5.5.2
Physical specification
5.5.2.1 Environmental and operating conditions
Ambient temperature range
4 °C to 45 °C (39.2 °F to 113 °F)
Humidity (non-condensing)
80 % up to 31 °C (88 °F), decreasing linearly to 50 % at 40 °C
(104 °F)
Maximum altitude
2,000 m, (6,560 ft)
Pollution degree of the intended
environment
2
Noise
<70 dB(A) at 1 m
Maximum fluid temperature
SEBS pumpheads: 40 °C (104 °F)
Santoprene pumpheads: 45 °C (113 °F)
PU pumpheads: 45 °C (113°F)
Environment
Indoor and limited outdoor
Ingress protection
IP66, NEMA4X, NEMA 250
NOTE9
Chemical compatibility is dependent on temperature. A procedure for checking chemical
compatibility is provided in
"19 Chemical compatibility" on page 202
NOTE10
Under certain conditions the pump is suitable for limited outdoor use. Contact your
Watson-Marlow representative for advice.
NOTE11
Protection of drive to NEMA 250 with the HMI cover (optional accessory) installed