![Watson Marlow Pumps 521CC Скачать руководство пользователя страница 30](http://html1.mh-extra.com/html/watson-marlow-pumps/521cc/521cc_manual_3760922030.webp)
15 520RC, 520R2C and 520REC rotor settings
520RC, 520R2C and 520REC pumpheads are factory-set to give optimum tube life with
Watson-Marlow tubing. Radial roller positions should not be adjusted in any circumstances
as this will adversely affect pumphead performance and invalidate warranty. Tamper-proof
rotor arm occlusion setting screws are fitted to warn operators from occlusion adjustment.
Tubing with a wall thickness other than 1.6mm or 2.4mm can be used only with a
pumphead set up for that purpose during manufacture. Contact Watson-Marlow technical
support.
Note
: 520RC, 520R2C, and 520REC pumpheads can not be adapted to use tube with walls
thicker than 2.4mm.
Page 30 of 47
Watson-Marlow Bredel E-Manuals
14/12/2009
file://M:\staging\pdfs-global\m-521-cc-gb-03.htm