5
II. Controls, Indicators, and
Components
(See Figure 1)
A. Controller - Controls the operation of the system and displays
the product water quality.
B. Reject Control Valve - Controls the amount of reject flow.
C. Reject Recycle Control Valve – Controls the amount of reject
recycle flow.
D. Pump Discharge Valve - Used to throttle the pump.
E. Prefilter Pressure Gauges - Indicates the inlet and outlet pres-
sure of the prefilter. The difference between these two gauges is
the prefilter differential pressure.
F. Pump Discharge Pressure Gauge - Indicates the pump dis-
charge pressure.
G. Reject Pressure Gauge - Indicates the reject pressure.
H. Reject Flow Meter - Indicates the reject flow rate in gallons per
minute (gpm).
I. Product Flow Meter - Indicates the product flow rate in gallons
per minute (gpm).
J. Reject Recycle Flow Meter – Indicates the reject recycle flow
rate in gallons per minute (gpm).
K. Prefilter Housing - Contains the RO prefilter.
L. Automatic Inlet Valve - Opens when pump is on and closes
when the pump is off.
M. Low Pressure Switch - Sends a signal to the controller if the
pump suction pressure is low.
N. RO Feed Pump - Pressurizes the RO feed water.
O. RO Membrane Vessels - Contains the RO membranes.
Figure 1. General System Component Identification
Содержание Pure Water PWR4021 Series
Страница 6: ...6 Figure 2 B Controller Drawing...
Страница 7: ...7 B Controller Drawing continued Figure 3...
Страница 13: ...13 Figure 6 Wiring Diagram Pictorial Schematic of a Typical ROC 4 System...
Страница 15: ...15 Figure 8 Controller Detail Terminal Board TB 3 See Fig 3 for schematic TB24V3...
Страница 20: ...20 Figure 11 Controller Programming Menu Navigation...
Страница 31: ...31 Notes...