Page 22
RECOMMENDED REPLACEMENT PARTS AND CHANGE INTERVALS:
Note: Depending on incoming feed water conditions replacement time frame may vary.
Description
Change time Frame
Sediment Pre-filter: #5m-10
6 Months
Carbon Pre-filter: #GAC-410-56/#5MCB
6 Months
Final Carbon filter #1M-6/#1M-10
12 Months
R.O. Membrane:
#TFM-24
2 to 5 years
This system has been tested according to NSF/ANSI 58 for reduction of the substances listed below. The concentration of the indicated substances
in water enter�
ed in
NSF/ANSI 58. This system has been tested for the treatment of water containing pentavalent arsenic (also known as As (V), As (+5), or arsenate)
at concentrations of 0.30 mg/L or less. This system reduces pentavalent arsenic, but may not remove other forms of arsenic. This system is to
be used on water supplies containing a detectable free chlorine residual at the system inlet or on water supplies that have been demonstrated to
contain only pentavalent arsenic. Treatment with chloramine (combined chlorine) is not sufficient to ensure complete conversion of trivalent arsenic
to pentavalent arsenic. Please see the Arsenic Facts section of the Performance Data Sheet for further information.
Avg. In.
Avg. Eff.
% Reduction pH
Pressure Max Eff. Inf. challenge
Max Allowable
concentration
concentration
mg/L
mg/L
Arsenic (Pentavalent) 334.615 ug/L 5.0385 ug/L
98.4%
50psi
19 ug/L
0.30±10%
0.010 mg/L
Barium Reduction
10.2 mg/L
0.207 mg/L
97.9%
7.24
50psi
0.3 mg/L
10.0±10%
2.0
Cadmium Reduction
0.036 mg/L 0.0005 mg/L
98.6%
7.49
50psi
0.0007
0.03±10%
0005
Chromium (Hexavalent) 0.15 mg/L
0.013 mg/L
91.3%
7.24
50psi
0.03
0.3±10%
0.1
Chromium (Trivalent)
0.17 mg/L
.01 mg/L
94.1%
7.24
50psi
0.01
0.3±10%
0.1
Copper Reduction
3.1 mg/L
0.03 mg/L
99.0%
7.64
50psi
0.04
3.0±10%
1.3
Cysts
222,077#/ml
10 #/ml
99.99%
58 minimum 50,000/mL
Fluoride Reduction
8.0 mg/L
0.5 mg/L
93.9%
7.49
50psi
0.7
8.0±10%
1.5
Lead Reduction
0.15 mg/L
0.002 mg/L
98.6%
7.49
50psi
0.003
0.15±10%
0.010
Perchlorate
0.10 mg/L
0.003 mg/L
96.5%
7.39
50 psi
0.005
0.10±10%
0.006
Radium 226/228
25pCi/L
5pCi/L
80.0%
7.24
50psi
5pCi/L
25pCiL±10%
5pCiL
Selenium
0.10
0.008
92.0%
50psi
0.011
0.10±10%
0.05
TDS
765
23 mg/L
96.8%
7.84
50 psi
33 mg/L
750±40mg/L
187
Turbidity
10.2 mg/L
0.26 mg/L
97.5%
0.83
11±1 NTU
0.5 NTU
Depending on water chemistry, water temperature, and water pressure Watts Premier’s R.O. Systems production and performance will vary.
Efficiency rating means the percentage of the influent water to the system that is available to the user as reverse osmosis treated water under operating
conditions that approximate typical daily usage.
Recovery rating means the percentage of the influent water to the membrane portion of the system that is
available to the�
There is
an average of 4 gallons of reject water for every 1 gallon of product water produced.
REFER TO OWNER’S INSTALLATION/SERVICE MANUAL FOR FURTHER MAINTENANCE REQUIREMENTS AND WARRANTY INFORMATION.
�
GENERAL USE CONDITIONS:
1. S�
. DO NOT use
with wate�
ed for cyst
reduction may be used on disinfected water that may contain filterable cysts.
2. Operating Temperature:
Maximum: 100°F (40.5°C)
Minimum: 40° (4.4°)
3. Operating Water Pressure:
Maximum: 85 psi (7.0kg/cm2)
Minimum: 40 psi (2.8kg/cm2)
4. pH
2 to 11
5. No iron present in incoming feed water supply.
6. Hardness of more than 10 grains per gallon (170 ppm) may reduce TFM membrane life expectancy.
7. Recommend TDS (Total Dissolved Solids) not to exceed 1800 ppm.
Watts Premier Inc.
1725 W. Williams Drive C-20
Phoenix, AZ 85027 USA
(623) 931-1977 [email protected]
Model No.
Avg.
Avg.
Avg. TDS DPR
Influent
Effluent
IN /EFF
RECOVERY
GALLONS
EFFICIENCY
TDS
TDS
REDUCTION
765 mg/l
23mg/l
96.8%
15.5%
9.06gpd
8.35%
Performance Data Sheet