Watson Marlow Pumps 501CC Скачать руководство пользователя страница 17

17

Product use and decontamination declaration

In compliance with the 

UK Health & Safety at Work Act

 and the

 Control of Substances

 

Hazardous to Health

Regulations

 you, the user are required to declare the substances which have been in contact with the product(s) you

are returning to Watson-Marlow or any of its subsidiaries or distributors. Failure to do so will cause delays in servicing
the product. Therefore, 

please complete this form

 to ensure that we have the information 

before

 receipt of the

product(s) being returned. 

A FURTHER COPY 

MUST

 BE ATTACHED TO THE OUTSIDE OF THE PACKAGING

CONTAINING THE PRODUCT(S)

You, the user, are responsible for cleaning and decontaminating the

product(s) before returning them.

Please complete a separate Decontamination Certificate for each pump returned.

RGA No:

.......................

1

Company

Address

........................................

Postcode ........................................

Telephone

........................................

Fax Number ....................................

3.4 Cleaning fluid to be used if residue of chemical is found during

2 Product

servicing;

2.1 Serial Number ................................

(a)

2.2 Has the Product been used?

(b) ……………………………………………

YES

     NO

(c) ……………………………………………

(d) ……………………………………………

If yes, please complete all the following

Sections

If no, please complete Section

5 only

3 Details of substances pumped

4  I hereby confirm that the only substances(s) that the equipment
specified has pumped or come into contact with are those named, that the
information given is correct, and the carrier has been informed if the

3.1 Chemical names:

consignment is of a hazardous nature.

(a) ....................................................... 5 Signed ……………………………………………….. ...........

(b) .......................................................

Name …………………………………………………

(c) .......................................................

Position ……………………………………………….

(d) .......................................................

Date …………………………………………………..

 3.2 Precautions to be taken in
handling these substances:

(a) ........................................................

(b) .......................................................................................................

(c) ........................................................

(d) ........................................................

3.3 Action to be taken in the event of human contact:

(a) ………………………………………………………………….

(b) ………………………………………………………………….

(c) ………….………………………………………………………

(d) ………….………………………………………………………

Watson-Marlow Limited   Falmouth   Cornwall   TR11 4RU   England   Tel: 01326 370370   Fax: 01326 376009

Note: To assist us in our servicing
please describe any fault condition you
have witnessed.

Содержание 501CC

Страница 1: ...501CC 501cc gb 02 pdf...

Страница 2: ...2 9 8 501F 501P 501X 501V ATEX 501DF 501DP 501DFX 501DV ATEX II 2 G T4...

Страница 3: ...ll not be binding upon Watson Marlow Limited unless expressly approved in writing by a Director or Manager of Watson Marlow Limited Information for returning pumps Equipment which has been contaminate...

Страница 4: ...s through the gearbox foot mounting holes AC Motor Ensure that mains voltage frequency are in accordance with motor nameplate information Secure protective conductor connections If the motor is runnin...

Страница 5: ...igh air humidity aggressive media and large temperature variations will reduce the interval between lubricant changing intervals Select the correct lubricating oil from the table in the back of this o...

Страница 6: ...r line too small x Restricted exhaust x x Poor lubrication x x x x Jammed machine x x x x Compressor too small x x Compressor too far from unit x x PumpSpecifications Control range See pump specificat...

Страница 7: ...d open the hinged guard and swing out the rotor crank handle until it locks into position Select the length of tubing required noting that approximately 240mm is required for the track systems Fit one...

Страница 8: ...guard After the pump has been started open the delivery clamp for a short time so that the tube can find its natural length The 501RLC pumphead is fitted with four position tube clamps to accommodate...

Страница 9: ...ck 3 FN 2341 Hinge screw 4 MN 0266M Hinge grey 5 MNA0114A Tube clamp assembly 6 FN 2332 Screw 7 FN 0422 Screw x 4 8 MN 0011T Main roller 9 MNA0143A 501RLC Rotor assembly 9 MNA0511A 501RL2C Rotor assem...

Страница 10: ...220 EnergolGR XP 100 Mobil gear 629 Shell Omala Oel 100 Bartran HV15 Mobil DTE 11M Shell Tellus Oel T 15 501F RL 501I RL 501TI RL 100ml 601F R 601I R 601TI R 250ml Technical Data 165 165 English Tube...

Страница 11: ...380 60 600 21 213 0 88 8 9 2 6 26 9 0 91 39 400 85 860 130 1400 210 2100 29 291 1 2 12 3 6 36 12 120 54 540 120 1200 180 1900 290 2900 6 62 0 25 2 6 0 74 7 6 2 6 26 11 120 24 250 38 390 60 620 22 223...

Страница 12: ...0048 016 970 0048 016 920 0048 016 6 4 1 4 17 950 0064 016 970 0064 016 920 0064 016 8 0 5 16 18 950 0080 016 970 0080 016 920 0080 016 501RL2C 2 4mm Product codes mm Marprene Bioprene Pumpsil 0 5 1...

Страница 13: ...13 501RLC Flow rates...

Страница 14: ...14 501F R 501DF R 501FX RL 220 250 340 345 230 75 85 62rpm model 223 rpm model...

Страница 15: ...Sta Pure and Chem Sure are trademarks of W L Gore and Associates Warning These products are not designed for use in and should not be used for patient connected applications The information contained...

Страница 16: ...16...

Страница 17: ...ate for each pump returned RGA No 1 Company Address Postcode Telephone Fax Number 3 4 Cleaning fluid to be used if residue of chemical is found during 2 Product servicing 2 1 Serial Number a 2 2 Has t...

Отзывы: