Manual #199355
Rev 08/14/15
© 2015 Watts Premier
8716 West Ludlow Dr, Ste 1, Peoria, AZ 85381 • Tel. (800) 752-5582 • www.wattspremier.com
A Watts Water Technologies Company
THIRD FILTER BOWL
ON FIVE-STAGE ONLY
TO
KITCHEN
SINK
PUMP
SELENOID
FEED (GREEN)
WIRE HARNESS
SEDIMENT
PRE-FILTER
CARBON
PRE-FILTER
CARBON
PRE-FILTER
DRAIN
SADDLE
PLUG
ADAPT-A-VALVE
HOT-WATER
SHUT-OFF
TO
KITCHEN
SINK
COLD-WATER
SHUT-OFF
RO MEMBRANE
POST-CARBON
FILTER
STORAGE TANK
TANK
SHUT-OFF
VALVE
CHECK
VALVE
TRANSFORMER
TANK
(BLUE)
PRESSURE
SWITCH
ADAPT-A-VALVE
BRINE
(RED)
BRINE (BLACK)
1
5
3
4
2
Five-Stage Standard Unit Connection Steps
Step 1 -
Remove the existing Automatic Shut-off Valve
Step 2 -
Install the Booster Pump and Solenoid between the third stage filter canister and the cap of the reverse osmosis membrane (if
needed, use provided green tube)
Step 3 -
Connect the red flow restrictor tube into the brine elbow
Step 4 -
Connect the open end of the black hose into the adapt-a-valve connected to the hot water shut-off
Step 5 -
Splice the pressure switch on the line leading to the tank