13
Replacement Carbon Block Filter Cartridge:
Model Number BB-C100
Ordering Code 7100980
Replace filter when BB-M101 Volumetric
Flow Monitor sends email or text message
alerts indicating that 100% of filter capacity
has been consumed. If BB-M101 is not con-
nected to Wi-Fi, filter change notification will
appear on the display screen only.
Step 1 -
Turn off inlet and outlet isolation valves and open
an inside faucet, both hot and cold side, to relieve any pressure
within the plumbing system.
Step 2 -
Press red pressure relief button on top of filter
housing lid until water stops flowing from button and the
pressure gauge on top of filter housing lid shows “0” PSI.
Step 3 -
Open drain valve and completely drain water from filter
housing. Drain line must route to a drain receptacle (i.e., floor
drain or drain pipe) where drain water will not cause personal
injury or property damage.
Step 4 -
Loosen eye bolt nuts on top of filter housing and
remove lid.
Step 5 -
To remove filter cartridge from filter housing, grip the
handle on top of the filter cartridge, turn counterclockwise then
lift filter cartridge up and out of filter housing.
Step 6 -
Inspect inside of filter housing for debris and clean
as necessary.
Step 7 -
Remove new filter cartridge from packaging bag.
Grip the handle on top of the filter cartridge and insert filter car-
tridge into filter housing. Lower filter cartridge into filter housing,
pushing down while rotating clockwise until filter cartridge comes
to a positive stop.
Step 8 -
Ensure lid O-ring is properly seated on top of filter
housing and reinstall filter housing lid (replace O-ring if damaged-
Ordering Code 68100619). Swing the eyebolts into the upward
position, and tighten nuts hand tight in an opposing style pattern.
Continue tightening nuts in this opposing pattern until all are fully
hand tight. (See Preparing System for Installation Step 6)
Step 9 -
Perform a New Filter Reset on the BB-M101
Volumetric Flow Monitor:
• From the System Home / Dashboard screen touch the lower
right
Menu
icon.
• Touch
New Filter Reset
• Touch
Reset Now
• Confirmation screen will appear:
Are you sure you want you
reset now?
Touch
Yes
• After confirming reset, the screen will go back the Home /
Dashboard screen and resume normal operation.
Follow System Start Up Procedure steps 3-7 to prepare the
system for operation.
The system is now ready to use.
Filter Cartridge Replacement Procedure