30 520R, 520R2 and 520RE
maintenance
As part of regular cleaning and maintenance (and at least every three months),
lubricate the pivot points, the follower rollers and the tube guide rollers with
Ultra Lube (PA 1240), which is a non-toxic perfluoroether-based grease.
The stainless steel pumping rollers run on externally-sealed bearings and are
lubricated for life.
Check that the pumphead track, rotor, rollers and spring-loaded tube clamps (if
fitted) are clean and operating properly.
If fluid is spilled inside the pumphead it should be cleaned as soon as possible,
as reducing exposure time to contamination will prolong pumphead service life.
To clean the pumphead, remove the rotor as described under
Rotor removal
,
above. Flush the pumphead out with water and mild detergent, or suitable
cleaning agent. Clean the rotor and rollers in the same way. If specific cleaning
agents are required to clean the spillage, consult the general guide to cleaning
with solvents below or Watson-Marlow after-sales office before proceeding, in
order to confirm chemical compatibility.
Note:
the pumphead guard, rotor cap
and clutch boot should be removed in advance of some cleaning regimes. See
the table below. These components are available as spares if damaged.
Replace the rotor as described under
Rotor replacement
, above.
Always isolate the pump from the mains power supply
before opening the guard or performing any positioning,
removal or maintenance activity.