23
Master Programming Mode
Flow Chart - Cont’d
User Programming Mode
Flow Chart
Example:
Range: 0 - 23 Hours 59 Minutes
Example:
Start Lock Window
End Lock Window
Example:
Range: 0 - 240 M
Example:
Range: 0 - 240 M
Example:
Range: 0 - 240 M
Example:
Range: 0 - 240 M
Example:
Range: 0 - 240 M
Example:
Paddle (0.75", 1", 1.5", 2", 3")
Turbine (0.75", 1.25", 1.5")
Generic
All HC-300, HCTA-300 & HCP-300 use a 3" Paddle Meter.
Example:
Range: 0.1 to 999.9 gpm/Lpm
Example:
Off, Alarm Based, Cycle Based, Time Based,
Volume Based, Standby
Example:
Off, Alarm Based, Cycle Based, Time Based,
Volume Based, Standby
Example:
Off, Delayed, Enter Code, Time Based
User Programming Mode
1. Press and hold the Down and Up buttons simultaneously for
3 seconds to enter the User Programming mode.
2. To navigate the menu, press the Extra Cycle button to
advance to the next value. Press the Left button to retreat to
the previous value.
3. Where applicable, use the Up and Down buttons to adjust a
value as desired.
4. After progressing through all available values, the controller will
return to Normal operation.
5. To exit diagnostic mode, progress through all cycles, or press
& hold Left button at any time, or simply wait 5 minutes and
controller will automatically return to normal operation.
6 Depending on the current controller settings, certain values
may not be able to be viewed or set.
7. The controller will display local information, not system
information.
8. In the event of a regeneration occurring while displaying user
programming, the regeneration step and time remaining will
be displayed. When regeneration has been completed, the
display will return to the main screen.
Example:
Range: Off - 99 Days
Example:
Range: 0 - 23 Hours 59 Minutes
Example:
Range: 1 - 999 grains per gallon
Example:
Range: 1 - 99999 gallons