background image

9. Modular Installations

When used in modular installations, the LFTWHG2 hot valve 

assembly can be field configured to provide hydraulic isolation of 

units that need service or repair while other units remain operat-

ing. To provide hydraulic isolation from a pressurized hot water 

main, the pressure-activated seal must be rotated 180 degrees 

from the bottom port to the upper port as follows;

1.   With the valve in the closed position (handle facing forwards), 

remove handle plug, handle and stop plate;

2.   Place handle back on rotor hub and rotate 180 degrees so 

handle is facing rearward;

3.   Remove handle and re-install stop plate aligning the notch 

(marked with a X) with the nub on the body;

4.   Re-install handle (facing to the rear) and handle plug. The 

valve will now provide hydraulic isolation from a pressurized 

hot water main and be locked closed to prevent operation of 

water heater.

5.   To place heater back in commission, reverse the above pro-

cess.

Содержание LFTWHG2 Series

Страница 1: ...less water heater and apply thread sealant to the threads b Slightly loosen the union nut on the top of the cold water valve so that the union tailpiece rotates freely c Holding the cold water valve beneath the cold water inlet thread the union tailpiece onto the inlet and hand tighten Using a wrench tighten the union tailpiece Next position the cold water valve with the purge port pointing forwar...

Страница 2: ...pen when the main valve handle is parallel with the main valve body and closed when the main valve handle is perpendicu lar to the main valve body d For the purge port valves the purge port valve is open when the handle is parallel with the purge port valve body and closed when the handle is perpendicular to the purge port valve 7 Inspection and Maintenance a See tag attached to pressure relief va...

Страница 3: ...pper port as follows 1 With the valve in the closed position handle facing forwards remove handle plug handle and stop plate 2 Place handle back on rotor hub and rotate 180 degrees so handle is facing rearward 3 Remove handle and re install stop plate aligning the notch marked with a X with the nub on the body 4 Re install handle facing to the rear and handle plug The valve will now provide hydrau...

Страница 4: ...this product does not work properly other costs resulting from labor charges delays vandalism negligence fouling caused by foreign material damage from adverse water conditions chemical or any other circumstances over which the Company has no control This warranty shall be invalidated by any abuse misuse misapplication improper installation or improper maintenance or alteration of the product Some...