background image

6

Roller adjustment

The 501RL has a factory set gap of 2.6mm between the rollers and the track and is suitable for tubing having wall thicknesses of

between 1.6 and 2.0mm. Adjustment of the gap will be required if tubing having a wall thickness of less than 1.6mm is required.

There is an adjusting screw on each of the two roller arms, and each of these screws will require adjustment. The correct gap is

twice the wall thickness less twenty percent. Correct adjustment is important: over occlusion will reduce tube life; under

occlusion will reduce pumping efficiency.
To change the gap setting, turn each adjusting screw clockwise to increase the gap, or anticlockwise to decrease the gap. A full

turn changes the gap by 0.8mm.To restore the original settings of 2.6mm, turn the adjusting screws until both rollers are just

touching the track, then tighten each screw by three and a quarter turns. The 501RL2 has a factory set gap of 3.8mm between

the wall and the track and is suitable for tubing having wall thickness of between 2.1 and 2.5mm.
Check moving parts of the rotor from time to time for freedom of movement. Lubricate pivot points and rollers occasionally with

Teflon lubricating oil.
Specific drive performance details such as loaded drive speed variation against mains supply voltage fluctuation and drive

stability from a cold start to normal operating temperature are available on request. For further information please contact

Watson-Marlow Technical Support Centre.

Pumphead spares

Number

Spare

Description

1

MN 1200M

Lockable guard

2

FN 4502

Lock

3

FN 2341

Hinge screw

4

MN 0266M

Hinge grey

5

MNA0623A

Tube clamp assembly

6

FN 2332

Screw

7

MN 0011T

Main roller

8

MNA0143A

501RL Rotor Assembly

9

SG0001/SG0002

Springs standard/hard

10

MN 0012T

Follower roller

XX 0095

Teflon lubricant

Содержание 504S

Страница 1: ...504S 504s gb 03 pdf...

Страница 2: ...ord with the terms of this warranty shall not be binding upon Watson Marlow Limited unless expressly approved in writing by a Director or Manager of Watson Marlow Limited Information for returning pum...

Страница 3: ...should be run only while its feet are standing on a horizontal surface The pump should be positioned to allow a free flow of air around it Remove the small transparent plate on the rear panel to gain...

Страница 4: ...rs at maximum speed If the pump requires cleaning use a mild solution of detergent in water after removing the pumphead Do not use strong solvents For gearbox rebuilds use 15ml of the recommended lubr...

Страница 5: ...out the rotor crank handle until it locks into position Select the length of tubing required noting that approximately 240mm is required for the track systems Fit one end of the tubing into one of th...

Страница 6: ...oth rollers are just touching the track then tighten each screw by three and a quarter turns The 501RL2 has a factory set gap of 3 8mm between the wall and the track and is suitable for tubing having...

Страница 7: ...488S MN 0488S Front rear panel gasket 7 MN 0487S MN 0487S Top bottom case gasket 8 BM 0014 BM 0012 Motor brush 9 MNA0388A Geared motor 220rpm 9 MNA0396A Geared motor 55rpm 9 MNA0459A Geared motor 170r...

Страница 8: ...8 Outline dimensions...

Страница 9: ...9 6 1 16 1 8 3 16 1 4 5 16 3 8 55 40 125 230 385 495 685 220 155 500 925 1540 1980 2750 505BA ml min Flow rates mm 0 13 0 005 0 19 0 007 0 25 0 01 0 38 0 015 0 50 0 02 0 63 0 025 0 76 0 03 55 0 027 0...

Страница 10: ...2 0 112 13 14 16 25 17 18 112 13 14 16 25 17 18 mm 0 5 0 8 1 6 3 2 4 8 6 4 8 0 0 5 0 8 1 6 3 2 4 8 6 4 8 0 1 50 1 32 1 16 1 8 3 16 1 4 5 16 1 50 1 32 1 16 1 8 3 16 1 4 5 16 55 6 6 6 6 6 4 3 6 6 6 6 5...

Страница 11: ...965 0064 016 920 0064 016 950 0064 016 8 0 5 16 18 960 0080 016 960 0080 016 920 0080 016 950 0080 016 mm Fluorel Butyl 1 6 1 16 14 970 0016 016 930 0016 016 3 2 1 8 16 970 0032 016 930 0032 016 4 8 3...

Страница 12: ...E080 024 913 E080 024 902 E080 024 960 E080 K24 965 E080 K24 9 6 3 8 122 910 E096 024 913 E096 024 902 E096 024 9 6 3 8 122 910 H096 024 high flow element 501RL Flow rates Watson Marlow Bioprene and...

Страница 13: ...tion Certificate for each pump returned RGA No 1 Company Address Postcode Telephone Fax Number 2 1 Serial Number a 2 2 Has the Product been used b YES NO c d If yes please complete all the following S...

Отзывы: