WB-OVRC-UPS-1100/1500/2000 Owner’s Manual

SPECIFICATIONS

MODEL

WB-IP-UPS-1100-1

WB-IP-UPS-1500-1

WB-IP-UPS-2000-1

CAPACITY

1100VA/990W

1500VA/1350W

1900VA/1710W @120V Output

 

1740VA/1566W @110V Output

INPUT
Voltage

110/120V AC

Acceptable Voltage Range

81-145V AC

Frequency Range

60/50 Hz (Auto sensing)

Power Outlet

NEMA 5-15

NEMA 5-20

Power Inlet

IEC C14

IEC C20   

Surge Protection Modes

L-N, L-G, N-G

Joule Rating (minimum)

1080J

OUTPUT
Output Voltage

110/120V AC

Outlet Quantity

(1) NEMA 5-15

(1) NEMA 5-15

(1) NEMA 5-20

Connections

USB, RS-232 (standard DB-9)

Voltage Regulation (Batt. Mode)

± 1.5% (before battery alarm)

Frequency Range (Batt. Mode)

50 Hz or 60 Hz ± 1 Hz

Current Crest Ratio

3:1

Harmonic Distortion

2% max @ 100% linear load, 5% max @ 100% non-linear load (before low battery alarm)

Transfer Time

Typical 2-6 ms, 10 ms max.

Waveform (Batt. Mode)

Pure sinewave

EFFICIENCY
AC Mode

95%

96%

Buck & Boost Mode

93%

94%

Battery Mode

88%

90%

BATTERY
Type & Number

12 V/9AH x 2

12 V/9AH x 4

Terminal Type

F2

F2

Typical Recharge Time

4 hours recover to 90% capacity

Charging Current (Max.)

1.5A

1.5A

1.5A

Charging Voltage

27.4V DC ± 1%

54.8 V DC ± 1%

PROTECTION
Joule Ratings

Line-neutral: 158J*2; Line-ground: 264J*2; Neutral-ground: 264J*2; Total joule rating: 1372J

INDICATORS
LCD Display

AC Mode, Battery Mode, Load Level, Battery Level, Input Voltage, Output Voltage, Overload, Fault, and Low Battery

ALARM
Battery Mode

Sounds every 10 seconds

Low Battery

Sounds every 2 seconds

Overload

Sounds every 1 second

Fault

Continuously sounding

PHYSICAL

Dimensions (WxHxD)

437.90 mm(17.24") x 87.88 mm (3.46") 

x 409.96 mm (16.14")

437.90 mm(17.24”) x 87.88 mm (3.46”) x 510.03 mm(20.08)”

Rack Mount

2 RU

ENVIRONMENT
Maximum Operating Temperature

40 °C(104 °F)

Humidity

0-90 % RH @ 0- 40 °C (Non-condensing)

Noise Level

Less than 45dB

MANAGEMENT
Smart RS-232/USB

Supports Windows 2000/2003/XP/Vista/2008, Windows 7/8/10, Linux, Unix, and MAC

Optional SNMP

Power management from SNMP manager and web browser

Содержание WB-OVRC-UPS-1100-1

Страница 1: ...eased in Buck mode Battery Backup for WattBox IP Devices Battery backup for powering critical equipment connected to a WattBox IP device during power outages and fluctuations Batteries can be serviced...

Страница 2: ...REAR PANEL SEE DIAGRAMS ON OPPOSITE PAGE 1 Circuit Breaker Resetting circuit breaker that trips out the unit when over amperage conditions occur 2 EPO Emergency Power Off Two pin terminal for turning...

Страница 3: ...WB OVRC UPS 1100 1500 2000 Owner s Manual pg 3 WB OVRC UPS 1100 1 REAR PANEL 8 1 2 3 4 5 6 7 WB OVRC UPS 1500 1 REAR PANEL 8 1 2 3 4 5 6 7 WB OVRC UPS 2000 1 REAR PANEL 8 1 2 3 4 5 6 7...

Страница 4: ...e rack ears to the UPS Mount the UPS in the rack with the rear of the unit resting on the back brackets POWERING THE UPS The power outlet for the UPS should be on a dedicated circuit for the best perf...

Страница 5: ...s By default a metal jumper is placed between the contacts of the EPO connector Remove the jumper and wire a normally closed switch to the connector to use an installed EPO switch EPO Reset To restore...

Страница 6: ...uttons ON MUTE SELECT OFF ENTER Button Function Instructions ON MUTE Power ON Press and hold the ON MUTE button for two seconds until the UPS beeps and ON is displayed on the LCD display The critical...

Страница 7: ...n Indicates the connected load level equipment connected to outlets in 25 increments Indicates connected device overload Indicates a short circuit in the connected load Operating Status Indicates that...

Страница 8: ...how long the programmable outlets remain on Default DIS Disable the programmable outlet function Using this setting all UPS outlets will remain on battery mode until the battery is depleted 03 Progra...

Страница 9: ...e high loss point The UPS uses the internal auto voltage regulator to step the input power down to the specified output range Boost Mode AC Normal Boost mode is used when the input voltage is lower th...

Страница 10: ...it back in 3 If issue persists contact WattBox Technical Support 28 Battery voltage too low 1 Ensure batteries are securely connected 2 Remove UPS power cord then plug it back in 3 If issue persists...

Страница 11: ...igh load connected to UPS outlets Check the LCD panel for UPS status Have an electrician check the power connection and quality of power The UPS is emitting an audible alarm UPS operating mode issue S...

Страница 12: ...quipped with internal batteries and only the service person can replace the batteries BATTERY ACCESS Step 1 Step 2 Step 3 Remove the front panel cover Disconnect the battery wires Remove the four batt...

Страница 13: ...e the new battery packs in the tray as shown above Place the cover back on the battery tray and reassemble the UPS WB IP UPS 1500 1 WB IP UPS 2000 1 FOUR BATTERY TRAY CONNECTION Step 1 Step 2 Step 3 R...

Страница 14: ...Mode 95 96 Buck Boost Mode 93 94 Battery Mode 88 90 BATTERY Type Number 12 V 9AH x 2 12 V 9AH x 4 Terminal Type F2 F2 Typical Recharge Time 4 hours recover to 90 capacity Charging Current Max 1 5A 1 5...

Страница 15: ...connections including terminal torque shall be provided Replacement of Batteries Located in a Service Access Area A Servicing of batteries should be performed or supervised by personnel knowledgeable...

Страница 16: ...or Connected Equipment Protection Policy Valid only in the United States and Canada It is the policy of WattBox that it will in its sole discretion replace pay to replace at fair market value or pay t...

Страница 17: ...out of reprogramming or loss of programming and or data shipping charges or fees service calls loss or damage occasioned by fire theft flood wind accident abuse or misuse and products subject to manu...

Страница 18: ......

Страница 19: ...200427 1016...

Отзывы: