background image

INSTALLATION QUICK LOOK          

                                                                

Please follow 4 color tubing diagram to complete installation 

CAUTION: When cutting supplied tubes, predeter-

mine the length by measuring the distance between 

the components to be connected. 

No tools are needed to connect 4 colored tubes.

 

HOW TO MAKE A CONNECTION 

1. CUT THE TUBE SQUARE 

Cut the tube square. It is essential that the outside diameter 

be free from score marks and that burrs and sharp edges be 

removed before inserting into fitting. For soft thin walled plastic 

tubing we recommend the use of a tube insert. 

 

2. INSERT TUBE 

Fitting grips before it seals. Ensure tube is pushed into the tube 

stop. 

 

 

3. PUSH UP TO TUBE STOP 

Push the tube into the fitting, to the tube stop. The collet 

(gripper) has stainless steel teeth which hold the tube firmly in 

position while the o-ring provides a permanent leak proof seal. 

 

4. PULL TO CHECK SECURE 

Pull on the tube to check that it is secure. It is a good practice to 

test the system prior to leaving site and/or before use. 

 

Disconnecting

 

PUSH COLLET AND REMOVE TUBE 

To disconnect, ensure the system is depressurized before 

removing the tube. Push in collet squarely against face of fitting. 

With the collet held in this position, the tube can be removed. 
The fitting can then be re-used. 

Installation needs to comply with State and local plumbing regulations.

Connections

Item No.

Color of Tubing

Description

A

RO Faucet

FU-WDF-905-CP

Blue

Pure water to the Faucet

B

Feed Water Valve

F560080 / F560070

Green

Feed Water to RO System

C

Tank Ball Valve

PSV501222W

Yellow

Pure Water to Storage Tank

D

Drain Connector

SC500B14/38

Red

Discharge Water to Drain

7

Содержание 315

Страница 1: ...rence WARNING Do not use with water that is microbiologically unsafe or of unknown quality without adequate disinfection before or after the system If you are unsure about installing your WATTS water filter contact a WATTS representative or consult a professional plumber Test the water periodically to verify that the system is performing satisfactorily Discard small parts remaining after the insta...

Страница 2: ...ve drain saddle clamp 1 4 3 8 feed water valve faucet assembly 4 Manual Variable speed drill 1 8 and 1 4 drill bits 7 16 drill bit 1 2 and 9 16 open end wrenches or adjustable Phillips screwdriver Utility knife RECOMMENDED TOOLS LIST This reverse osmosis system contains a replaceable component critical to the efficiency of the system Replacement of the reverse osmosis component should be with one ...

Страница 3: ...er 5 micron 10 Auto shut off valve Operating pressure 40 100 PSI Operating temperature 40 100 F Please contact your local dealer at REPLACEMENT PARTS WATTS ITEM DESCRIPTIONS SERVICE LIFE F109009 Carbon block filter 5 micron 10 6 12 months W 1812 50 TFC membrane 50GPD 60PSI 24 36 months F109009 Carbon block filter 5 micron 10 6 12 months 3 ...

Страница 4: ...Operating pressure 40 100 PSI Operating temperature 40 100 F Please contact your local dealer at REPLACEMENT PARTS WATTS ITEM DESCRIPTIONS SERVICE LIFE IF SP 1005 Sediment filter 5 micron 10 6 12 months F109009 Carbon block filter 5 micron 10 6 12 months W 1812 50 TFC membrane 50GPD 60 PSI 24 36 months W560033 Inline carbon filter 12 18 months 4th stage Inline carbon filter 4 ...

Страница 5: ...temperature 40 100 F Please contact your local dealer at REPLACEMENT PARTS WATTS ITEM DESCRIPTIONS SERVICE LIFE IF SP 1005 Sediment filter 5 micron 10 6 12 months F109009 Carbon block filter 5 micron 10 6 12 months F109009 Carbon block filter 5 micron 10 6 12 months W 1812 50 TFC membrane 50GPD 60PSI 24 36 months W560033 Inline carbon filter 12 18 months 4th stage TFC membrane 50GPD 60 PSI 5th sta...

Страница 6: ...temperature 40 100 F Please contact your local dealer at REPLACEMENT PARTS WATTS ITEM DESCRIPTIONS SERVICE LIFE IF SP 1005 Sediment filter 5 micron 10 6 12 months F109009 Carbon block filter 5 micron 10 6 12 months F109009 Carbon block filter 5 micron 10 6 12 months W 1812 50 TFC membrane 50GPD 60PSI 24 36 months W560033 Inline carbon filter 12 18 months 4th stage TFC membrane 50GPD 60 PSI 5th sta...

Страница 7: ...ollet gripper has stainless steel teeth which hold the tube firmly in position while the o ring provides a permanent leak proof seal 4 PULL TO CHECK SECURE Pull on the tube to check that it is secure It is a good practice to test the system prior to leaving site and or before use Disconnecting PUSH COLLET AND REMOVE TUBE To disconnect ensure the system is depressurized before removing the tube Pus...

Страница 8: ...uid soap to keep the hole saw cool during cutting 2 Drill a pilot hole Use a 1 2 Hole Punch and an adjustable wrench to punch the hole in the sink Change to the 1 Hole Punch to enlarge the hole 5 The faucet can now be installed If mounting faucet to a Stainless Steel Sink you will need a 1 2 1 Hole Punch The faucet opening should be centered between the back splash and the edge of the sink ideally...

Страница 9: ...ter is a 3 8 quick connect elbow fitting Attach the open end of the 3 8 blue tubing from the RO faucet to the 3 8 quick connect elbow on the polishing filter With Non Air Gap faucets this will be the only tube connected to the RO faucet Air Gap Faucet Follow the drinking feed tube connection instruc tions above Connect the 1 4 drain tube from the RO module up to the 1 4 fitting on the RO faucet Th...

Страница 10: ...e pieces of the drain saddle Caution Do not over tighten the screws It may crack the drain saddle If you have a garbage disposal do not install the drain saddle near it Installation of the drain saddle must be either above the garbage disposal or if a second sink drain is available install it above the cross bar on the second drain Installation of the drain saddle near a garbage disposal may cause...

Страница 11: ...ll valve off TOPVIEW OFTANK BALLVALVE PPSV501222W OFF POSITION ON POSITION Fig 5 STEP 4 MOUNTING THE DRAIN CLAMP The drain clamp SC500B14 38 will fit most standard drain pipe 1 4 It should be installed above the trap and on the vertical tailpiece See Fig 6 1 Position the drain saddle in desired location mark spot through thread outlet remove saddle 2 Drill 1 4 6 3mm hole into the drain pipe above ...

Страница 12: ...tart up and periodic maintenance Your RO tank must be allowed to fill up fully in order for the ice maker system to work properly After the Tank has filled open the RO Faucet to flush the tank completely You will know that the tank is empty when the flow rate from the RO faucet is down to a trickle Repeat this step two more times The fourth tank can be used for drinking This flushing process shoul...

Страница 13: ...of unscented 5 25 sodium hypochlorite liquid household bleach into each of the clean housings and replace housings on the RO system 8 Disconnect RO storage tank from the system 9 RO storage tank cleaning procedure Tank sanitizer feeder or small filter housing with fittings and tubing Disinfectant solution Pressure gauge and air pump a The tank should be empty Check the air pre charge pressure with...

Страница 14: ...er at the source water supply with RO faucet open 13 When the flow of water has stopped at the RO faucet remove the filter housing sumps and membrane housing from the RO system Replace the filters and membrane according to the service life 14 Replace the housings on the RO system Open the source water valve and allow the water to flow from the faucet Because some of the disinfectant may still be i...

Страница 15: ...rocedures a Shut off the water supply b Turn off the tank ball valve by turning it 90 degrees c Open RO faucet to the continuous flow position to relieve pressure d Slide in the housing wrench Use one hand to hold the system and the other hand to turn the wrench clockwise to open the housing e After opening the housing remove the used filter and put the new filter into the housing Make sure the o ...

Страница 16: ...nic Facts section of the Performance Data Sheet for further information Avg In Avg Eff Reduction pH Pressure Max Eff Inf challenge Max Allowable mg L mg L mg L concentration concentration mg L mg L Arsenic Pentavalent 0 3 0 001 99 6 50psi 0 004 0 30 10 0 010 mg L Barium Reduction 10 0 12 98 8 7 24 50psi 0 23 10 0 10 2 0 Cadmium Reduction 0 03 0 0003 98 8 7 49 50psi 0 0008 0 03 10 0005 Chromium Hex...

Страница 17: ...IFE IF SP 1005 Sediment filter 5 micron 10 6 12 months F109009 Carbon block filter 5 micron 10 6 12 months W 1812 50 TFC membrane 50GPD 60 PSI 24 36 months W560033 Inline carbon filter 12 18 months WATTS ITEM DESCRIPTIONS SERVICE LIFE IF SP 1005 Sediment filter 5 micron 10 6 12 months F109009 Carbon block filter 5 micron 10 6 12 months F109009 Carbon block filter 5 micron 10 6 12 months W 1812 50 ...

Страница 18: ...als such as ozone and potassium permanganate will also change trivalent arsenic to pentavalent arsenic A combined chlorine residual also called chloramine where it does convert trivalent arsenic to pentavalent arsenic may not convert all the trivalent arsenic in to pentavalent arsenic If you get your water from a public water utility contact the utility to find out if free chlorine or combined chl...

Страница 19: ... in storage tank is low Normally it takes 2 3 hours to fill tank Low water pressure and or temperatures can reduce production rate Add pressure to storage tank The pressure should be 8 10 psi when the tank is empty Slow production Low water pressure Crimps in tubing Clogged pre filters Fouled membrane Add a booster pump Make sure tubing is straight Replace pre filters Replace membrane Water taste ...

Страница 20: ...ppm 4 The pH of the water must not be lower than 2 or higher than 11 5 The incoming water pressure must be between 40 and 100 pounds per square inch 6 Incoming water to the RO cannot exceed 105 degrees F 40 degrees C 7 Incoming TDS Total Dissolved Solids not to exceed 1000 ppm 8 Do not use with water that is microbiologically unsafe or of unknown quality without adequate disinfection before or aft...

Страница 21: ...tion please visit www watts com or the published literature that comes with your product Any remedies stated in such warranties are exclusive and are the only remedies for breach of warranty EXCEPT FOR THE APPLICABLE PRODUCT WARRANTY IF ANY WATTS MAKES NO OTHER WARRANTIES EXPRESS OR IMPLIED TO THE FULLEST EXTENT PERMITTED BY APPLICABLE LAW WATTS HEREBY SPECIFICALLY DISCLAIMS ALL OTHER WARRANTIES E...

Отзывы: