USING TONIC POWER AND DATA 

Tonic arranges users into a simple or fully electric linear dual-sided bench table format that supports power outlets, 

data channel and many functional elements. The Tonic Bench Table unit features a modular power distribution 8-wire, 

four circuit manufactured wiring harness system. Tonic modular power distribution is based on a power raceway 

furnishing consisting of a power raceway, power blocks, preconfigured outlets, jumper cables between power blocks, 

and power feed for hardwire connection to building power supply. Each powered table segment (starter, adder and 

ender) consists of one power raceway. They are rigidly mounted atop and between desktop support rails which allow 

access from above and thru center infill surfaces. Communication and data cabling can be routed in a raceway to 

support a technology rich environment. They are facilitated with knockouts located on the power raceway. Cable slats 

are suspended in the channel underneath the power raceway furnishing.

The installed Power and Data Raceway 

creates a trough for excess cords and power 

adapters.  The underside of the Raceway is 

reserved for routing data cables.

Users — direct access to power and data receptacles 

including a trough to store excess cords and power bricks. 

Facilities/IT — ports for power cords and 

capacity for 50+ data cables.

TNC USER GUIDE  |  3

Содержание Tonic Bench

Страница 1: ...USER GUIDE Tonic Bench...

Страница 2: ...routing extension cords 11 The combined length of a Tonic furnishing configured with a power raceway furnishing shall not exceed 30 feet 9 1 m or 12 segments of 2 duplexes per user 6 segments of 4 dup...

Страница 3: ...kes the affected area using a stiff nylon bristle brush Do not scrub so as to scratch the surface finish Avoid cleaners with ammonia Marker Board Laminate Wilsonart Marker Board Laminate can be cleane...

Страница 4: ...building power supply Each powered table segment starter adder and ender consists of one power raceway They are rigidly mounted atop and between desktop support rails which allow access from above an...

Страница 5: ...h one neutral 10 gauge and one ground Single Circuit One 15 or 20 amp circuit 3 wire with one hot one neutral one ground all 12 gauge conductors The 20 amp system requires a single circuit power sourc...

Страница 6: ...26246 Twelve Trees Lane NW Poulsbo Washington 98370 800 426 1202 watsonfurniture com info watsonfg com TNC USER GUIDE 5...

Страница 7: ...CIR 3 DUPLEX CIR 3 DUPLEX WARNING RISK OF FIRE OR ELECTRIC SHOCK THIS OFFICE FURNISHING SYSTEM MAY BE CONNECTED TO MORE THAN ONE SOURCE OF SUPPLY ALL SOURCES MUST BE DISCONNECTED PRIOR TO ANY SERVICIN...

Страница 8: ...26246 Twelve Trees Lane NW Poulsbo Washington 98370 800 426 1202 watsonfurniture com info watsonfg com SAVE THESE INSTRUCTIONS TNC USER GUIDE 7...

Отзывы: