump output to a mini mum 20 psi If daytime pressure is over ...

Страница 13: ...del code 2 Press the p UP button a few times if necessary to display a flashing SoS 3 Press the SELECT MENU button and the elec tronic controller will restart 4 Set the present time hardness etc as described in this manual FIG 49 RESETTING TO FACTORY DEFAULTS To reset the electronic controller to its factory default for all settings time hardness etc 1 Press the SELECT MENU button and hold it unti...

Страница 14: ...14 NOTES ...

Страница 15: ...NOTES 15 ...

Страница 16: ......

Отзывы: