M200 Installation Specifications
M-200
1
1
07/07/03
C
Watts Premier
Craig Schmitt
7/8/2003
M-200 PROCESSOR SPECIFICATIONS
1) INLET WATER: MUST BE POTABLEWATER THAT IS
MICROBIOLOGICALLY SAFE.
2) CONNECTIONS:
1,2 & 3 ARE 1/2" NPT; L GRADE COPPER
WITH FLAIRED FITTINGS REQUIRED.
3) PRESSURE:
MIN. 40 PSI, MAX 90 PSI (OPTIMUM 65 PSI)
PRESSURE REGULATOR P/N 134030 REQUIRED
IF OVER 90 PSI.
4) PH RANGE:
4-7 PPM.
5) HARDNESS:
MAXIMUM 10 GRAINS OR 171 PPM.
6) TEMPRATURE:
MIN 40 DEG. F MAX 100 DEG. F
(OPTIMUM 77 DEG. F).
7) TDS:
MAXIMUM 1200 PPM OR 500mg/L NaCl
8)
First year preventitive maintenance kit included. (P/N 501020)
9) CLEARANCE:
MINIMUM 18" SERVICE CLEARANCE ON
SIDES D & C, MINIMUM 35" ON SIDE A.
10) FLOOR DRAIN REQUIREMENTS:
MIN. 1/2" DIA. WITHIN
10' OF PROCESSING UNIT.
SOURCE OF SUPPLY: PROCESSOR P/N 570200
MFG: Watts Pure Water
Phoenix, AZ USA
9.50
9.50
24.00
22.00
14.00
16.07
1.50
13.00
16.02
21.15
20.00
24.00
22.00
(1)
PERMEATE WATER CONNECTION (1/2" NPT)
(2) CONCENTRATE WATER CONNECTION (1/2" NPT)
(3) FEED WATER CONNECTION (1/2" NPT)
LEFT SIDE B
FRONT (ACCESS PANEL SIDE) A
TOP VIEW (ACCESS PANEL) D
RIGHT SIDE AIR VALVE ACCESS PANEL C
TANK NEEDS TO BE EMPTY WHEN CHARGING
TO THE REQUIRED 15 P.S.I.
BOLT HOLES FOR CEILING MOUNT (4 PLACES)
3/8" THREAD STOCK WITH WASHERS AND
LOCK NUTS REQUIRED
MANUAL BYPASS VALVE FOR RAPID STARTUP / BOILER FILL.