Watts Industries AERCO Innovation 24429 Скачать руководство пользователя страница 5

  

Innovation Anode Retrofit Kit Instructions  

 

Kit # 24429

 

TID-0128_0B 

 

 

05/21/2015 

AERCO International, Inc. 

 100 Oritani Dr. 

  Blauvelt, New York 10913 

 Phone: 800-526-0288  

  

Page 5 of 6

 

Anode Assembly Installation

 – Continued

 

7. 

Fully tighten the 5/16-24 hex nut on the positioning screw to lock it in place. The mounting 
bracket is now firmly attached to the lifting hook, ensuring  that the anode blocks are 
electrically connected to the unit. 

8. 

Position the four (4) ‘O’ rings (P/N 

88019

) in the circular recesses around the threaded 

holes in the anode blocks (P/N 

44174

). The ‘O’ rings keep water from entering the 

threaded holes, preventing them from corroding, which would shorten the anode’s life. 

9. 

Fasten one anode block to the mounting bracket with two (2) 1/4–20 hex head seal bolts 
(P/N 

54108

) and fully tighten them. Note that these are specialized bolts with built-in ‘O’ 

rings –

 

DO NOT

 

substitute off-the-shelf bolts of the same size

DO NOT over-tighten 

these bolts.

 

10. 

Repeat the previous step to attach the second anode block to the mounting bracket.  

11. 

Remove any hardware or debris that may have fallen on the cardboard shield installed in 
step 1 and then remove the shield from the chamber. 

 

6.

 

Reassembling the Heat Exchanger 

Reassembling the Heat Exchanger

 

1. 

Place the new head gasket (P/N 

18532

) on top of the heat exchanger shell flange. 

2. 

Place the new  head release gasket (P/N 

18556

),  upper head liner  and  upper head on, 

aligning them with the 5/8-11 X 3-3/4” studs in the shell flange.   

3. 

Replace the nuts and washers on the 5/8-11 X 3-3/4” studs.  

4. 

Cross tighten the nuts to approximately 75 ft.-lb. torque to obtain a uniform seating, then 
progressively tighten the nuts to 200 ft/lbs. minimum. 

 

7.

 

Returning the Unit to Service 

Returning the Unit to Service

 

5. 

Close the drain valve. 

6. 

Reopen the unit’s water inlet, outlet, and recirculation shut-off valves.  

7. 

Reinstall the unit’s front, top and side panels. 

8. 

Turn on the supply gas upstream to the unit. 

9. 

Reconnect AC power to the unit. 

10. 

Set the ON/OFF switch on the control panel to the 

ON

 position.  

 

--- END --- 

 

 