28
MOTOR TROUBLE SHOOTING CHART (CONTINUED)
TROUBLE
CAUSE
WHAT TO DO
Unbalanced line current on polyphase
motors during normal operation
Unequal terminal volts
Check leads and connections
Single phase operation
Check for open contacts
Scraping noise
Fan rubbing air shield
Remove interference.
Fan striking insulation
Clear fan.
Loose on bedplate
Tighten holding bolts.
Noisy operation
Airgap not uniform
Check and correct bracket fits or bearing.
Rotor unbalance
Rebalance.
Hot bearings general
Bent or sprung shaft
Straighten or replace shaft.
Excessive belt pull
Decrease belt tension.
Pulleys too far away
Move pulley closer to motor bearing.
Pulley diameter too small
Use larger pulleys.
Misalignment
Correct by realignment of drive.
Hot bearings ball
Insufficient grease
Maintain proper quantity of grease in bearing.
Deterioration of grease, or lubricant contaminated
Remove old grease, wash bearings thoroughly in kerosene and replace with new grease.
Excess lubricant
Reduce quantity of grease: bearing should not be more than 1/2 filled.
Overloaded bearing
Check alignment, side and end thrust.
Broken ball or rough races
Replace bearing: first clean housing thoroughly.
These instructions do not cover all details or variations in equipment nor provide for every possible condition to be met in connection with installation, operation or maintenance. Chart courtesy
of Marathon Electric.
RO SYSTEM TROUBLE SHOOTING
PROBLEM
REMEDY
General
High Product Water TDS
Membrane expanded.
Replace membrane.
Membrane attack by chlorine
Carbon pre-filter may be exhausted. Replace with a new cartridge.
Clogged pre-filter-creates pressure drop and low reject flow.
Replace pre-filter cartridge.
Feed pressure too low.
Feed pressure must be at least 20psi.
Insufficiently flushed post-filter cartridge.
Flush post-filter with pure water.
Brine seal on membrane leaks.
Determine if seal or o-ring is bad. Replace as needed.
No Product Water or Not Enough Product Water
Feed water shut off.
Turn on feed water.
Low feed pressure.
Consider booster pump.
Feed pressure must be at least 20psi.
Replace pre-filter cartridge.
Pre-filter cartridge clogged.
Determine and correct cause; replace membrane.
Membrane fouled. Product check valve stuck.
Replace check valve fitting.
Low pump discharge pressure
Open pump discharge valve, replace pump
Содержание Pure Water PWR4021 Series
Страница 6: ...6 Figure 2 B Controller Drawing...
Страница 7: ...7 B Controller Drawing continued Figure 3...
Страница 13: ...13 Figure 6 Wiring Diagram Pictorial Schematic of a Typical ROC 4 System...
Страница 15: ...15 Figure 8 Controller Detail Terminal Board TB 3 See Fig 3 for schematic TB24V3...
Страница 20: ...20 Figure 11 Controller Programming Menu Navigation...
Страница 31: ...31 Notes...