manualshive.com logo in svg
background image

Limited Warranty

•   The  OneFlow

®

 tank system is warranted to be free of defects in materials and workmanship for 5 years from the date of original shipment.

•   The  OneFlow

®

 media is warranted for performance for a period of 2 years from the date of the original installation when installed and 

operated in accordance with the instructions in the corresponding Installation and Operation Manual.

Watts Regulator Company warrants its OneFlow

®

 cartridge systems as follows:

•   The  OneFlow

®

 cartridge system is warranted to be free of defects in materials and workmanship for 1 year from the date of original  

shipment.

•   OneFlow

®

 cartridges are warranted for performance for a period of one year from the date of original installation when installed and  

operated in accordance with the instructions in the corresponding Installation and Operation Manual.

•   Carbon replacement filter cartridges are not warranted to perform for any period of time because the service life of replacement carbon 

filter cartridges varies significantly with local water conditions and volume.

Conditions

1.   The  OneFlow

®

 system must be installed in applications with municipally supplied water adhering to EPA guidelines. 

2.  Any component failure must not result from abuse, fire, freezing or other acts of nature, violence, or improper installation.
3.  Equipment must be installed and operated in compliance with the local plumbing codes and on an approved water supply.
4.  Equipment is limited to use at water pressures and temperatures that do not exceed our published specifications.
5.   Water supply must not exceed 2.0 PPM chlorine.  For water supply exceeding 2.0 PPM chlorine, pretreatment is required.  

(Please contact your water treatment specialist.)

6.   Information, including model number, serial number, and date of installation, must be provided for any claims pertaining to equipment 

in warranty.

7.   Defective parts are subject to inspection by either Watts Regulator Company or any authorized representative before final commitment 

of warranty adjustment is made.

8.   Watts Regulator Company reserves the right to make changes or substitutions in parts or equipment with material of equal quality or value 

and of then current production.

Limitations

Our obligation under this warranty with respect to the tank or valve is limited to furnishing a replacement for, or at our option, repairing any 

part or parts to our satisfaction that prove defective within the warranty period stated above.  Such replacement parts will be delivered to the 

owner F.O.B. nearest factory, at no cost, excluding freight and local labor charges, if any.
Our obligation under this warranty with respect to the OneFlow

®

 media will be limited to furnishing a replacement for the media within two 

years from date of original installation.  Such replacement media will be delivered to the owner F.O.B. nearest factory, at no cost, excluding 

freight and local labor charges, if any.  Damage to the media due to chlorine, other oxidizers or fouling caused by local water conditions or 

any other operation outside of the limits shown under Specifications, is not covered by this warranty.
THE WARRANTY SET FORTH HEREIN IS GIVEN EXPRESSLY AND IS THE ONLY WARRANTY GIVEN BY WATTS REGULATOR COMPANY 

WITH RESPECT TO THE PRODUCT.  WATTS REGULATOR COMPANY MAKES NO OTHER WARRANTIES, EXPRESS OR IMPLIED.  WATTS 

REGULATOR COMPANY HEREBY SPECIFICALLY DISCLAIMS ALL OTHER WARRANTIES, EXPRESS OR IMPLIED, INCLUDING BUT NOT 

LIMITED TO THE IMPLIED WARRANTIES OF MERCHANTABILITY AND FITNESS FOR A PARTICULAR PURPOSE.  
The remedy described under this warranty shall constitute the sole and exclusive remedy for breach of warranty, and Watts Regulator 

Company shall not be responsible for any incidental, special or consequential damages, including without limitation, freight, handling, lost 

profits or the cost of repairing or replacing other property which is damaged if this product does not work properly, other costs resulting from 

labor charges, delays, vandalism, negligence, fouling caused by foreign material, damage from adverse water conditions, chemical, or any 

other circumstances over which Watts Regulator Company has no control.  This warranty shall be invalidated by any abuse, misuse, misap-

plication or improper installation of the product.  
Some states do not allow limitations on how long an implied warranty lasts, and some states do not allow the exclusion or limitation of inci-

dental or consequential damages.  Therefore the above limitations may not apply to you.  This warranty gives you specific legal rights, and 

you may have other rights that vary from state to state.  You should consult applicable state laws to determine your rights.  SO FAR AS IS 

CONSISTENT WITH APPLICABLE STATE LAW, ANY IMPLIED WARRANTIES THAT MAY NOT BE DISCLAIMED, INCLUDING THE IMPLIED 

WARRANTIES OF MERCHANTABILITY AND FITNESS FOR A PARTICULAR PURPOSE, ARE LIMITED IN DURATION TO THE APPLICABLE 

WARRANTY PERIODS STATED ABOVE.

IOM-OFTWH 1935 

EDP#2915853 

© 2019 Watts

USA:

  Tel: (978) 689-6066 • Fax: (978) 975-8350 • Watts.com

Canada:  

Tel: (905) 332-4090 • Fax: (905) 332-7068 • Watts.ca

Latin America:  

Tel: (52) 55-4122-0138 • Watts.com

Содержание OneFlow OFTWH

Страница 1: ...ge does not have a grain removal capacity however other contaminants present in the water will gradually degrade the effectiveness of this cartridge Change the OFTWHRM cartridge at least once every tw...

Страница 2: ...r gallon 513 ppm CaCO3 of calcium carbonate Due to variances in water chemistry 30 grains per gallon is a recommended hard ness maximum due to potential aesthetic issues related to soft scale residue...

Страница 3: ...e tubing to the equipment at this time Prior to making connection to the equipment this line will be used to facilitate flushing the system As an option a drain valve in a tee on the outlet side of th...

Страница 4: ...FPT outlet Max Pressure 90psi Max Temperature 100 F 3 4 MPT adapter req d to adapt to FPT inlet 3 4 pipe or 3 4 I D flexible reinforced beverage tubing from chlorinated municipal water supply Water S...

Страница 5: ...g if equipped and flush the new cartridge to drain or bucket for two 2 minutes or until water runs clear If no flush valve is present disconnect line from equipment to flush to drain 10 With water sup...

Страница 6: ...ts for OneFlow OFTWH Drawing ID Description 1 Housing w PR 1a O Ring 2 Valve 3 4 FxM Ball 3 Bracket Single Housing 4 Screw 5 OFTWHRM Replacement Cartridge 6 Pressure Relief Button IN OUT inlet outlet...

Страница 7: ......

Страница 8: ...e Such replacement parts will be delivered to the owner F O B nearest factory at no cost excluding freight and local labor charges if any Our obligation under this warranty with respect to the OneFlow...

Страница 9: ...ouche OFTWHRM ne permet pas d liminer les grains cependant d autres contaminants pr sents dans l eau d graderont graduellement l efficacit de cette cartouche Remplacez la cartouche OFTWHRM au moins un...

Страница 10: ...rbonate de calcium En raison des variations de la chimie de l eau 30 grains par gallon sont un maximum de duret recommand e en raison de probl mes esth tiques potentiels li s la formation de r sidus f...

Страница 11: ...quipement ce stade Avant de faire le raccordement l quipement cette conduite sera utilis e pour faciliter la vidange du syst me Ou un robinet de vidange dans un T sur le c t sortie du syst me OneFlow...

Страница 12: ...ture maximale 100 F 38 C Adaptateur MPT 3 4 po 19 mm n cessaire pour s adapter l entr e FPT Tuyau de 3 4 po 19 mm ou tuyau distributeur de boisson flexible renforc de 3 4 po 19 mm de diam tre int rieu...

Страница 13: ...i quip et rincez la nouvelle cartouche dans le drain ou le seau pendant deux 2 minutes ou jusqu ce que l eau soit claire S il n y a pas de robinet de rin age d tacher la conduite de l quipement pour v...

Страница 14: ...du dessin Description 1 Porte filtre avec PR 1a Joint torique 2 Robinet bille FxM de 3 4 po 19 mm 3 Support porte filtre simple 4 Vis 5 Cartouche de remplacement OFTWHRM 6 Bouton de d charge de la pr...

Страница 15: ...15...

Страница 16: ...e r v lent d fectueuse s pendant la p riode de garantie indiqu e ci dessus Ces pi ces de rechange seront livr es au propri taire F O B franco bord l usine la plus proche sans frais l exclusion des fra...

Страница 17: ...de eliminaci n de dureza granos sin embargo otros contaminantes presentes en el agua degradar n gradualmente la efectividad de este cartucho Cambie el cartucho OFTWHRM al menos una vez cada dos a os...

Страница 18: ...to c lcico Debido a las variaciones en la qu mica del agua 30 granos por gal n es el m ximo de dureza recomendado debido a posibles problemas est ticos relacionados con la formaci n de residuos de sar...

Страница 19: ...ecte la tuber a al equipo en este momento Antes de conectar al equipo esta l nea se utilizar para facilitar el lavado del sistema Como opci n se puede proporcionar una v lvula de drenaje en una T situ...

Страница 20: ...arse a la salida FPT Presi n m xima 90 psi Temperatura m xima 100 F 38 C Adaptador MPT de 3 4 necesario para adaptarse a la entrada de FPT Tubo de 3 4 o tubo de bebidas reforzado con D I de 3 4 de sum...

Страница 21: ...te de la v lvula de lavado de la carcasa del filtro si la hay y lave el cartucho nuevo al drenaje o la cubeta durante dos 2 minutos o hasta que el agua salga limpia Si no hay v lvula de lavado descone...

Страница 22: ...w OFTWH N de id de dibujo Descripci n 1 Carcasa con PR 1a Junta t rica 2 V lvula 3 4 FXm Bola 3 Soporte carcasa nica 4 Tornillo 5 Cartucho de remplazo OFTWHRM 6 Bot n de alivio de presi n IN OUT inlet...

Страница 23: ......

Страница 24: ...te Dichos remplazos se entregar n a la f brica LAB libre a bordo m s cercana al propietario sin costo alguno sin incluir los cargos de flete y mano de obra local si los hubiera Nuestra obligaci n en v...

Отзывы: