37
hour programmed following your weekly program.
This automatic control system works in the following
way:
When you start your thermostat for the first time, it will
measure the time taken by your installation to reach
the set temperature. The thermostat will re-measure
this time at each program change to compensate
external temperature change & influence. You can now
program your thermostat without the need to adjust the
temperature in advance because your thermostat does
it automatically for you.
08
Clr ALL
: Reset to Factory setting
Press and maintain
(Ok)
key during 10s to reset Set
points temperatures and user parameters in this menu
to factory default settings. User programs will also be
resetted.
* Pay attention:
Ensure you that you have all necessary elements to re-
setup your installation before to use this function.
09
Software version
VErS ___
10
End:
Exit the parameter’s menu
Press
(OK)
key to exit installation parameter menu and
38
return to normal operation.
6 Technical
characteristics
Measured temperature
precision
0.1°C
Environmental:
Operating temperature:
Shipping and storage
temperature:
0°C - 40°C
-10°C to +50°C
Setting temperature range
Comfort, Reduced
Holiday (Antifreeze)
Timer
5°C to 35°C by 0,5°C step
10°C (adjustable)
5°C to 35°C
Regulation characteristics
Proportional Band (PWM
2°C for 10min cycle) or
Hysteresis of 0.5°C
Electrical Protection
Class II - IP30
Power Supply
Operating life
2 AAA LR03 1.5V Alkaline
~2 years
Receiver Output
Maximum load
Relay 5Amps 250Vac
3A in 230Vac (Free contact)
39
Optional External sensor
10k ohms at 25°C
Software version
Displayed in the user
menu.
Norms and homologation:
Your thermostat has been
designed in conformity with the
following standards or other
normative documents:
EN 60730-1 : 2003
EN 61000-6-1 : 2002
EN 61000-6-3 : 2004
EN 61000-4-2 : 2001
Low voltage 2006/95/CE
EMC 2004/108/CE
40
7
Troubleshooting & Solution
My
BT DP-01
doesn’t start
Batteries
Problem
- Check if the protection sticker on the
batteries is removed.
- Check the batteries orientation.
- Check the capacity of the batteries
My
BT DP-01
Led, blinks in Red
Problem on
sensors
The logo blinks (ambient sensor)
- Contact your installer or seller.
The logo blinks (Floor sensor)
- Check the connection of the sensor.
- Disconnect the sensor, and check it
with an ohmmeter
(the value must be around 10kohms)
Batteries level is
too less
The logo blinks (Batteries)
- Replace the batteries.
41
My
BT DP-01
seems work correctly but the heating doesn’t
work correctly
Output
- Check the connections.
- Check the power supply of the
heating element.
- Contact your installer.
My
BT DP-01
seems work correctly but the temperature in
the room was never in accordance with the program.
Program
- Check the Clock.
-The difference between Comfort &
Reduced temperature is too high?
- The step in the program is too
short?
- Contact your installer, to check &
adjust the regulation parameters
with your heating system.
42